Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.
Safety Precautions Observe the following notices to ensure personal safety or to prevent accidents. To ensure that you use this product correctly, read this User’s Manual thoroughly before use. Make sure that you fully understand the product and information on safety. This manual uses two safety flags to indicate different levels of danger.
Table of Contents Before You Start Manual to be Used Available Functions and GT Versions Chapter 1 Features and Functions ............................................................ 1-1 1.1 Features and Functions of GT Series ............................................................................ 1-2 1.2 Types of Units .................................................................................................................. 1-7 1.2.1 GT Series .................................................
3.1.9 GT02/GT02L/GT12 Installation Method ...................................................................... 3-8 3.1.10 Installing in Vertical Orientation ................................................................................ 3-9 3.1.11 Precaution When reinstalling GT .............................................................................. 3-9 3.2 Wiring the Power Supply .............................................................................................. 3-10 3.2.
4.4.1 Difference of Terminal blocks Between GT Models.................................................. 4-18 4.4.2 RS485 Connection with FP0R COM Port ................................................................. 4-19 4.4.3 RS485 Connection with FP-X COM Port .................................................................. 4-20 4.4.4 RS485 Connection with FPΣ COM Port.................................................................... 4-23 4.4.5 RS485 Connection with FP-e COM Port ....................
.4.2 Performance Specifications (GT05) .......................................................................... 6-15 6.4.3 Function Specifications (GT05) ................................................................................. 6-16 6.4.4 Interface Specifications (GT05) ................................................................................ 6-17 6.5 GT11 ................................................................................................................................
.2.4 AIGT8175 .................................................................................................................. 7-12 7.2.5 AIP81842 .................................................................................................................. 7-12 7.3 Table of Screen Messages............................................................................................ 7-13 7.4 BIN/HEX/BCD Code Correspondence Table ............................................................... 7-14 7.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.
Before You Start Usage conditions Operating environment (Use the unit within the range of the general specifications when installing) - Ambient temperatures: 0 to +50 C (It varies according to models when installing the unit in a horizontal orientation or using a C-NET adapter and FP programmer II.) - Ambient humidity: 20 to 85% RH (at 25 C, non-condensing) - Altitude of 2000 m or less - For use in pollution Degree 2 environment - Do not use it in the following environments.
Power supply - Twist the wires of the power supply. - The unit has sufficient noise immunity against the noise generated on the power line. However, it is recommended to take measures for reducing noise such as using an isolating transformer before supplying the power. And it is recommended to take measures such as installing a ferrite core. - Allocate an independent wiring for each power supplying line, PLC etc and operating device.
Manuals to be Used - The manuals to be used for GT series are common to all the models. GT series User's Manual ARCT1F511E - It is this manual. This manual describes the characteristics, specifications, installation and connections of each GT models. GT series Reference Manual ACGM0357V**EN - This manual describes the screen creation of GT series and the settings of various functions.
Available Functions and GT Versions We recommend to keep GT-series products up to date for use as usable functions will increase according to the upgrade. The latest version of GT can be installed by the tool. The upgrade of GTWIN is also necessary according to the upgrade of GT.
Version of GT02 and available functions Function Parts library Switch Lamp Message Data Bar graph Clock Line graph Alarm History List Keyboard Custom Other functions Recipe Recipe SD recipe Flow display Write device Sound Password Operation security Multi language exchange Logging function FP monitor function Display panel sideways setting Cable between GTs Copy SD memory card GT link PLC multiple connection Note1) Only referring to PLC can be set. Password GT02M2 GT02G2 1.00 or later 1.
Version of GT02L and available functions Function Parts Switch library Lamp Message Data Bar graph Clock Line graph History Alarm List Keyboard Custom Other Recipe Recipe functions SD recipe Flow display Write device Sound Password Password Operation security Multi language exchange Logging function FP monitor function Display panel sideways setting Cable between GTs Copy SD memory card GT link PLC multiple connection Note1) Only referring to PLC can be set. GT02L 1.00 or later 1.00 or later 1.
