GENERAL DESCRIPTION
ICX-35-200 ICX35/May/1999 75
Section 200 - General Description Chapter 6 - Specifications
Overview
This chapter provides detailed lists of all system specifications in an easy-to-follow table format.
Note: The following specifications are subject to change without notice.
Electrical Characteristics
Power Supply
Battery Backup
Equipment Specification/Requirements
All ICX Cabinets 100-240 volts AC + 10% 60 Hz
Primary Power -
Input @ AC:
AC Frequency:
Watts per cabinet (continuous):
Wats for 6-cabinet system (continuous):
85 to 138 volts AC
50/60 Hz
360 watts
2,160 watts
Maximum Peak AC Input Current -
1 cabinet:
2 cabinets:
3 cabinets:
4 cabinets:
5 cabinets:
6 cabinets:
3.3 amps
6.6 amps
9.9 amps
13.2 amps
16.5 amps
19.8 amps
DC Voltage Output Specification: –24 volts DC (–26.0 to –27.6 volts DC)
+5 volts DC (+4.9 to +5.3 volts DC)
AEC (8-circuit card that supports single-line devices
such as rotary and DTMF standard phones; FAX
machines; dictation equipment; etc.) -
Ring Voltage:
Ringing Capability:
150 volts p-p
2.0 REN per circuit
Traffic Rating Characteristics: 6 ACS per station system-wide
ICX key telephones 3 watts maximum (powered from the ICX)
Equipment Specification
Battery Pack: (Part No. VB-44025)
Capacity (with maximum traffic): 30 minutes
Battery Charger Characteristics -
Charger:
Nominal Voltage:
Battery Discharge Cut-Off Voltage:
Floating charge
27.2 volts
21.0 + 0.3 volts DC
CHAPTER 6 - SPECIFICATIONS