Video Multiplexer Operating Instructions Model No. LOCK POWER ALARM RESET MULTI MULTI SCREEN SCREEN SELECT SPOT SEQUENCET CAMERA/PRE SET POSITION 1 2 3 4 5 6 7 8 ON OFF VCR CAM WJ-FS616C 9 10 11 12 13 14 15 16 PUSH OPEN Digital Video Mul tiplexer WJ-FS 616C Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use.
Caution: Before attempting to connect or operate this product, please read the label on the bottom. CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). For U.S.A NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.
IMPORTANT SAFETY INSTRUCTIONS 1) Read these instructions. 2) Keep these instructions. 3) Heed all warnings. 4) Follow all instructions. 5) Do not use this apparatus near water. 6) Clean only with dry cloth. 7) Do not block any ventilation openings. Install in accordance with the manufacturer's instructions. 8) Do not use near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
CONTENTS IMPORTANT SAFETY INSTRUCTIONS ............................ 3 PREFACE .......................................................................... 5 FEATURES ........................................................................ 5 PRECAUTIONS ................................................................. 6 MAJOR OPERATING CONTROLS AND THEIR FUNCTIONS .......................................................... 7 ■ Front View ..................................................................
PREFACE The WJ-FS616C Video Multiplexer is designed to multiplex the field signals from video cameras and record the camera images on a time lapse VCR. Up to 16 cameras can be connected to the unit for monitoring images in multiscreen, sequence, freeze or electronic zoom mode on a video monitor screen. The WJ-FS616C Video Multiplexer allows you to control camera functions such as lens focussing, zooming, and iris, positioning of the pan/tilt head, etc.
PRECAUTIONS • Refer all work related to the installation of this product to qualified service personnel or system installers. • Do not block the ventilation opening or slots on the cover. To prevent the appliance from overheating, place it at least 5 cm (2 inches) away from the wall. • Do not drop metallic parts through slots. This could permanently damage the appliance. Turn the power off immediately and contact qualified service personnel for service. • Do not attempt to disassemble the appliance.
MAJOR OPERATING CONTROLS AND THEIR FUNCTIONS ■ Front View q w e rt y u i o !1 16 ALARM LOCK POWER RESET MULTI MULTISCREEN SCREEN SELECT SPOT SEQUENCE VCR CAM ON OFF CAMERA/PRESET POSITION PUSH OPEN 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Digital Video Multiplexer WJ-FS C !0 @1 #1 UP FUNCTION CURSOR / CAMERA CONTOROL IRIS CLOSE PRE-POSI LEFT HOME/SET EL-ZOOM DOWN AUTO @4 @5 @6 @7 @8 @9 #0 q Power Switch (POWER ON/OFF) This switch turns the power of the video multi
t Spot Monitor Button (SPOT) This button is used to operate the spot monitor connected to the SPOT OUT connector on the rear of the video multiplexer. The indicator (Green) in the button lights to indicate that the spot monitor is selected, and enables control of the monitor. y Multiscreen Monitor Button (MULTISCREEN) This button is used to operate the multiscreen monitor connected to the MULTISCREEN OUT connector on the rear of the video multiplexer.
@6 Direction Buttons (UP/DOWN/LEFT/RIGHT) These buttons are used to manually operate the Pan/Tilt Head, move the cursor position in the setup menu of the video multiplexer, or to select an area for Electric Zooming. UP: DOWN: LEFT: RIGHT: Upward Downward Left Right @7 Auto Button (AUTO) This button is used to activate the auto panning function if the camera is equipped with the specific future. @8 Iris Buttons (IRIS, CLOSE/OPEN) Close or open the lens iris of cameras equipped with the specified lens.
■ Rear View $3 RS485 $4 $5 TERM. LINE SELECT OFF A B T $2 16 15 G N D A B R 14 ON 2 4 $6 $7 CAMERA SW IN GENLOCK IN (VS) $8 $9 VIDEO IN %1 PLAY IN REC OUT SPOT OUT %0 S–VIDEO VIDEO S–VIDEO 2 1 MULTISCREEN OUT VIDEO G N D 12 11 10 9 8 7 6 5 4 3 REMOTE DATA OUT IN TERM.