Version of GT05 and available functions Function Parts Switch library Lamp Message Data Bar graph Clock Line graph History Alarm List Keyboard Custom Other Recipe Recipe functions SD recipe Flow display Write device Sound Password Password Operation security Multi language exchange Logging function FP monitor function Display panel sideways setting Cable between GTs Copy SD memory card GT link PLC Multiple Connection GT05 1.00 or later 1.00 or later 1.00 or later 1.00 or later 1.00 or later 1.
Version of GT11 and available functions Function Parts Switch library Lamp Message Data Bar graph Clock Line graph History Alarm List Keyboard Custom Other Recipe Recipe functions SD recipe Flow display Write device Sound Password Password Operation security Multi language exchange Logging function Display panel sideways setting Cable between GTs Copy SD memory card GT link PLC multiple connection Note1) Summer time cannot be set. GT11 1.00 or later 1.00 or later 1.00 or later 1.00 or later 1.
Version of GT12 and available functions Function Parts library Switch Lamp Message Data Bar graph Clock Line graph Alarm History List Keyboard Custom Other functions Recipe Recipe SD recipe Flow display Write device Sound Password Operation security Multi language exchange Logging function FP monitor function Display panel sideways setting Cable between GTs Copy SD memory card GT link PLC multiple connection Password GT12M1 GT12G1 1.00 or later 1.00 or later 1.00 or later 1.00 or later 1.
Version of GT21 and available functions Function Parts Switch library Lamp Message Data Bar graph Clock Line graph History Alarm List Keyboard Custom Other Recipe Recipe functions SD recipe Flow display Write device Sound Password Password Operation security Multi language exchange Logging function Display panel sideways setting Cable between GTs Copy SD memory card GT link PLC multiple connection Note1) Summer time cannot be set. GT21 1.00 or later 1.00 or later 1.00 or later 1.00 or later 1.
Version of GT32 and available functions Function Parts library Switch Lamp Message Data Bar graph Clock Line graph Alarm History List Keyboard Custom Other functions Recipe Recipe SD recipe Flow display Write device Sound Password Operation security Multi language exchange Logging function FP monitor function Display panel sideways setting Cable between GTs Copy SD memory card GT link PLC multiple connection Password GT32M GT32T0 1.00 or later 1.00 or later 1.00 or later 1.00 or later 1.
Version of GT32-E and available functions Function Parts Switch library Lamp Message Data Bar graph Clock Line graph History Alarm List Keyboard Custom Other Recipe Recipe functions SD recipe Flow display Write device Sound Password Password 1.00 or later Multi language exchange Logging function FP monitor function Display panel sideways setting Cable between GTs Copy 1.00 or later GT link PLC multiple connection GT32M-E 1.00 or later 1.00 or later 1.00 or later 1.00 or later 1.00 or later 1.00 or later 1.
Change history GTWIN GT-series version version Ver. 2.80 GT32 Ver. 1.00 (New release) Ver. 2.90 Ver. 2.94 Ver. 2.96 Ver. 2.97 Ver. 2.98 GT05 Ver. 1.00 (New release) GT05 Ver. 1.10 GT32 Ver. 1.20 GT01 Ver. 1.35 GT05 Ver. 1.20 GT11 Ver. 1.25 GT21 Ver. 1.15 GT32 Ver. 1.30 GT05 Ver. 1.30 GT12 Ver. 1.00 (New release) GT32 Ver. 1.40 GT01 Ver.1.35 GT11 Ver.1.25 GT21 Ver.1.15 GT05 Ver. 1.40 GT12 Ver. 1.10 GT32 Ver. 1.50 Additional functions - New model - Equipped a SD memory card slot.
Ver.2.B1 Ver.2.C0 Ver.2.C1 GT01 Ver.1.39 GT02 Ver.1.11 GT02L Ver.1.01 GT05 Ver.1.71 GT11 Ver.1.29 GT12 Ver.1.41 GT21 Ver.1.19 GT32 Ver.1.81 GT02 Ver.1.30 GT02L Ver.1.20 GT05 Ver.1.90 GT12 Ver.1.60 GT32 Ver.2.00 GT32-E Ver.1.00 GT02 Ver.1.40 GT02L Ver.1.30 GT05 Ver.2.00 GT12 Ver.1.70 GT32 Ver.2.10 GT32-E Ver.1.10 -Bug fixing - New model(GT32-E) - FP monitor function - Added the mode to ignore CS/RS when using general- purpose serial communication.
