Datasheet
HG-C
8
Type Appearance
Measurement center
distance and
measurement range
Repeatability
Beam diameter
(Note)
Model No.
NPN output PNP output
Measurement center
30mm type
30 ± 5 mm
1.181 ± 0.197 in
10 μm
0.394 mil
Approx. ø50 μm
1.969 mil
HG-C1030 HG-C1030-P
Measurement center
50mm type
50 ± 15 mm
1.969 ± 0.591 in
30 μm
1.181 mil
Approx. ø70 μm
2.756 mil
HG-C1050 HG-C1050-P
Measurement center
100mm type
100 ± 35 mm
3.937 ± 1.328 in
70 μm
2.756 mil
Approx. ø120 μm
4.724 mil
HG-C1100 HG-C1100-P
Measurement center
200mm type
200 ± 80 mm
7.874 ± 3.150 in
200 μm
7.874 mil
Approx. ø300 μm
11.811 mil
HG-C1200 HG-C1200-P
Measurement center
400mm type
400 ± 200 mm
15.748 ± 7.874 in
300 μm 11.811 mil
(Measuring distance 200 to 400 mm 7.874 to 15.748 in)
800 μm 31.496 mil
(Measuring distance 400 to 600 mm 15.748 to 23.622 in)
Approx. ø500 μm
19.685 mil
HG-C1400 HG-C1400-P
Note: This is the size in the measurement center distance. These values were defined by using 1/e
2
(approx. 13.5%) of the center light intensity.
Due to leak light outside the specified area, the reflectance around the detecting point may be higher than at the point and this may affect the measurement value.
Type
Measurement center
30mm type
Measurement center
50mm type
Measurement center
100mm type
Measurement center
200mm type
Measurement center
400mm type
Item
Model No.
NPN output HG-C1030 HG-C1050 HG-C1100 HG-C1200 HG-C1400
PNP output HG-C1030-P HG-C1050-P HG-C1100-P HG-C1200-P HG-C1400-P
Applicable standard EMC Directive Compliance, FDA Standard
Measurement center distance
30 mm 1.181 in 50 mm 1.969 in 100 mm 3.937 in 200 mm 7.874 in 400 mm 15.748 in
Measurement range ±5 mm 0.197 in ±15 mm 0.591 in ±35 mm 1.328 in ±80 mm 3.150 in ±200 mm 7.874 in
Repeatability 10 μm 0.394 mil 30 μm 1.181 mil 70 μm 2.756 mil 200 μm 7.874 mil
300 μm 11.811 mil
(Measuring distance 200 to 400 mm 7.874 to 15.748 in)
800 μm 31.496 mi
(Measuring distance 400 to 600 mm 15.748 to 23.622 in)
Linearity ±0.1 % F.S. ±0.2 % F.S.
±0.2 % F.S.
(Measuring distance 200 to 400 mm 7.874 to 15.748 in)
±0.3 % F.S.
(Measuring distance 400 to 600 mm 15.748 to 23.622 in)
Temperature characteristic 0.03 % F.S./°C
Light source Red semiconductor laser Class 2 [JIS/IEC/GB/FDA (Note 2)] Max. output: 1 mW, emission peak wavelength: 655 nm 0.026 mil
Beam diameter (Note 3)
Approx. ø50 μm
1.969 mil
Approx. ø70 μm
2.756 mil
Approx. ø120 μm
4.724 mil
Approx. ø300 μm
11.811 mil
Approx. ø500 μm 19.685 mil
Supply voltage 12 to 24 V DC ±10 %, Ripple P-P 10 % or less
Power consumption 40 mA or less (at 24 V DC supply voltage), 60 mA or less (at 12 V DC supply voltage)
Control output
<NPN output type>
NPN open-collector transistor
•
Maximum sink current: 50 mA
•
Applied voltage: 30 V DC or less (Between control output to 0V)
•
Residual voltage: 1.5 V or less (At 50 mA sink current)
•
Leakage current: 0.1 mA or less
<PNP output type>
PNP open-collector transistor
•
Maximum source current: 50 mA
•
Applied voltage: 30 V DC or less (Between control output to +V)
•
Residual voltage: 1.5 V or less (At 50 mA source current)
•
Leakage current: 0.1 mA or less
Output operation Either Light-ON or Dark-ON
Short-circuit protection Incorporated (Auto reset type)
Analogue output • Output range: 0 to 5 V (at alarm: +5.2 V) • Output impedance: 100 Ω
Response time Switchable between 1.5 ms / 5 ms / 10 ms
External input
<NPN output type>
NPN non-contact input
•
Input conditions
Invalid: +8 to +V DC or Open
Valid: 0 to +1.2 V DC
•
Input impedance: Approx. 10 kΩ
<PNP output type>
PNP non-contact input
•
Input conditions
Invalid: 0 to +0.6 V DC or Open
Valid: +4 to +V DC
•
Input impedance: Approx. 10 kΩ
Degree of pollution 2
Operating altitude 2,000 m 6561.680 ft or less
Environmental
resistance
Protection IP67
(
IEC
)
Ambient temperature -10 to +45 °C -14 to 113 °F (No dew condensation or icing allowed), Storage: -20 to +60 °C -4 to 140 °F
Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH
Ambient illuminance Incandescent lamp: Acceptance surface illuminance 3,000 ℓx or less
Vibration resistance 10 to 55 Hz (period: 1 min.) frequency, 1.5 mm 0.059 in amplitude in X, Y and Z directions for two hours each
Shock resistance 500 m/s
2
acceleration (50 G approx.) in X, Y and Z directions for three times each
Cable 5-core composite cable, 2 m 6.5617 ft long
Cable extension Extension up to total 10 m 393.701 ft is possible with 0.3 mm
2
, or more, cable.
Material Enclosure: Aluminum die-cast, Front cover: Acrylic
Weight Net weight: approx. 35 g (without cable), approx. 85 g (including cable)
Notes: 1) Supply voltage: 24 V DC, ambient temperature: +20 °C +68 °F, response time: 10 ms, and analog output value of measurement center distance are used for
unspecied measurement conditions. The subject is white ceramics.
2) This is based on the FDA Standard, according to Laser Notice No. 50 of the FDA Standard.
3) This is the size in the measurement center distance. These values were dened by using 1/e
2
(approx. 13.5%) of the center light intensity. Due to leak light outside
the specied area, the reectance around the detecting point may be higher than at the point and this may affect the measurement value.
ORDER GUIDE
SPECIFICATIONS