%6 Signal Ground Terminal (SIGNAL GND) %7 Data Termination Switch (TERM., OFF/ON) This switch is used to enable termination of the video multiplexer’s data port. %8 Data Port (DATA, OUT/IN) These ports are used to exchange control data with the specified system controller or a PC in a system.
INSTALLATION The installations described below should be made by the qualified service personnel or system installers. 4. Remove the one screw shown below. Then turn over the printed circuit board with the front side up. ■ Installing the WV-PB6164 Data Multiplex Boards When controlling the camera with the multiplexed control data by connecting a coaxial cable, the WV-PB6164 Data Multiplex Board must be installed in the video multiplexer.
6. Set the jumper connector, that is located at the top left of the board, to the position shown below where the board is installed. Jumper Connector ■ Tally Output Setting Allows you to use the Alarm Input terminal on the ALARM/REMOTE port as Tally Output terminal by changing two internal connections. It is enabled use that mingles alarm input and tally output. 1. Disassemble the video multiplexer as described for installing the Data Multiplex Boards on page 12.
■ DIP Switch Setting ● Alarm Output Setting The following settings let you set the polarities of alarm output, alarm reset output, and alarm & SW output on the ALARM/REMOTE port. 1. Disassemble the video multiplexer as described for installing the Data Multiplex Boards on page 12. 0/5V O.C SW3 : Alarm Output SW5 2. Set switches (SW3/SW4/SW5) on the board to the required position either Open Collector (O.C) or Pulse (0/5V) for alarm control signals.
■ Mounting into the Rack The video multiplexer can be mounted into the rack as described below. 1. Remove the four rubber feet by removing the four screws on the bottom of the video multiplexer. 2. Place the rack mounting brackets on both sides of the video multiplexer and tighten with the four supplied screws (M4 X10). 3. Install the video multiplexer with the rack mounting brackets in the rack securing it with four screws (procured locally).
CONNECTIONS Shown below is an example of a basic system connection.
■ Connection with the Camera Sites For cameras equipped with RS-485 communication facility, connect the RS-485 cable as follows. Note: If you use cables assembled from locally procured materials, it is important that only high quality, data grade cable, suitable for RS-485 communication (shielded 2-wire twisted pair cable) is used, BELDEN 9406 or equivalent. Low grade cable will result in unstable operation of the system.
■ Connections for RS-485 type camera There are two options to connect the camera with the multiplexer, depending on the distance between them. For data multiplexed type cameras, a maximum distance of 900 meters (3 000 ft) is the limit for using coaxial cable such as RG-59/U, BELDEN 9259 or equivalent. If more distance is required, use cameras and multiplexer with RS-485 communication feature. This will lower signal loss and extend the distance as video signal and data are transmitted separately.
■ Connection with the Monitors Connect the Monitors to the SPOT OUT connector and MULTISCREEN OUT connector on the rear of the video multiplexer with the coaxial cable. Video Multiplexer WJ-FS616C SPOT OUT IN MULTISCREEN OUT VIDEO S–VIDEO ■ Connection with the PC There are two options to communicate with the PC, the first is using RS-232C port and the second is via DATA port.
■ Connection with Alarm Sensors Connect the sensor switches to the ALARM/REMOTE port on the rear of the video multiplexer as shown in the example below. ALARM/REMOTE 1 Pin No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 SW16 GND SW2 SW1 37 19 Designation Function Electronic Zoom Sequence Spot Alarm/Remote Select Input Sequence SW for Spot Output Not Used Alarm Recover Input Alarm Output Alarm 16 Alarm 14 Ground Alarm 11 Alarm 9 Alarm 8 Alarm 6 Ground Alarm 3 Alarm 1 Pin No.