Chapter 1 Features and Functions Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.
1.1 Features and Functions of GT Series Can be installed in a small space. As the GT series is a small and thin-shaped body, it can be installed in a small space. Also, as the projecting part from a wall surface is 4 mm, it looks neat after installation. The GT01, GT02, GT02L, GT11, GT12 and GT21 can be installed in vertical orientation. Number of colors can be selected as usage.
Saving various data with a SD memory card (Model equipped with SD memory card slot) Various data can be saved and read out with a SD memory card. Power can be supplied to the 5 V DC type with only one communication cable. The power is supplied from the TOOL port of a PLC, therefore, the wiring man-hours can be significantly reduced. Applicable models: Panasonic FP series Mitsubishi Electric Corporation FX series Three methods are available to switch the screen.
Through function is convenient for debugging A convenient “through” function makes it possible to transfer data from the GT and carry out PLC debugging at the same time that communication is going on between the GT and the FP series PLC. This significantly boosts efficiency in the workplace. For TOOL port models For USB port/Ethernet port models New functions can be available by upgrading the GT. The GT can be easily upgraded by donwloading the latest firmware from our website or using the GT Ver_UP tool.
Security Function - Password protection function A password (max. 8 characters) is specified for trasferring the screen data to GT from GTWIN. This function prevents the outflow of screen data if anyone except the administrator tries to read out the screen data. - Operation security function (GT02, GT02L, GT05, GT12, GT32, GT32-E) This function is used to limit the contents of displays and operations by setting the security level of users for each part.
Logging function (Model equipped with SD memory card slot) It is a function to collect and log arbitrary device values into a PLC at a constant period or when conditions are met. Logged data is saved in a SD memory card inserted in this unit in CSV format. This function is useful for obtaining the history of data. FP monitor function (GT02, GT02L, GT05, GT12, GT32, GT32-E) This function is used to monitor or change the settings and data of FP-series PLC on the GT screen.
1.2 Types of Units 1.2.1 GT Series Item name Model Display Interface specifications Backlight 3-color LED (green, red, orange) Power supply 5 V DC 24 V DC GT01 STN monochrom e LCD (128x64 dots) GT01 COM port TOOL port (RS232C compliant) 5 V DC 1-color LED (white) 3-color LED (white, red, pink) GT01R COM port USB port (USB1.1 compliant) GT02M1 GT02M2 GT02G0 STN monochrom e LCD (240x96 dots) COM port USB port (USB1.
Item name GT02L Model GT02L GT05M GT05 GT05G GT05S GT11 GT11 Display STN monochro me LCD (160x64 dots) STN monochro me LCD (320x240 dots) 4096color STN color LCD (320x240 dots) STN monochro me LCD (240x96 dots) GT12M1 GT12G0 STN monochro me LCD (320x120 dots) GT21 256-color STN color LCD (320x240 dots) Backlight 1-color LED (white) Power supply 5 V DC 3-color LED (white, red, pink) COM port USB port (USB1.
Item name Model GT32M Display STN monochrome LCD (320x240 dots) GT32T0 GT32 GT32T1 GT32M-E GT32-E GT32T-E 4096color TFT color LCD (320x240 dots) TFT monochro me LCD (320x240 dots) 4096color TFT color LCD (320x240 dots) Interface specifi-cations Backlight Power supply COM port communication specification RS232C COM port USB port (USB1.1 compliant) with SD memory card slot RS422 (RS485) RS232C CFL COM port USB port (USB1.
Maintenance parts Item name Waterproof packing Contents For GT01 For GT02/GT02L Note) For GT05 For GT11 For GT12 For GT21 For GT32 For GT32-E For repair 10 in set Product No.
