Datasheet
HL
3
ds_61C03_en_hl: 150113J
RATING
1. Coil data
1) AC coils
Notes: 1. The relay operates in a range of 80% to 110% V of the voltage rating, but ideally, in consideration of temporary voltage fluctuations, it should be operated at the
rated voltage.
In particular, for AC operation, if the applied voltage drops to 80% V or more below the rated voltage, humming will occur and a large current will flow leading possibly
to coil burnout.
2. The maximum allowable voltage is the maximum voltage fluctuation value for the coil power supply. This value is not a permissible value for continuous operation.
(This value differs depending on the ambient temperature. Please contact us for details.
2) DC coils (at 20C 68F)
Notes: 1. The rated excitation current is 10% (20C 68F).
2. The coil resistance for DC operation is the value measured when the coil temperature is 20C 68F. Compensate 0.4% for every 1C change in temperature.
3. The relay operates in a range of 80% to 110% V of the voltage rating, but ideally, in consideration of temporary voltage fluctuations, it should be operated at the
rated voltage.
4. For use with 200 V DC, connect a 10 K (5W) resistor, in series, to the 100 V DC relay.
5. The maximum allowable voltage is the maximum voltage fluctuation value for the coil power supply. This value is not a permissible value for continuous operation.
(This value differs depending on the ambient temperature. Please contact us for details.)
2. Specifications
Nominal coil
voltage
Nominal coil current
(mA)
Nominal operating power
(VA)
Pick-up voltage
(at 20C 68F)
Drop-out voltage
(at 20C 68F)
Inductance (H)
Max. allowable
voltage
50Hz 60Hz 50Hz 60Hz When drop-out When operating
6V AC 224 200 1.3 1.2
80%V or less of
nominal voltage
(Initial)
30%V or more of
nominal voltage
(Initial)
0.078 0.074
110%V of
nominal voltage
12V AC 111 100 1.3 1.2 0.312 0.295
24V AC 56 50 1.3 1.2 1.243 1.181
48V AC 28 25 1.3 1.2 4.974 4.145
100/110V AC 13.4/14.7 12/13.2 1.3 1.2 23.75 20.63
110/120V AC 12.2/13.5 10.9/11.9 1.3 1.2 27.19 25.57
200/220V AC 6.7/7.4 6/6.6 1.3 1.2 85.98 81.76
Nominal coil
voltage
Nominal coil current
(mA)
Nominal operating
power (W)
Coil resistance
()
Pick-up voltage
(at 20C 68F)
Drop-out voltage
(at 20C 68F)
Max. allowable voltage
(at 70C 158F)
6V DC 150 0.9 40
80%V or less of
nominal voltage
(Initial)
10%V or more of
nominal voltage
(Initial)
110%V of
nominal voltage
12V DC 75 0.9 160
24V DC 37 0.9 650
48V DC 18.5 0.9 2,600
100/110V DC 10 1.0 10,000
Characteristics Item Specifications
Contact
Initial contact resistance, max Max. 50 m (By voltage drop 6 V DC 1A)
Contact material AgSnO
2 type
Rating
Nominal switching capacity
1 Form C: 15A 125V AC, 10A 250V AC (resistive load)
2 Form C: 10A 125V AC (resistive load)
Min. switching capacity (Reference value)
*1
*1This value can change due to the switching frequency, environmental conditions and desired reliability level, therefore it is recommended to check this with the
actual load.
100mA 5V DC
Electrical
characteristics
Insulation resistance (Initial)
Min. 100M (at 500V DC)
Measurement at same location as “Initial breakdown voltage” section.
Breakdown voltage
(Initial)
Between open contacts 1,000 Vrms for 1min. (Detection current: 10mA.)
Between contact sets 1,500 Vrms for 1min. (Detection current: 10mA.)
Between contact and coil 2,000 Vrms for 1min. (Detection current: 10mA.)
Temperature rise Max. 80C (By resistive method, nominal voltage)
Operate time (at 20C 68F)
*2
*2For the AC coil types, the operate/release time will differ depending on the phase.
DC type/AC type: Max. 25ms (Nominal voltage applied to the coil, excluding contact bounce time.)
Release time (at 20C 68F)
*2
DC type/AC type: Max. 25ms (Nominal voltage applied to the coil, excluding contact bounce time.)
(without diode)
Mechanical
characteristics
Shock resistance
Functional Min. 196 m/s
2
(Half-wave pulse of sine wave: 11 ms; detection time: 10s.)
Destructive Min. 980 m/s
2
(Half-wave pulse of sine wave: 6 ms.)
Vibration resistance
Functional 10 to 55 Hz at double amplitude of 1 mm (Detection time: 10s.)
Destructive 10 to 55 Hz at double amplitude of 2 mm
Expected life
Mechanical AC type: 510
7
(at 180 cpm), DC type: 10
8
(at 180 cpm)
Electrical
AC load
1 Form C: 15A 125V AC, 10A 250V AC resistive load (cos=1) Life switching cycle: Min. 510
5
2 Form C: 10A 250V AC resistive load (cos=1) Life switching cycle: Min. 310
5
DC load
1 Form C: 3A 30V DC resistive load (cos=1) Life switching cycle: Min. 510
5
2 Form C: 3A 30V DC resistive load (cos=1) Life switching cycle: Min. 510
5
Conditions
Conditions for operation, transport and storage
*3
*3The upper operation ambient temperature limit is the maximum temperature that can satisfy the coil temperature rise value. Refer to “6. Usage, Storage and Transport
Conditions“ in AMBIENT ENVIRONMENT section in Relay Technical Information.
Ambient temperature: –50C to +70C –58F to +158F (Without LED indication);
–50C to +60C –58F to +140F (With LED indication)
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Max. Operating speed 20 cpm (at max. rating)
Unit weight Approx. 35g 1.23 oz
Notes:
If integrating into electrical appliances that will be subject to compliance to the Electrical Appliance and Material Safety Law, please use in an ambient temperature
between –50C to +40C –58F to +104F (AC type).