MONITORS AND DISPLAYS ■ Spot and Multiscreen Monitor The WJ-FS616C video multiplexer can be connected to two monitors. The monitor displays the video signal according to the connection made, as shown below. Spot Monitor: The monitor that is connected to the SPOT OUT connector on the rear of the video multiplexer. It only displays the camera input in single spot or single sequence. Displaying the VCR playback is disabled.
■ Connection with the Time Lapse VCR Connect the time lapse VCR as shown in the example below.
SETUP PROCEDURES 23
SETUP MENU The setup menu provides a way for controlling functions that are not available by a direct operation. ■ Displaying the SETUP MENU To display the setup menu follow the procedure below. 1. Confirm that the camera and peripherals are connected correctly and securely and all components are turned on. 2. Press the [SET UP/ESC] button for 2 seconds or more. The WJ-FS616C SETUP MENU appears on the screen of the spot and multiscreen monitors as shown in the figure.
■ Programming Setup Menu As shown below, the SETUP MENU has nine main submenus: Alarm Setup, Multiscreen Output Setup, Spot Output Setup, Record Output Setup, Multiscreen 2 Output Setup, System Setup, Camera Download, Camera Upload and All Reset. Six of these submenus; Alarm Setup, Multiscreen Output Setup, Spot Output Setup, Record Output Setup, Multiscreen 2 Output Setup and System Setup are further divided into additional submenus.
ALARM SETUP The procedure described below let you set the modes when an alarm is received. Move the cursor to ALARM SETUP in the SETUP MENU by pressing the C or D button and then press the [HOME/SET] button. The ALARM SETUP menu as shown in the figure appears on the monitor screen. 5. Press the [SET UP/ESC] button to return to the previous ALARM SETUP menu.
■ Camera Site Alarm ■ Alarm Display on the Monitors This item lets you enable or disable the camera site alarm function. This item lets you enable or disable alarm display on the spot and multiscreen monitors. 1. Move the cursor to the CAM SITE ALM parameter by pressing the C or D button. 1. Move the cursor to the ALM DISPLAY parameter. 2. Select either ON or OFF. 2 Select ON or OFF by pressing the A or B button. ON: Enables camera site alarm function. OFF: Disables camera site alarm function.
■ Alarm Mode on the Multiscreen Monitor This item lets you select the mode for displaying an alarm on the multiscreen monitor. ■ Alarm Mode on the Spot Monitor This item lets you select the mode for displaying an alarm on the spot monitor. 1. Move the cursor to the ALM MODE-SPT parameter. 1. Move the cursor to the ALM MODE-MLT parameter. 2. Select the desired mode. 2. Select the desired mode. ALM-LINK: Switches screen to the camera image of the corresponding channel with an alarm title superimposed.
MULTISCREEN OUTPUT SETUP The procedure described below let you determine the display mode of the multiscreen monitor. WJ-FS616C SETUP MENU ALARM SETUP * MULTI OUTPUT SETUP * SPOT OUTPUT SETUP * REC/MULTI2 REC OUTPUT * SYSTEM SETUP * CAM DOWNLOAD NO CAM UPLOAD NO ALL RESET SELECT * ■ Clock Display This item lets you enable or disable the clock display on the multiscreen monitor. 1. Move the cursor to the CLOCK DISPLAY parameter. 2. Select either ON or OFF. ON: Enables clock display on the monitor screen.
■ Camera Display Position Setting ■ Secret View This item lets you assign the position where the camera image will be displayed on the multiscreen monitor. When the camera image is displayed in the spot mode on the spot monitor, the multiscreen monitor is enabled to skip the step in sequence or display a blackout in multiscreen for that selected channel image. This function is called Secret View and the item lets you enable or disable this function on the multiscreen monitor. 1.
SPOT OUTPUT SETUP The procedure described below let you determine the display mode of the spot monitor. ■ Camera Title Display This item lets you enable or disable display of the camera title on the spot monitor. WJ-FS616C SETUP MENU ALARM SETUP * MULTI OUTPUT SETUP * SPOT OUTPUT SETUP * REC/MULTI2 REC OUTPUT * SYSTEM SETUP * CAM DOWNLOAD NO CAM UPLOAD NO ALL RESET SELECT * Move the cursor to SPOT OUTPUT SETUP in the SETUP MENU, and then press the [HOME/SET] button.