Commercial product Item name Backup battery Item name Contents Backup battery for GT11/GT21 Printe d logo on GT GT version (Ver.) Model No. 1 pc CR2032 Usable SD memory card GT02M2 GT02G2 1.00 or later GT05 GT12 GT32 GT32-E Card type 1.39 or older 1.09 or older 1.49 or older 1.00 or later SD memory card 1.00 or later 1.40 or later 1.10 or later 1.50 or later 1.00 or later 1.00 or later 1.39 or older 1.09 or older 1.49 or older 1.
1.3 Screen Creation Tool 1.3.1 Tools Required for Screen Creation 1. Tool software It can be used for all the models in the GT series. 2. Screen transfer cable (Cable for connecting a PC) For GT01, GT11 and GT21: A cable between a PC (D-sub 9-pin) and GT (TOOL port) is available. For GT02, GT02L, GT05, GT12, GT32 and GT32-E: Prepare a commercal USB cable or LAN cable (for GT32T1 only). 1.3.2 Software Usage Environment and Applicable Cables Screen creation tool software Terminal GTWIN Ver.
Screen transfer cable For connection between PC (USB) and Programmable Display (GT02/GT02L/GT05/GT12/GT32) USB cable (Commercial product) Applicable model Cable type Length GT05/GT32/ GT32-E USB2.0 (or 1.1) AB type GT02/GT02L/GT12 USB2.0 (or 1.1) cable Max. 5 m A type (Male): miniB type male Max. 5 m Note) Windows 2000 or later OS is required for the communication with a USB.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.
Chapter 2 Names and Functions of Parts Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.
2.1 Part Names 2.1.1 GT01, GT11 and GT21 GT01/GT01R GT11 GT21 Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.
Touch screen Various screens are displayed here. Switches can be operated and data entered simply by touching the touch screen. (A sheet is affixed to the touch panel to protect it from scratches when shipping. Please remove it before using the GT.) Optional protective sheets are available to protect the touch screen surface and keep it clean. Reference: <1.4.
2.1.2 GT02/GT02L GT02M2, GT02G2 GT02M0, GT02M1, GT02G0, GT02G1 GT02L Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.
Liquid crystal display panel/touch panel Various screens are displayed here. A touch panel is provided on the liquid crystal display panel, and switches can be operated and data entered simply by touching the panel. Optional protective sheets are also available to protect the touch panel and keep it clean. (A sheet is affixed to the touch panel to protect it from scratches when shipping. Please remove it before using the GT.) SD memory card slot A SD memory card is inserted in this slot.
2.1.3 GT05/GT12/GT32 GT05 GT12 GT32 Standard High function GT32-E Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.
Liquid crystal display panel/touch panel Various screens are displayed here. A touch panel is provided on the liquid crystal display panel, and switches can be operated and data entered simply by touching the panel. Optional protective sheets are also available to protect the touch panel and keep it clean. (A sheet is affixed to the touch panel to protect it from scratches when shipping. Please remove it before using the GT.
2.2 Terminal Layouts of COM Port 2.2.1 GT01 5 V/RS232C type Pin name + − NC SD RD NC NC SG Name +5 V 0V Not connected Send data Receive data Not connected Not connected Signal ground Signal direction GT→External device GT←External device - Product No. AIGT0030B1 AIGT0030H1 AIGT0130B1 AIGT0130H1 AIGT0230B1 AIGT0230H1 Note: There is no RS and CS (control lines).
2.2.2 GT02 5 V/RS232C type Pin name + − FG SD RD RS CS SG Name +5 V 0V Functional ground Send data Receive data Request to send Clear to send Signal ground Signal direction GT→External device GT←External device GT→External device GT←External device - Product No.
2.2.3 GT02L 5 V/RS232C type Pin name + − FG SD RD RS CS SG Name +5 V 0V Functional ground Send data Receive data Request to send Clear to send Signal ground Signal direction GT→External device GT←External device GT→External device GT←External device - Pin name + − FG +SD −SD +RD −RD E Name +5 V 0V Functional ground Send data Send data Receive data Receive data Terminal resistance Signal direction GT→External device(+) GT→External device(−) GT←External device(+) GT←External device(−) - Product No.
