Datasheet
HG-C
10
Part description
PRO mode setting
Item
Default setting
Description
Response speed
setting
Set the response time.
“ ”:High precision 10ms, “ ”: Standard 5ms,
“ ”: High speed 1.5ms
Output operation
setting
Select the control output operation mode.
“
”: Light-ON, “ ”: Dark-ON
Sensing output
setting
Set the sensing output.
“ ”: Normal sensing mode
“ ”: 1-point teaching (Window comparator mode)
“ ”: 2-point teaching (Window comparator mode)
“ ”: 3-point teaching (Window comparator mode)
“ ”: Rising differential mode
“ ”: Trailing differential mode
Hysteresis
setting
〈
HG-C1030
〉
〈
HG-C1050
〉
〈
HG-C1100
〉
〈
HG-C1200
〉
〈
HG-C1400
〉
Set the hysteresis width.
HG-C1030: 0.001 to 5.00 mm 0.00004 to 0.197 in
HG-C1050: 0.01 to 15.00 mm 0.00039 to 0.591 in
HG-C1100: 0.02 to 35.00 mm 0.00079 to 1.378 in
HG-C1200: 0.1 to 80.0 mm 0.00394 to 3.150 in
HG-C1400: 0.2 to 200.0 mm 0.00787 to 7.874 in
External input
setting
Set the external input.
“ ”: Zero set function,“ ”: Teaching function
“ ”: Light emitting stop function, “ ”: Trigger
function
Timer setting
Set the timer operation. The timer time is fixed at 5ms.
“ ”: No timer, “ ”: OFF-delay timer
“ ”: ON-delay timer, “ ”: One-shot timer
Display setting
The display of the measured value can be changed.
“ ”: Normal, “ ”: Invert,“ ”: Offset
Hold setting
Set the control output and the analogue output operation
when a measurement error occurs (insufficient light
intensity, saturation of light intensity, out
of measurement range).
“ ”: Hold OFF, “ ”: Hold ON
ECO Setting
The digital display can be set to go OFF when key operation
is not performed for 30 seconds. Current consumption can
be reduced.
“ ”: ECO OFF, “ ”: ECO ON
Reset setting
Return to the default setting (factory setting).
“ ”: Reset NG, “ ”: Reset OK
UP key
TEACH key
Laser emission indicator (Green)
Output operation indicator (Orange)
Teaching indicator (Yellow)
Zero set indicator (Yellow)
DOWN key
PRO indicator (Yellow)
Digital indicator (Red)
Part description
PRO indicator
(Yellow)
DOWN key
(Select)
UP key (Select)
TEACH key (Confirmed)
PRECAUTIONS FOR PROPER USE
•
This catalog is only provided to help choose a product and the user’s guide
attached to the product must be read before use.
•
Never use this product as a sensing device for personnel
protection.
•
In case of using sensing devices for personnel protection, use
products which meet laws and standards, such as OSHA, ANSI
or IEC etc., for personnel protection applicable in each region or
country.
•
This product is classied as a Class 2 Laser Product
under JIS / IEC / GB standards and FDA * regulations. Do
not look at the laser beam directly or through an optical
system such as a lens.
•
The warning label (English) is attached to the product.
Handle the product according to the instruction given on
the warning label.
(The warning labels in Japanese and Chinese are packed
with the sensor.)
•
Do not operate products using methods other than the ones
described in the instruction manual included with each product.
Control or adjustment through procedures other than the ones
specied may cause hazardous laser radiation exposure.
* The product complies with the FDA regulations and satisfies requirements of the
FDA’s Laser Notice No. 50.