RECORD OR MULTISCREEN 2 OUTPUT SETUP The procedure described below let you determine the mode for the REC OUT connector on the rear of the video multiplexer. As described before, this output can be used for recording images on the time lapse VCR or monitoring images as multiscreen 2 monitor.
● Dynamic Recording ● Recording Mode Setup This item lets you select the cameras for dynamic recording mode in non-alarm condition. If five or more cameras are connected to the video multiplexer, the channels selected for dynamic recording are recorded with priority. This item lets you select a recording mode on the time lapse VCR. 1. Move the cursor to DYNAMIC REC SETUP by pressing the C or D button and then press the [HOME/SET] button.
3. Select the desired switching timing indicated as the field interval (4 to 999) by pressing the A or B button. Notes: • Numbers can also be input directly with the Camera Number buttons (1 - 10). • Refer to the operating instructions of the VCR for switching timing. When MODE9 is selected in this table, select EXT1 or EXT4 by pressing the A or B button. EXT1: Enables spot image recording on the VCR. EXT4: Enables quad images recording on the VCR.
● Camera Display Position This item lets you select the position where the camera images will be displayed on the multiscreen 2 monitor. 1. Move the cursor to DISPLAY POSITION, then press the [HOME/SET] button. The table shown in the figure appears on the monitor. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 2. Move the cursor to the desired channel number by pressing the C or D button. 3. Select the numbers of the cameras to be displayed by pressing the A or B button.
SYSTEM SETUP The procedure described below let you determine the system designation and display the system status. ■ Clock Setup This item lets you set the current time and date. WJ-FS616C SETUP MENU ALARM SETUP * MULTI OUTPUT SETUP * SPOT OUTPUT SETUP * REC/MULTI2 REC OUTPUT * SYSTEM SETUP * 1. Move the cursor to CLOCK SETUP in the SYSTEM SETUP menu and then press the [HOME/SET] button. The cursor moves to the right editing area. 2. Select the month by pressing the A or B button.
■ Camera Title Setup This item lets you edit the camera title to be displayed on the monitor screen. Up to 8 alphanumeric characters can be displayed on the monitor. 1. Move the cursor to TITLE SETUP in the SYSTEM SETUP menu by pressing the C or D button, then press the [HOME/SET] button. The TITLE SETUP menu shown in the figure appears on the monitor screen. 8. Press the [FUNCTION] button to display the next page, then press this button again to return to the previous page. 9.
2. Select SEQ1 and then press the [HOME/SET] button. The SEQ1 SETUP menu shown in the figure appears on the monitor screen. SEQ1(SPOT-SEQUENCE)SETUP 1 OF 2 AUTO SKIP OFF DWELL TIME 2SEC STEP 1 2 3 4 5 6 7 8 CAM PRE TIME 1CH - 2SEC 2CH - 2SEC 3CH - 2SEC 4CH - 2SEC 5CH - 2SEC 6CH - 2SEC 7CH - 2SEC 8CH - 2SEC 2. Select the desired preset position number for the camera in the PRE column by pressing the - or + button.
4. After finishing the settings, press the [SET UP/ESC] button to execute the settings and return to the previous SYSTEM SETUP menu. ● Multi Sequence (SEQ2, SEQ3) This item lets you program or edit a Multi Sequence. Up to 5 steps can be assigned in the table shown below. You can also enable the auto skip function to skip any steps where no video signal is present. The duration of each step is determined by the dwell time setting.
Preset Position 1. Move the cursor to the PRE column you want to edit for the area number by pressing the C, D, A or B button. 2. Select the desired preset position number for the camera in the PRE column by pressing the - or + button. 3. Repeat steps 1 and 2 above to assign other area numbers. Notes: • When the STEP parameter in this table is on PLAY, it is not possible to select a preset position in the PRE column. • It is possible to assign the same camera channel to multiple area numbers within a step.
