Datasheet

JQ
4
ds_61144_0000_en_jq: 041206D
REFERENCE DATA
Standard type
Max. switching capacity (1 Form A type) Max. switching capacity (1 Form C type)
AC resistive load (High capacity type)
AC resistive load (Standard type)
1
10 100 277 1,000
10
100
5
Contact voltage, V
Contact current, A
1
10 100 277 1,000
10
100
2
3
5
Contact voltage, V
Contact current, A
AC resistive load
(High capacity type) N.O. side
AC resistive load
(High capacity type)
N.C. side
AC resistive load
(Standard type) N.O. side
AC resistive load
(Standard type)
N.C. side
1-(1). Operate & release time (1 Form A type)
Tested sample: JQ1a-12V-F, 25 pcs.
1-(2). Operate & release time (1 Form C type)
Tested sample: JQ1-24V-F, 25 pcs.
2. Life curve
Ambient temperature: room temperature
80 100 120 150
2
0
4
6
8
Coil applied voltage, %V
Operate & release time, ms
Operate time
Release time
Max.
Max.
Min.
Min.
80 100 120 150
2
0
4
6
8
Coil applied voltage, %V
Operate & release time, ms
Operate time
Release time
Min.
Min.
Max.
Max.
100
10
1
102345
Contact current, A
125V AC resistive load
250V AC resistive load
Life,
×
10
4
3-(1). Coil temperature rise (1 Form A type)
Contact carrying current: 3 A, 5 A
Measured portion: Inside the coil
3-(2). Coil temperature rise (1 Form C type)
Contact carrying current: 3 A, 5 A
Measured portion: Inside the coil
100 110 120 130 140 160 190180170150
10
20
30
40
50
0
Coil applied voltage, %V
Temperature rise, °C
3 A at 85°C
5 A at 85°C
3 A at 70°C
5 A at 70°C
100 110 120 130 140 160150
10
20
30
40
50
60
70
0
Coil applied voltage, %V
Temperature rise,
°
C
3 A at 70°C
5 A at 70°C
5 A at 85°C
3 A at 85°C
4-(1). Ambient temperature characteristics
(1 Form A type)
Tested sample: JQ1a-24V-F
Contact carrying current: 3 A, 5 A
4-(2). Ambient temperature characteristics
(1 Form C type)
Tested sample: JQ1-24V-F
Contact carrying current: 3 A, 5 A 1 Allowable ambient temperature against
% coil voltage (max. inside the coil temperature
set as 130°C 266°F) (Carrying current: 3 A)
2 Allowable ambient temperature against
% coil voltage (max. inside the coil temperature
set as 130°C 266°F) (Carrying current: 5 A)
3 Allowable ambient temperature against
% coil voltage (max. inside the coil temperature
set as 115°C 239°F) (Carrying current: 3 A)
4 Allowable ambient temperature against
% coil voltage (max. inside the coil temperature
set as 115°C 239°F) (Carrying current: 5 A)
5 Pick-up voltage with a hot-start condition
of 100%V on the coil (Carrying current: 5 A)
6 Pick-up voltage with a hot-start condition
of 100%V on the coil (Carrying current: 3 A)
7 Pick-up voltage
20 30 40 50 60 70 80 90
0
100
200
300
400
Ambient temperature, °C
Coil applied voltage, %V
1
5
6
4
7
3
2
20 30 40 50 60 70 80 90
0
100
200
300
400
Ambient temperature, °C
Coil applied voltage, %V
1
3
4
5
7
6
2