2.2.4 GT11/GT12 24 V/RS232C type Pin name + − FG SD RD RS CS SG Name +24 V 0V Functional ground Send data Receive data Request to send Clear to send Signal ground Signal direction GT→External device GT←External device GT→External device GT←External device - Product No.
2.2.5 GT21 24 V/RS232C type Pin name + − FG SD RD RS CS SG Name +24 V 0V Functional ground Send data Receive data Request to send Clear to send Signal ground Signal direction GT→External device GT←External device GT→External device GT←External device - Pin name + − FG +SD −SD +RD −RD E Name +24 V 0V Functional ground Send data Send data Receive data Receive data Terminal resistance Signal direction GT→External device(+) GT→External device(−) GT←External device(+) GT←External device(−) - Product No.
2.2.6 GT05/GT32/GT32-E 24 V/RS232C type Pin name + − FG SD RD RS CS SG Name +24 V 0V Functional ground Send data Receive data Request to send Clear to send Signal ground Signal direction GT→External device GT←External device GT→External device GT←External device - Product No.
2.3 Connecting to Screen Creation Tool GTWIN 2.3.1 TOOL Port Pin No. 1 2 3 4 5 Name Signal ground Send data Receive data Not connected +5 V Abbre. SG SD RD N.C. (+5V) Signal direction GT→External device GT←External device - Note: • The +5V of Pin 5 is reserved for the FP Programmer II. It should not be used for any other application. If using it, there is a restriction on the ambient temperature. The pin 5 of GT01 is N.C. 2.3.
2.3.3 Ethernet Port Ethernet connection GT32T1 has a Ethernet port. Communication with our software such as GTWIN becomes available by connecting to a PC with a LAN cable. Ethernet communication function • Screen transfer (Baud rate: fixed at 115200 bps. It takes at least 3 times longer than the transfer using USB.) • Through function using our PLCs * Specifying the destinations to connect enables the communication with multiple units using a HUB. Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.
Required items for connection • LAN cable Either straight cable or crossing cable can be used. (MDI/MDI-X Automatic crossover function) Settings for Ethernet connection Follow the procedure below to communicate with the Ethernet connection. 1. Connect the GT to a PC with a Ethernet cable. 2. Specify the settings such as IP address for the GT. 3. Startup the GTWIN and specify the communication condition. The factory settings are as follows. IP Address Subnetmask Default Gateway Port No 192.168.1.5 255.255.
• Setting of destination (PLC side) IP address: Specify the IP address of the GT to be connected in decimal. Port No.: Set it within the range of 1 to 32767 in decimal. (Default: 9094) Specify the same setting as the one of GT. • Communication time out: Set the time-out period after connection establishment for every communication within the range of 1 to 950 seconds.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.
Chapter 3 Installation and Wiring Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.
3.1 Installation 3.1.1 Installation Environment When installing and using the GT series, always make sure the following conditions are observed. Usage conditions Operating environment (Use the unit within the range of the general specifications when installing) - Ambient temperatures: 0 to +50 °C (It varies according to models when installing the unit in a horizontal orientation or using a C-NET adapter and FP programmer II.
Static electricity - Do not touch connector pins directly to prevent static electricity from causing damage. - Always rid yourself of any static electricity before handling this product. - If excessive estatic electricity is applied to the panel surface, the LCD panel may be damaged. Power supply - Twist the wires of the power supply. - The unit has sufficient noise immunity against the noise generated on the power line.
3.1.2 Restriction According to Mounting Directions If the unit is being installed in a horizontal orientation, or our Programmer II and C-NET adaptor are being connected to the TOOL port, note that the ambient usage temperature should be as below.
3.1.5 Mounting Screws Secure the GT to a mounting plate using the fitting and screws provided with the unit. Recommended screws Recommended product Mounting screw GT unit GT01/GT11 GT05/GT21/GT32/ GT32-E Size M3 – 20 M3 – 3.5 Others Material: SW pane-head (+) Galvanization, trivalent chromate Quantity 4 pcs/unit GT02/GT02L/GT12 dedicated screw The GT02/GT02L/GT12 dedicated screw is not sold on the open market.