■ Cable Compensation/VD2/Data This item lets you select the optimum setting for the cableloss compensator and whether to supply the VD2 (sync) signal or control data to the camera. Note: These settings will work only for the input channels that have the multiplex feature with the Data Multiplex Board WV-BP6164 installed. The boards are installed for input channels 1 through 4 at the factory. You can install boards for other channels. For installations, see page 12. 1.
4. Select the preset position number to be assigned in the PRE column by pressing the - or + button. 5. Repeat steps 2 to 4 above to assign other terminal numbers. Note: The same channel number can be assigned to multiple alarm terminals. In this case, different preset positions can be assigned, but when alarm occurs at these positions, the camera movHes to the preset position where the most recent alarm occurred. 6.
5. Select the desired waiting time for WAIT TIME by pressing the - or + button. This item lets you set the waiting time to retry if there is no response from the connected device. OFF: Selects no retry. 100 – 1000: Selects a waiting time in milli-seconds. 6. Select a number of data bit, 7 or 8, for DATA BIT by pressing the - or + button. 7. Select the parity check mode for PARITY by pressing the - or + button.
■ Password This item lets you select whether to permit free or limited access to the setup menus. When PASSWORD is set to ON, the operator must enter the password to access the setup menus. 1. Move the cursor to the PASSWORD parameter in the SYSTEM SETUP menu. 2. Select either ON or OFF by pressing the A or B button. ON: Enables limited access to the menus. OFF: Enables freely access to the menus. The factory default setting is OFF.
OTHER SETUP MENUS ■ Camera Download ■ Camera Upload This item lets you save the camera setup data into the memory of the video multiplexer. If the setup contents of the camera should be lost due to malfunctioning or replacement of a camera, you can simply reload the data stored in the video multiplexer. This item lets you upload camera setup data from the video multiplexer’s memory to a camera. 1. Move the cursor to the CAM DOWNLOAD parameter in the SETUP MENU. 2.
■ All Reset This item lets you restore the factory settings without having to go through each individual menu. 1. Move the cursor to ALL RESET SELECT in the SETUP MENU, then press the [HOME/SET] button. The ALL RESET SELECT menu shown in the figure appears on the monitor screen. ALL RESET SELECT ALL-RESET NO CAUTION:ALL ALARM INPUTS HAVE BEEN DISABLED. 2. Select “YES” by pressing the A or B button. 3. Press the [HOME/SET] button to execute the all reset function. 4.
OPERATING PROCEDURES 47
CONTROLLING THE VIDEO INPUT AND MONITORS Before starting the following procedures, all system components should be turned on. Then set the LOCK switch to the OFF position. Controlling the Spot Monitor The operations described below are available on the spot monitor. ■ Selecting the Spot Monitor 1. Select the spot monitor by pressing the [SPOT] button. The indicator (green) in the button is on to indicate the spot monitor is selected.
Controlling the Multiscreen Monitor The indicator in the selected button lights and the camera image corresponding to the button appears on the monitor screen. The operations described below are available on the multiscreen monitor. Note: We recommend using the spot monitor in single spot for preventing image disturbance when displaying noninterlace images. 2 ■ Selecting the Multiscreen Monitor 1. Select the multiscreen monitor by pressing the [MULTISCREEN] button repeatedly.
3. To cancel this mode, press the [STILL] button to return to the image previously shown. The indicator in the button goes off. ● Zooming Single Spot (Live) While the image on the monitor screen is displayed in single spot mode, the image can be zoomed followed the procedure below. ● Multiscreen Spot (Live) The monitor can display the camera images on a 4, 7, 9, 10, 13 and 16 multiscreen shown below. 1.
2. Press the [STILL] button. The indicator in the button lights. 3. Select an image to be frozen on the monitor by pressing a [1 – 16] button. The indicator in the selected button start blink and the camera image corresponding to the button is displayed in freeze on the monitor screen.
