Datasheet

JS-M
3
ds_61211_0000_en_jsm: 061006J
For Cautions for Use, see Relay Technical Information.
3. Ambient temperature and oprating voltage
range
4. Distribution of pick-up and drop-out voltage
Sample: JSM1-12V-5, 50pcs.
5. Distribution of operate and release time
Sample: JSM1-12V-5, 50pcs.
Coil both side without diode
0
5
10
15
35
30
25
20
40
-40 -20 20 40 60 1000 120
8085
Ambient temperature, °C
Coil applied voltage, VDC
Pick-up voltage
(cold start)
0
30
20
10
40
50
60
70
1.50 0.5 1 2 2.5 3 3.5 4.5 54 5.5 6
Voltage, V
Quantity, n
Pick-up voltage
Drop-out voltage
0
30
20
10
40
50
321.5 2.5 3.5 4.514
Time, ms
Quantity, n
Operate time
Release time
6-(1). Electrical life test (Motor load)
Sample: JSM1-12V-5, 3pcs.
Load: 50A (Inrush), 10A 16V DC (Steady)
Switching frequency: (ON : OFF = 1s : 9s)
Circuit :
Tested sample
M
DC16V
DC12V
0
2
1
3
4
5
6
0510
X
Max.
Min.
Pick-up and drop-out voltage, V
No. of operations,
×
10
4
Contact welding: 0 times
Miscontact: 0 times
Pick-up voltage
Drop-out voltage
X
Max.
Min.
6-(2). Electrical life test (Lamp load)
Sample: JSM1-12V-5, 4pcs.
Load: 55.2A (Inrush), 9.6A 14.5V DC (Steady)
Switching frequency: (ON : OFF = 1s : 3s)
Circuit :
Tested sample
DC14.5V
DC12V
0
2
1
3
4
5
6
0 5 10 15
X
Max.
Min.
Pick-up and drop-out voltage, V
No. of operations,
×
10
4
Contact welding: 0 times
Miscontact: 0 times
Pick-up voltage
Drop-out voltage
X
Max.
Min.