3.1.6 GT01 and GT11 Installation Method Secure the GT to the installation panel using the four fittings and four screws provided with the unit. 1. Place the GT in the installation panel. 2. Insert the fittings into the grooves provided in the GT, and tighten the screws to secure the GT to the installation panel. The screw tightening torque should be 0.1 to 0.25 N· m, and tighten them uniformly.
3.1.8 GT05/GT32/GT32-E Installation Method Secure the GT32 to the installation panel using the two fittings and four screws provided with the unit. 1. Place the GT main unit in the installation panel. 2. Insert the fittings into the grooves provided in the GT main unit, and tighten the screws to secure the GT main unit to the installation panel. GT05 and GT32 The screw tightening torque should be 0.1 to 0.25 N· m, and tighten them uniformly. GT32-E The screw tightening torque should be 0.2 to 0.
3.1.9 GT02/GT02L/GT12 Installation Method Secure the GT12 or GT02 to the installation panel using the two fittings and four dedicated screws provided with the unit. 1. Place the GT main unit in the installation panel. 2. Insert the fittings into the grooves provided in the GT main unit, and tighten the screws to secure the GT main unit to the installation panel. Note: - The cross slot screwdriver No. 1 must be used. - Tightening torque: 0.2 to 0.
3.1.10 Installing in Vertical Orientation Normally, the GT series is installed horizontally long, however, some models can be installed vertically long. At that time, the right side becomes the upper side. GT01 GT02 GT02L GT11 GT12 GT21 Note: - The side that the COM port is situated becomes the upper side. If the GT is installed upside down, the screen will be upside down. - The allowable ambient temperature for GT11 is different.
3.2 Wiring the Power Supply 3.2.1 Wiring the Power supply The power supply should be wired by securely connecting the terminal on the rear of the main unit to the terminal. Use twisted wiring for the power supply In order to minimize influence from noise, the wiring for the power supply should be twisted.
3.2.2 Grounding Be sure to ground when the influence of noise is great The unit is tolerant against noise in normal environments, but if the environment is particularly susceptible to noise, please ground. Use dedicated grounding • For grounding purposes, use wires with a minimum of 2 mm2. The grounding connection should have a resistance of less than 100 Ω. • Make the grounding point as close as possible to the GT and keep the distance of the grounding wire short.
3.3 Wiring the COM Port Accessory communication connector/applicable wiring The communication connector used for the COM port (provided as an accessory with the main unit) has a screw-tightening type of terminal block. The wiring shown below should be used. Applicable wiring (twisted wiring) Size Conductor cross-section surface area AWG 28 to 16 0.08 to 1.25 mm2 Use a special tool to tighten the terminal block of the communication connector. Using a screwdriver made by Panasonic Electric Works Co., Ltd.
Wiring method (1) Remove the sheath from the wire. (2) Insert the wire all the way into the terminal block, and tighten the screw in the clockwise direction to secure it. Precautions concerning wiring The following precautions should be observed, to avoid broken or disconnected wires. • When removing the sheath, be careful not to scratch the core wire. • Wire the terminal without twisting the core wire. • The core wire should be connected without soldering it.
3.4 Precautions when Wiring COM Port Precautions are different depending on communication conditions. Arrange wirings according to the following instructions. 3.4.1 GT01 (5 V DC) RS232C type - Perform wiring and placement of the cable so that there is no impression of external noise on the cable and no induction. - Use shielded wires for distribution cables. (Recommended cable: AIGT8142 with one ferrite core) - It conforms to CE marking. As conditions, the following wiring is required. 1.
3.4.2 GT02/GT02L (5 V DC) RS232C type - Perform wiring and placement of the cable so that there is no impression of external noise on the cable and no induction. - Use shielded wires for distribution cables. (Recommended cable: AIGT8142) - It conforms to CE marking. As conditions, the following wiring is required. 1.Perform grounding of the cable shield. 2.Perform grounding of the GT. GT02 GT02L RS422 (RS485) type - There is no RS and CS (control lines).
