Datasheet

JQ
6
ds_61B03_en_jq: 201112D
SAFETY STANDARDS
NOTES
For Cautions for Use, see Relay Technical Information.
Item
UL/C-UL (Recognized) CSA (Certified) VDE (Certified) TÜV (Certified) SEMKO (Certified)
File No. Contact rating File No. Contact rating File No. Contact rating File No. Rating File No. Contact rating
Standard type
(5A) 1 Form A
E43028
5A 125V AC
5A 277V AC
5A 30V DC
0.3A 110V DC
1
/10HP 125V
AC
1
/6HP 277V AC
LR26550
5A 125V AC
5A 277V AC
5A 30V DC
0.3A 110V DC
1
/10HP 125V
AC
1
/6HP 277V AC
40011435
5A 250V AC
(cos=0.4)
B 08 09
13461
252
5A 250V AC
(cos=0.4)
5A 30V DC (0ms)
817138 3(2)A 125V AC
2(1)A 250V AC
5A 30V DC
Standard type
(5A) 1 Form C
E43028
5A 125V AC
5A 277V AC
5A 30V DC
0.3A 110V DC
1
/10HP 125V
AC
1
/6HP 277V AC
LR26550
5A 125V AC
5A 277V AC
5A 30V DC
0.3A 110V DC
1
/10HP 125V
AC
1
/6HP 277V AC
40011435
5A 250V AC
(cos=0.4)
(N.O.)
3A 250V AC
(cos=0.4)
(N.C.)
B 08 09
13461
252
5A 250V AC
(cos=0.4)
5A 30V DC (0ms)
817138 3(2)A 125V AC
2(1)A 250V AC
5A 30V DC
High capacity
type
(10A) 1 Form A
E43028 10A 125V AC
8A 277V AC
5A 30V DC
0.3A 110V DC
1
/6HP 125V AC
1
/6HP 277V AC
LR26550 10A 125V AC
8A 277V AC
5A 30V DC
0.3A 110V DC
1
/6HP 125V AC
1
/6HP 277V AC
40011435
10A 250V AC
(cos=0.4)
B 08 09
13461
252
10A 250V AC
(cos=0.4)
5A 30V DC (0ms)
817138 5(3)A 250V AC
5A 30V DC
High capacity
type
(10A) 1 Form C
E43028 10A 125V AC
8A 277V AC
5A 30V DC
0.3A 110V DC
1
/6HP 125V AC
1
/6HP 277V AC
LR26550 10A 125V AC
8A 277V AC
5A 30V DC
0.3A 110V DC
1
/6HP 125V AC
1
/6HP 277V AC
40011435
(N.O.)
10A 250V AC
(cos=0.4)
(N.C.)
3A 250V AC
(cos=0.4)
B 08 09
13461
252
10A 250V AC
(cos=0.4)
5A 30V DC (0ms)
817138 5(3)A 250V AC
5A 30V DC
Note about relay installation orientation
To p
Bottom
When installing with the relay terminals parallel to the ground, the contact terminals at
the bottom and the coil terminals at the top, component friction will occur after
numerous switching actions or due to vibration in the non-excitation state.
Since this may cause the relay to stop functioning when the pick-up voltage increases
even if the nominal voltage is applied, please do not install using this orientation.