Datasheet
773
Rectangular-shaped Inductive Proximity Sensor GX-F/H SERIES
Selection
Guide
Amplier
Built-in
Amplier-
separated
GX-F/H
GXL
GL
GX-U/GX-FU/
GX-N
GX
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
CONTROL
DEVICES
ENDOSCOPE
LASER
MARKERS
PLC /
TERMINALS
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Sensing range
• The sensing range is specied for the standard sensing
object. With a non-ferrous metal, the sensing range is
obtained by multiplying with the correction coefcient
specied below. Further, the sensing range also changes
if the sensing object is smaller than the standard sensing
object or if the sensing object is plated.
Correction coefcient
Model
No.
Metal
GX-F6
GX-H6
type
GX-F8
GX-H8
type
GX-F12
GX-H12
type
GX-F15
GX-H15
type
GX-FL15
type
GX-HL15
type
Iron 1 1 1 1 1 1
Stainless steel
(SUS304)
0.76 approx. 0.76 approx. 0.79 approx. 0.68 approx. 0.70 approx. 0.76 approx.
Brass
0.50 approx. 0.50 approx. 0.56 approx. 0.47 approx. 0.45 approx. 0.50 approx.
Aluminum
0.48 approx. 0.48 approx. 0.53 approx. 0.45 approx. 0.43 approx. 0.48 approx.
Wiring
Others
• The output does not incorporate a short-circuit protection
circuit. Do not connect it directly to a power supply or a
capacitive load.
• Do not use during the initial transient time (50 ms) after
the power supply is switched on.
Inuence of surrounding metal
• When there is a metal near the sensor, keep the minimum
separation distance specied below.
GX-F6 type GX-F8 type
GX-F12 type GX-F15 type
GX-FL15 type
A
6 mm 0.236 in
(Note 1)
7.4 mm 0.291 in 7.1 mm 0.280 in 8 mm 0.315 in
8 mm 0.315 in
(Note 2)
B
8 mm 0.315 in 8 mm 0.315 in 20 mm 0.787 in 20 mm 0.787 in 30 mm 1.181 in
C
3 mm 0.118 in 3 mm 0.118 in 7 mm 0.276 in 7 mm 0.276 in 10 mm 0.394 in
GX-H6 type GX-H8 type
GX-H12 type GX-H15 type
GX-HL15 type
D
3 mm 0.118 in 4 mm 0.157 in 7 mm 0.276 in 6 mm 0.236 in 12 mm 0.472 in
E
10 mm 0.394 in 10 mm 0.394 in 20 mm 0.787 in 20 mm 0.787 in 30 mm 1.181 in
F
2 mm 0.079 in 3 mm 0.118 in 3 mm 0.118 in 0 mm 0 in
10 mm 0.394 in
(Note)
G
2 mm 0.079 in 3 mm 0.118 in 3 mm 0.118 in 3 mm 0.118 in 10 mm 0.394 in
Front sensing type
Metal
A
B
C
Metal Metal
C
Top sensing type
Metal
Metal
E
F
D
Metal
G
G
Metal
Mutual interference prevention
• When two or more sensors are installed in parallel or face
to face, keep the minimum separation distance specied
below to avoid mutual interference.
Front sensing
Top sensing
H J
GX-F6
GX-H6
type
Between “I” type
and non “I” type
0 mm
(Note 2)
15 mm
0.591 in
Between two “I” types
or two non “I” types
13 mm
0.512 in
25 mm
0.984 in
GX-F8
GX-H8
type
Between “I” type
and non “I” type
0 mm
(Note 2)
15 mm
0.591 in
Between two “I” types
or two non “I” types
20 mm
0.787 in
35 mm
1.378 in
GX-F12
GX-H12
type
Between “I” type
and non “I” type
0 mm
(Note 2)
25 mm
0.984 in
Between two “I” types
or two non “I” types
25 mm
0.984 in
50 mm
1.969 in
GX-F15
GX-H15
type
Between “I” type
and non “I” type
0 mm
(Note 2)
25 mm
0.984 in
Between two “I” types
or two non “I” types
45 mm
1.772 in
70 mm
2.756 in
GX-FL15
GX-HL15
type
Between “I” type
and non “I” type
0 mm
(Note 2)
25 mm
0.984 in
Between two “I” types
or two non “I” types
110 mm
3.059 in
170 mm
6.693 in
H
H
J
H
J
Notes: 1) “I” in the model No. species
the different frequency type.
2) Close mounting is possible for up to two sensors.
When mounting three sensors or more at an equal spacing, align
the model with “I” and the model without “I” alternately. The minimum
value of dimension “H” should be as given below.
GX-F6 / H6 type: 3.5mm 0.138 in
GX-F8 / H8 type: 6mm 0.236 in
GX-F12 / H12 type: 6.5mm 0.256 in
GX-F15 / H15 type: 15mm 0.591 in
GX-FL15 / HL15 type: 47.5mm 1.870 in
PRECAUTIONS FOR PROPER USE
Refer to General precautions.
Notes: 1) When using MS-GX6-1 (recommended mounting bracket), the
distance “A” including the thickness of mounting bracket will be
6.4 mm 0.252 in.
2) The GXL-FL15 type should be mounted on an insulator. To mount
it on an iron or stainless steel, use the enclosed aluminum sheet.
Note: When GX-HL15 type is mounted on an insulator or seated on the