3.4.3 RS232C Communication - There is no RS and CS (control lines) for GT01. - Perform wiring and placement of the cable so that there is no impression of external noise on the cable and no induction. - Use shielded wires for distribution cables. (Recommended cable: AIGT8162) - It conforms to CE marking. As conditions, the following wiring is required. 1. Install a ferrite core to the cable. (For GT11 only) (Recommended ferrite core: Seiwa Electric’s E04SR170730A or equivalent) 2.
3.4.4 RS422 (RS485) Communication - There is no RS and CS (control lines). - Perform wiring and placement of the cable so that there is no impression of external noise on the cable and no induction. - Use shielded wires for distribution cables. (Recommended cable: AIGT8175 (for Mitsubishi FX series) - When using shielded cable with crossover wiring for the RS485 transmission line, grounded one end. - “E” is used to set the terminal unit. - It conforms to CE marking.
3.5 Precautions when Wiring Ethernet Port (GT32T1) - Although more than one GT32T1 can be connected using a hub, communication is performed with one unit each. Specify each destination to communicate. - Use a UTP cable (unshielded cable) for the Ethernet cable, and take measures for noises such as installing a ferrite core if necessary. - It conforms to CE marking. As conditions, the following wiring is required. 1. Do not use a shield wire for the Ethernet cable. 2.
3.6 Options 3.6.1 Backup Battery Backup battery The internal data in the GT can be backed up using the backup battery. Use the following backup batteries. GT model GT11 GT21 GT02M2,GT02G2 GT05 GT12 GT32 GT32-E Battery type Product No. Button type lithium battery CR2032 (commercial item) Backup battery AFPX-BATT (The backup battery for the FP-X is used.) Battery life Battery life, when operating at a normal temperature (25C), a normal humidity (65% RH), and a voltage of 24 V DC, is as follows.
3.6.2 How to Install the Battery (Lithium Button Battery) (The figures below is explained using the GT11. Note: Do not touch the electronic parts when removing and installing the battery. 3.6.3 How to Install the Battery (Backup Battery) The figures below is explained using the GT32. 1. Remove the battery cover. 2. Connect the connector to make the red line be the (+) side, and place a battery in the circular frame. 3. Fit the battery cover. Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.
3.6.4 Dead Battery Mark If the battery voltage drops too low, the battery mark is displayed at the bottom right of the GT screen. When the battery voltage drops It can be specified in the GTWIN configuration settings, whether or not the dead battery mark is displayed . Note: If the battery voltage drops too low, the BAT LOW flag of the basic communication area map goes on. If the battery has run down completely, the BAT flag of the basic communication area map goes on.
Replacing the front panel protective sheet (For the type without protective film) 1. Remove the peel-off film attached to the front panel protective sheet. 2. Attach the front panel protective sheet. Attach the front sheet to fit the liquid crystal part of GT. At this time, try not to allow the air to get in the attached face. If the air was in, remove the air to be out with fingers. Do not press the front panel hard as it may cause the damage to the touch switch. 3.6.
Chapter 4 Connecting with PLC Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.
4.1 Connection with PLC How to connect with PLC ・Connecting between one GT and one PLC via 1:1 communication ・Connecting between one GT and multiple PLCs via 1:N communication (PLC multiple connection) ・Connecting between one PLC and multiple GTs via 1:N communication (GT link) ・Connecting using the general-purpose serial communication mode ・ As for the 5 V DC-type GT01, power can be supplied with a communication cable only. 4.1.
4.1.3 Connecting to the PLCs made by Other Companies For information on the connection with PLCs manufactured by other companies, see the latest GTWIN HELP or our website where you can get the manual. Reference: < Connection with Other Companies' PLCs Manual ARCT1F449E> 4.1.4 Connecting to a Serial Device Devices other than PLCs can be connected by using the general-purpose serial communication mode of the GT. Also, PLCs made by other companies which are not put on our website can be used.
4.2 RS232C Connection 4.2.1 Difference of Terminal blocks Between GT Models Although the terminal blocks vary according to the GT models, the connection method is the same. The connection diagram for 24 V DC is described with the terminal blocks other than the one for GT01. 24 V DC type other than GT01 24 V DC-type GT01 5 V DC-type GT01 5 V DC-type GT02/GT02L Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.