2. Select the VCR playback mode (indicator on) by pressing the [VCR/CAM] button. VCR CAM 3. In this condition, select the images to be displayed on the monitor screen followed the procedure shown below. Notes: • This unit does not reproduce a clear image in reverse playback. • The playback image may be skewed (horizontally distorted) in the upper portion of the monitor screen depending on the selected playback mode.
● Zooming Single Spot (Playback) ● Freezing Multiscreen Spot (Playback) While the image on the monitor screen is displayed in single spot mode, the image can be zoomed followed the procedure below. The monitor can display the freeze playback images on a 4, 9 and 16 multiscreen shown below. 1. Select an image to be zoomed on the monitor by pressing a [1 – 16] button. The indicator in the selected button lights and the camera image corresponding to the button appears on the monitor screen. 2.
3. To return to single spot monitoring, select an image to be displayed by pressing a [1 – 16] button. Or to return to screen segments display, press the [MULTISCREEN SELECT] button. Note: The same channel cannot be displayed in multiple segments. If this attempt is made, only the image of the channel with the lowest number is displayed; the other segments appear black out. 3. Press the [FUNCTION] button. The indicator in the button starts to blink. FUNCTION 4.
● Freezing Multiscreen Spot (Live Images with a Playback Image) The monitor can display the freeze camera images on a 4-, 7-, 10- or 13-segment multiscreen while cameras with playback images are displayed. 1. Repeat steps 1 to 4 referring the procedure in the Multiscreen Spot. 2. Press the [STILL] button. The indicator in the button lights. 3. Select a camera image to be frozen on the monitor by pressing a [1 – 16] button.
CAMERA CONTROL FUNCTION The camera control is only available while the camera image is displayed in single spot on the selected monitor screen and the LOCK switch is in OFF position. ■ Camera Selection 1. Select an either spot or multiscreen monitor by pressing the [SPOT] or [MULTISCREEN] button. The indicator in the selected button is on. Pressing both of these buttons simultaneously will automatically set the lens focus, if the specified camera with auto focus feature is used. 3.
● Pan/Tilt Control (Preset Operation) The following function requires the use of cameras equipped with the specific feature. Note: Select only preset position numbers 1 to 16. 1. Select the desired monitor and camera referring to the Camera Selection procedure described above. 2. Press the [PRE-POSI] button. 3. To cancel the auto panning function, press one of the Direction buttons.
7. Press the [SET UP/ESC] button, while holding the [FUNCTION] button, to exit from the setup mode or menu. FUNCTION SET UP/ESC Note: Refer to the operating instructions of the selected camera for further details. Caution: Camera addresses are important for RS-485 type cameras. • Do not use addresses other than 1 through 16 for individual cameras. (“17” is not allowed) • Do not set a single address for more than one camera in an RS-485 chain.
ALARM CONTROL FUNCTION The alarm function activates the warning alarm status, when an externally connected alarm sensor is turned on. Described below is an example of an alarm status activation. ■ Alarm Input ■ Alarm Operation When an alarm signal is received, the multiplexer, the Record Output, Spot Output and Multiscreen Output of the multiplexer are activated as shown below. Refer to the ALARM SETUP menu of the WJ-FS616C SETUP MENU for further settings.
● Multiscreen Output The alarmed input image and alarm display are displayed on the multiscreen monitor as shown below. Described below are several examples; the selected mode varies, depending on the menu setting. • Alarm Link Mode • The image of the alarmed camera is displayed in single spot mode on the monitor. The indicator in the corresponding CAMERA button blinks.
■ Alarm Reset ■ Example of Using Multiscreen 2 Monitor ● Manual Reset When an alarm is activated, the ALARM indicator blinks. The indicator keeps blinking until all alarms are cleared by pressing the [ALARM RESET] button. The blinking or lit indicator goes off. The figure below shows an example of how alarm is displayed when a Multiscreen 2 Monitor is connected to the REC OUT connector. (selects ALM-LINK for ALM MODE-MLT in the ALARM SETUP menu.
