Datasheet

Equipped with 0-5V analog output
+ V
0 V
External inputs
Control outputs
Analog voltage
output of 0-5V
Analog ground
(shielded)
The sensor not only indicates measured
values in mm, but also outputs analog voltage.
The data can be used for various calculations
and storage (logging) when the output is sent
to a PLC + analog unit.
Configurable external input
+
V
0V
External
input
Control
output
Analog voltage output (0-5V)
Analog ground (shielded)
Select one function.
Teaching
Zero adjustment
Trigger function
Laser ON/OFF
The external input can be congured
to perform one of four functions: zero
adjustment, teaching, Laser ON/OFF, trigger
function selection.
Teaching & window comparator mode
OFF
ON
OFF
TEACH
①
Object present
Threshold
Threshold
Set to Light-ON
Distance
Reference
point
1-point teaching
TEACH
①
TEACH
②
OFF
OFF
ON
2-point teaching
Threshold
Threshold
Set to Light-ON
Distance
Lower
limit
Upper
limit
TEACH
①
TEACH
②
TEACH
③
OFF
OFF
ON
3-point teaching
Object
A
Object
B
Ref. point 1
Ref. point 2
Ref. point 3
Set to Light-ON
Object
C
Distance
Threshold
Threshold
Perform 1-point teaching and the threshold
range is set for the distance from the
reference surface of the object to be detected.
Press the button TEACH once for the lower
(rst point) and once for the upper limit
(second point). This is useful for detecting
objects at different distances.
This is the method to set the threshold range by
conducting the teaching at 3 points (detecting
object A, B and C). After teaching, the reference
points are automatically sorted in ascending or-
der (reference point 1, 2 and 3). The thresholds
are set at the midpoints between reference point
1 and 2, and 2 and 3, respectively. This is useful
for detecting objects at different distances.
Measurement center distance: 50mm
Measuring range: ±15mm
Beam diameter: approx. 70μm
Repeatability: 30μm
Measurement center distance: 30mm
Measuring range: ±5mm
Beam diameter: approx. 50μm
Repeatability: 10μm
Measurement center distance: 100mm
Measuring range: ±35mm
Beam diameter: approx. 120μm
Repeatability: 70μm
Measurement center distance: 200mm
Measuring range: ±80mm
Beam diameter: approx. 300μm
Repeatability: 200μm
Measurement center distance: 400mm
Measuring range: ±200mm
Beam diameter: approx. 500μm
Repeatability (200-400mm): 300μm
Repeatability (400-600mm): 800μm
600mm