Datasheet
HG-C
13
Error indication
•
In case of errors, attempt the following measures.
Error indication Description Remedy
<Hold OFF>
<Hold ON>
Measured value blinks
Insufcient amount of reected light.
The sensing object is out of the sensing range.
Conrm that the sensing distance is within the
specication range.
Adjust the installation angle of the sensor.
Flash memory is damaged or is past its life expectancy. Please contact our ofce.
Load of the sensing output is short-circuited causing an
over-current to ow.
Turn OFF the power and check the load.
The semiconductor laser is damaged or is past its life
expectancy.
Please contact our ofce.
•
When zero set is set, the measurement is not
performed normally.
•
Since the display setting is set to “Offset”, the zero set
function can not be used.
•
Conrm that the sensing distance is within the
specication range.
•
Set the display to any setting except “Offset.”
During teaching, the measurement is not performed
normally.
Conrm that the sensing distance is within the
specication range.
System error Please contact our ofce.
PRECAUTIONS FOR PROPER USE
DIMENSIONS (Unit: mm in)
CAD data can be downloaded from our website.
HG-C□
Sensor
DOWN key
UP key
TEACH key
Laser emission indicator (green)
Output operation indicator (orange)
Teaching indicator (yellow)
Zero set indicator (yellow)
PRO indicator (yellow)
Beam-emitting axis
Beam-receiving axis
2-ø3.2
3.5
0.138
ø4.1 mm 0.161 in, 2 m 6.562 ft long cable (5-core composite cable)
3.5 0.138
20
0.787
6.3
0.248
Measurement center
distance (L)
25
0.984
θ
18
0.709
37
1.457
44
1.732
Model No.
Measurement center distance (L)
HG-C1030(-P)
30 1.181 30°
HG-C1050(-P)
50 1.969 22.5°
HG-C1100(-P)
100 3.937 12.5°
HG-C1200(-P)
200 7.874 6.3°
HG-C1400(-P)
400 15.748 3.2°