■ Alarm Suspension This function disables activation of the alarm link and instead enables storing of any alarm activated in the alarm log. It is used to suspend the alarm link during camera setup. To suspend the alarm: 1. Press the [RESET] and [SPOT] buttons at the time for 2 seconds or more to suspend the alarm. The indicator in the [RESET] button lights. RESET SPOT 2. Press the [RESET] button to reset the alarm suspension. The indicator in the [RESET] button goes off.
OTHER FUNCTION ■ Recording on the Time Lapse VCR The following selections are made in the WJ-FS616C SETUP MENU described previously. Refer to the Recording Mode Setup on page 33 for further details. 1. Check the selected recording mode (MODE 0 - MODE 9). MODE 0: Normal Mode (Real Time) MODE 1 - 9: Time Lapse Mode (Linear Mode) If MODE 9 is selected, check the image (spot or quad) to be recorded on the VCR. 2. Press the Record button of the VCR to begin recording.
OPERATING PROCEDURES (with WV-CU550C) 65
SYSTEM CONTROLLER WV-CU550C The WJ-FS616C video multiplexer can be controlled from the WV-CU550C system controller. The following procedures apply when the WV-CU550C system controller is connected to the system. ■ Major Operating Controls and Their Functions Note: When using this controller in combination with the WJ-FS616C, cover the panel of the controller with the panel templates provided.
q Alarm Indicator (ALARM) This indicator (Red) lights to indicate that an alarm condition exists. It goes off when the alarm is reset automatically. To turn the ALARM indicator off of the multiplexer, press the RESET button. w Busy Indicator (BUSY) This indicator lights to indicate that the system is locked by PC command. While this indicator is lit, control from the video multiplexer and system controller is disabled.
!6 Function button (FUNCTION) This button is used to display the camera images with a VCR playback image on the multiscreen monitor. While displaying the setup menu on the monitor, pressing this button will select the next page of the setup menu. !7 Auto/Increment button (AUTO/+ ) This button is used to activate the auto panning function if the camera is equipped with the specific future.
■ Installations The installations described below should be made by qualified service personnel or system installers. ● Modifying the Front Panel Peel the tape off the supplied panel templates, then attach them on the front panel of the system controller. • Setting the Termination and Controller Unit Number The Termination switch and the Controller Unit Number switch are located on the rear of the system controller.
SETUP MENU OPERATIONS (WITH WV-CU550C) During setup of the WJ-FS616C with the WV-CU550C system controller, the following buttons and keys of the system controller correspond with those of the WJ-FS616C as shown below. WJ-FS616C WV-CU550C SET UP SET UP/ESC Function Display the SETUP MENU or escape from the menu. Press 2 sec or more. UP UP Move the cursor or select the mode or parameter.
FUNCTION OPERATIONS (WITH WV-CU550C) When operating the video multiplexer with the WV-CU550C system controller, the following buttons and keys of the system controller correspond with those of the video multiplexer. LEFT To select a monitor and camera, follow the procedure shown below.
Camera Control Function The camera control is only available while the camera image is displayed in single spot on the selected monitor screen. 3. Press the [ZOOM] button to adjust the lens zoom to achieve the desired image while observing the active monitor. Press this button to the [TELE] position to optically bring an object closer. Pressing to the [WIDE] position has the reverse effect.
3. Press the [CAM(SET)] key to move the pan/tilt head to the preset position on the active monitor. CAMERA SET ON REV ● Pan/Tilt Control (Home Position) The following function requires the use of cameras equipped with the specific feature. 2. Press the [HOME/–] button to move the camera to the home position on the active monitor. HOME/– AUX1 ● Pan/Tilt Control (Auto Panning ) The following function requires the use of cameras equipped with the specific feature. 1.
