Datasheet
JQ
2
ds_61144_0000_en_jq: 041206D
Characteristics
Remarks
* Specifications will vary with foreign standards certification ratings.
*
1
Measurement at same location as “Initial breakdown voltage” section
*
2
Detection current: 10 mA
*
3
Wave is standard shock voltage of ±1.2 × 50μs according to JEC-212-1981
*
4
Excluding contact bounce time
*
5
Measured conditions
*
6
Half-wave pulse of sine wave: 11ms; detection time: 10μs
*
7
Half-wave pulse of sine wave: 6ms
*
8
Detection time: 10μs
*
9
Refer to 6. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT (p. 19, Relay Technical Information).
*
10
When using relays in a high ambient temperature, consider the pick-up voltage rise due to the high temperature (a rise of approx. 0.4% V for each 1°C 33.8°F with
20°C 68°F as a reference) and use a coil impressed voltage that is within the maximum allowable voltage range.
TYPICAL APPLICATIONS
• Air conditioners
• Refrigerators
• Microwave ovens
• Heaters
ORDERING INFORMATION
Max. operating speed 20 cpm
Initial insulation resistance*
1
Min. 1,000 MΩ at 500 V DC
Initial breakdown voltage*
2
Between open contacts
1a: 1,000 Vrms for 1 min.
1c: 750 Vrms for 1 min.
Between contacts and coil 4,000 Vrms for 1 min.
Surge voltage between contact and coil*
3
8,000 V
Operate time*
4
(at nominal voltage) Max. 20 ms
Release time*
4
(at nominal voltage)(without diode) Max. 10 ms
Temperature rise*
5
Max. 45°C
Shock resistance
Functional*
6
Min. 294 m/s
2
{30 G}
Destructive*
7
Min. 980 m/s
2
{100 G}
Vibration resistance
Functional*
8
98 m/s
2
{10 G}, 10 to 55 Hz at double amplitude of 1.6 mm
Destructive 117.6 m/s
2
{12 G}, 10 to 55 Hz at double amplitude of 2.0 mm
Conditions for operation, transport and storage*
9
(Not freezing and condensing at low temperature)
Ambient temp.*
10
–40°C to +85°C –40°F to +185°F
Humidity 5 to 85% R.H.
Unit weight Approx. 7 g .25 oz
Standard type Resistive, nominal voltage applied to the coil. Contact carrying current: 5 A, at 70°C 158°F
High capacity type Resistive, nominal voltage applied to the coil. Contact carrying current: 10 A, at 70°C 158°F
Contact
arrangement
1a: 1 Form A
1: 1 Form C
Nil: Standard
P: High capacity
5, 6, 9, 12, 18, 24, 48* V
Contact capacity
Nil: Class E coil insulation
B: Class B coil insulation
Coil insulation class
F: AgSnO2 type
Contact materialCoil voltage (DC)
UL/CSA, VDE, SEMKO approved type is standard.
* Available only for 1 Form C type
1a P BEx. JQ 12 FV