Datasheet
JQ
5
ds_61144_0000_en_jq: 041206D
High capacity type
For Cautions for Use, see Relay Technical Information.
1-(1). Operate & release time (1 Form A type)
Tested sample: JQ1aP-12V-F, 25 pcs.
1-(2). Operate & release time (1 Form C type)
Tested sample: JQ1P-12V-F, 25 pcs.
2. Life curve
Ambient temperature: room temperature
80 100 120 150
2
0
4
6
8
Coil applied voltage, %V
Operate & release time, ms
Operate time
Release time
Min.
Min.
Max.
Max.
80 100 120 150
2
0
4
6
8
Coil applied voltage, %V
Operate & release time, ms
Operate time
Release time
Min.
Min.
Max.
Max.
100
10
1
2046810
Contact current, A
125V AC resistive load
250V AC resistive load
Life,
×
10
4
3-(1). Coil temperature rise (1 Form A type)
Contact carrying current: 5 A, 10 A
Measured portion: Inside the coil
3-(2). Coil temperature rise (1 Form C type)
Contact carrying current: 5 A, 10 A
Measured portion: Inside the coil
100 120 140 160 180
10
20
30
40
50
60
70
0
Coil applied voltage, %V
Temperature rise, °C
10 A at 70°C
10 A at 85°C
5 A at 70°C
5 A at 85°C
Coil applied voltage, %V
Temperature rise,
°
C
100 110 120 130 140 150 160
10
20
30
40
50
60
70
0
10 A at 70°C
10 A at 85°C
5 A at 70°C
5 A at 85°C
4-(1). Ambient temperature characteristics
(1 Form A type)
Tested sample: JQ1aP-24V-F
Contact carrying current: 5 A, 10 A
4-(2). Ambient temperature characteristics
(1 Form C type)
Tested sample: JQ1P-24V-F
Contact carrying current: 5 A, 10 A 1 Allowable ambient temperature against
% coil voltage (max. inside the coil temperature
set as 130°C 266°F) (Carrying current: 5 A)
2 Allowable ambient temperature against
% coil voltage (max. inside the coil temperature
set as 130°C 266°F) (Carrying current: 10 A)
3 Allowable ambient temperature against
% coil voltage (max. inside the coil temperature
set as 115°C 239°F) (Carrying current: 5 A)
4 Allowable ambient temperature against
% coil voltage (max. inside the coil temperature
set as 115°C 239°F) (Carrying current: 10 A)
5 Pick-up voltage with a hot-start condition
of 100%V on the coil (Carrying current: 10 A)
6 Pick-up voltage with a hot-start condition
of 100%V on the coil (Carrying current: 5 A)
7 Pick-up voltage
20 30 40 50 60 70 80 90
0
100
200
300
400
Ambient temperature, °C
Coil applied voltage, %V
1
5
4
7
6
3
2
20 30 40 50 60 70 80 90
0
100
200
300
400
Ambient temperature, °C
Coil applied voltage, %V
1
5
7
6
2
3
4