● Auxiliary Control Alarm Control Function The following function is available only with a system that includes WV-RC100 or WV-RC150 Receivers. 1. Select the desired monitor and camera referring to the Camera Selection procedure described above. 2. While the ALT indicator is on, press the [HOME/–] or [AUTO/+] button to toggle the user’s auxiliary switch in the receiver on and off.
SYSTEM EXPANSION The system shown below is an example of the expansion capabilities of the WJ-FS616C video multiplexer. Up to four video multiplexers can be connected to expand the camera inputs.
■ Connections For example, press the keys shown below. In this type of installation, only one video multiplexer is connected directly to the system controller by a control cable. The rest of the video multiplexers are connected to the system controller in a daisy-chain type connection. Refer to the connections and data port settings shown below.
● Application 2 The camera images in the Local Site (Unit 2) can be displayed on the multiscreen monitor in the Main Site (Unit 1) by connecting a coaxial cable shown below. Video Multiplexer REC OUT VIDEO S–VIDEO Local Site Coaxial Cable RG-59/U less than 250m (800 ft) Video Multiplexer PLAY IN VIDEO S–VIDEO MULTISCREEN OUT VIDEO S–VIDEO Main Site Multiscreen Monitor Live 1-16ch Playback 1-16ch For Local Site • Confirm that the REC MODE SETUP in the REC OUTPUT SETUP menu (page 33) is set to MODE 0.
APPENDIX This Appendix details the elements for communication between the Video Multiplexer and the personal computer. For BAUD RATE, DATA BIT, STOP BIT and PARITY settings, see page 42 COM PORT SETUP menu. ● Communication Protocol 1. Transmission Command The PC sends messages to operate the Multiplexer in the format shown below. Also refer to the command table shown later.
● Command Table (1) Operation Control Item Transmission Command (ASCII) Response Command (ASCII) Parameter (ASCII) Monitor Select OMS : m OMS m=0 m=1 m=2 Spot Monitor Multiscreen Monitor Multiscreen 2 Monitor VCR/Camera Select OVC : m OVC m=0 m=1 Camera Mode VCR Mode OST m=0 Still OFF m=1 Still ON nn=00 All video channels specify nn=01 - 16 Camera Number Quad m=1 9 divide m=3 13 divide m=5 No.
(3) Cursor Control Item Cursor Movement Select Parameter Transmission Command (ASCII) Response Command (ASCII) DCR : mm DCR Parameter (ASCII) mm=UU mm=DD mm=RR mm=LL mm=BB mm=ES mm=IC mm=DC mm=FF Move Upward Move Downward Move to Right Move to Left Move to lower layer Move to upper layer Item decision (partial) Select parameter (+) Select parameter (–) Select page mm=UR mm=UL mm=DR mm=DL Move to Upper-Right Move to Upper-Left Move to Lower-Right Move to Lower-Left *2 *2 The parameter valid on the m
Examples of response No.
SPECIFICATIONS Power Source: Power Consumption: Camera Input (1-16): Camera Output (1-16): Spot Output: Multiscreen Output: Recording Output: Playback Input: Alarm/Remote Control: VCR Control (RS-232C): VCR Control (Wired): Ambient Operating Temperature: Ambient Operating Humidity: Dimensions: Weight: 120 V AC 60 Hz 50 W 1.0 V[p-p] /75 Ω composite video signal 0.5 V[p-p] /75 Ω data signal and 2.5 V[p-p] /75 Ω vertical timing pulse multiplexed. 1.0 V[p-p] /75 Ω composite video signal 1.
Panasonic Security and Digital Imaging Company A Division of Matsushita Electric Corporation of America Executive Office: One Panasonic Way 3E-7, Secaucus, New Jersey 07094 Regional Offices: Northeast: One Panasonic Way, Secaucus, NJ 07094 (201) 348-7303 Southern: 1225 Northbrook Parkway, Suite 1-160, Suwanee, GA 30024 (770) 338-6838 Midwest: 1707 North Randall Road, Elgin, IL 60123 (847) 468-5211 Western: 6550 Katella Ave., Cypress, CA 90630 (714) 373-7840 Panasonic Canada Inc.