Datasheet
JQ
2
ds_61B03_en_jq: 201112D
RATING
1. Coil data
2. Specifications
* Specifications will vary with foreign standards certification ratings.
Notes:
*1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load.
*2. Wave is standard shock voltage of 1.250s according to JEC-212-1981
*3.The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to “6. Usage, Storage and Transport
Conditions“ in AMBIENT ENVIRONMENT section in Relay Technical Information.
*4. When using relays in a high ambient temperature, consider the pick-up voltage rise due to the high temperature (a rise of approx. 0.4% V for each 1C 33.8F with 20C
68F as a reference) and use a coil impressed voltage that is within the maximum applied voltage range.
Contact
arrangement
Nominal coil
voltage
Pick-up voltage
(at 20C 68F)
Drop-out
voltage
(at 20C 68F)
Nominal operating
current
[10%] (at 20C 68F)
Coil resistance
[10%] (at 20C 68F)
Nominal operating
power
(at 20C 68F)
Max. applied voltage
1 Form A
5V DC
Standard type:
75%V or less of
nominal voltage (Initial)
High capacity type:
80%V or less of
nominal voltage (Initial)
5%V or more of
nominal voltage
(Initial)
40.0mA 125
200mW
180% of nominal voltage
(at 20C 68
F)
130% of nominal voltage
(at 70C 158F)
[When using relays at
85C 185F, see Notes*4]
6V DC 33.3mA 180
9V DC 22.2mA 405
12V DC 16.7mA 720
18V DC 11.1mA 1,620
24V DC 8.3mA 2,880
1 Form C
5V DC
Standard type:
75%V or less of
nominal voltage (Initial)
High capacity type:
80%V or less of
nominal voltage (Initial)
5%V or more of
nominal voltage
(Initial)
80 mA 62.5
400mW
150% of nominal voltage
(at 20C 68F)
110% of nominal voltage
(at 70C 158F)
[When using relays at
85C 185F, see Notes*4]
6V DC 66.7mA 90
9V DC 44.4mA 202.5
12V DC 33.3mA 360
18V DC 22.2mA 810
24V DC 16.7mA 1,440
48V DC 8.3mA 5,760
Characteristics Item
Specifications
Standard type High capacity type
Contact
Arrangement 1 Form A 1 Form C 1 Form A 1 Form C
Contact resistance (Initial) Max. 100m (By voltage drop 6 V DC 1 A)
Contact material AgSnO
2 type
Rating
Nominal switching capacity (resistive load)
5 A 125 V AC,
2 A 250 V AC,
5 A 30 V DC
N.O. side:
5 A 125 V AC,
2 A 250 V AC,
3 A 30 V AC
N.C. side:
2 A 125 V AC,
1 A 250 V AC,
1 A 30 V DC
10 A 125 V AC,
5 A 250 V AC,
5 A 30 V DC
N.O. side:
10 A 125 V AC,
5 A 250 V AC,
5 A 30 V AC
N.C. side:
3 A 125 V AC,
2 A 250 V AC,
1 A 30 V DC
Max. switching power (resistive load) 625 VA, 150 W
N.O. side:
625 VA, 90 W
N.C. side:
250 VA, 30 W
1,250 V AC, 150 W
N.O. side:
1,250 VA, 150 W
N.C. side:
500 V AC, 30 W
Max. switching voltage 250 V AC, 110 V DC (0.3A)
Max. switching current N.O.: 5 A, N.C.: 2 A N.O.: 10 A, N.C.: 3 A
Nominal operating power 200 mW 400 mW 200 mW 400 mW
Min. switching capacity (reference value)*
1
100 mA, 5 V DC
Electrical
characteristics
Insulation resistance (Initial) Min. 1,000 M (at 500 V DC) Measurement at same location as “Breakdown voltage” section.
Breakdown voltage
(Initial)
Between open contacts 1,000 Vrms for 1 min. 750 Vrms for 1 min. 1,000 Vrms for 1 min. 750 Vrms for 1 min.
Between contact and coil 4,000 Vrms for 1 min. (Detection current: 10 mA)
Temperature rise (coil)
Max. 45C 113F
(By resistive method, nominal coil voltage
applied to the coil; contact carrying current:
5A, at 70C 158F)
Max. 45C 113F
(By resistive method, nominal coil voltage
applied to the coil; contact carrying current:
10A, at 70C 158F)
Surge breakdown voltage*
2
(Between contact and coil) (Initial)
8,000 V
Operate time (at nominal voltage) (at 20C 68F)
(Initial)
Max. 20 ms (excluding contact bounce time.)
Release time (at nominal voltage) (at 20C 68F)
(Initial)
Max. 10 ms (excluding contact bounce time) (Without diode)
Mechanical
characteristics
Shock resistance
Functional 294 m/s
2
(Half-wave pulse of sine wave: 11 ms; detection time: 10s.)
Destructive 980 m/s
2
(Half-wave pulse of sine wave: 6 ms.)
Vibration resistance
Functional 10 to 55 Hz at double amplitude of 1.6 mm (Detection time: 10s.)
Destructive 10 to 55 Hz at double amplitude of 2.0 mm
Expected life Mechanical (at 180 times/min.) Min. 10
7
Conditions
Conditions for operation, transport and storage*
3
Ambient temperature: –40C to +70C –40F to +158F (class E insulation),
–40C to +85C –40F to +185F*
4
(class B insulation)
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Max. operating speed 20 times/min. (at nominal switching capacity)
Unit weight Approx. 7 g .25 oz