4.2.2 RS232C Connection with PLC Tool Port Connecting with 5 V DC type Usable models PLC FP-X FPΣ FP0/FP0R FP-e FP2/FP2SH PLC communication cable Mini-DIN 5-pin loose-wire cable AIGT8142 Programmable display 5 V DC type RS232C type Connecting to the TOOL port Note: Connecting to the COM port is not available. - Keep the cable no longer than 3 m. - In case of connecting to PLC with all expansion slots used, prepare an external 5 V DC power supply for the GT01 due to current consumption limits.
Connecting with 24 V DC type Usable models PLC FP-X FPΣ FP0/FP0R FP-e FP2/FP2SH PLC communication cable Mini-DIN 5-pin loose-wire cable AIGT8162 AIGT8165 AIGT8160 Programmable display 24 V DC RS232C type Connecting to the TOOL port Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.
4.2.3 RS232C Connection with FP-X COM Port Connecting to the COM port of FP-X Communication cassette Usable models FP-X PLC AFPX-COM1 AFPX-COM2 AFPX-COM3 AFPX-COM4 AFPX-COM5 PLC communication cable Loose-wire cable Programmable display 5 V DC 24 V DC RS232C type Connecting to the 1- channel type RS232C Connecting to the 2-channel type RS232C As for the connection to S2 and R2 for COM2, make the same connection as S1 and S2. Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.
Connecting to the 1-channel type RS485 and 1-channel type RS232C Connecting to the 1-channel type Ethernet and 1-channel type RS232C It cannot be connected with Ethernet. Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.
4.2.4 RS232C Connection with FPΣ COM Port Connecting to the COM port Usable models PLC FPΣ PLC communication cable Programmable display 5 V DC 24 V DC Loose-wire cable RS232C type Connecting to the 1-channel type RS232C Connecting to the 2-channel type RS232C As for the connection to S2 and R2 for COM2, make the same connection as S1 and S2. Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.
Connecting to the 1-channel type RS485 and 1-channel type RS232C The connections with either one unit or two units are available. Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.
4.2.5 RS232C Connection with FP0/FP0R COM Port Connecting to the COM port Usable models PLC FP0 FP0R PLC communication cable RS232C type Programmable display 5 V DC 24 V DC RS232C type Connecting to the COM port of FP0/FP0R Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.
4.2.6 RS232C Connection with FP-e COM Port Connecting to the COM port Usable models PLC FP-e PLC communication cable Loose-wire cable Programmable display 5 V DC 24 V DC RS232C type Connecting to the FP-e (RS232C) Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.
4.2.7 RS232C Connection with FP2/FP2SH COM Port Connecting to the COM port FP2/FP2SH CPU unit FP2 Computer Communication Unit FP2 Multi Communication Unit Usable models PLC FP2/FP2CH CPU unit FP2 Computer Communication Unit FP2 Multi Communication Communication block Unit FP2-CB232 PLC communication cable D-SUB 9-pin loose-wire cable AIP81842 Programmable display 5 V DC 24 V DC RS232C type Connecting to the TOOL port Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.
4.3 RS422 Connection 4.3.1 Difference of Terminal blocks Between GT Models Although the terminal blocks vary between the 5 V DC type and 24 V DC type, the connection method is the same. The connection diagram is described with the terminal block for 24 V DC. 24 V DC type 5 V DC-type GT01 5 V DC-type GT02/GT02L Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.
4.3.2 RS422 Connection with FP-X COM Port Usable models PLC FP-X AFPX-COM3 PLC communication cable Loose-wire cable Programmable display 5 V DC 24 V DC RS422/RS485 type Connecting to the FP-X Communicatoin cassette, 1-channel type RS485/RS422 Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.
4.3.3 RS422 Connection with FP2/FP2SH COM Port Connecting to the COM port Usable models PLC Communication FP2 Multi block Communication FP2-CB422 Unit PLC communication cable D-SUB 9-pin loose-wire cable AIP81842 Programmable display 5 V DC 24 V DC RS422/ RS485 type Connecting to the FP2 Multi Communication Unit (MCU) + Communication block (RS422) Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.
4.3.4 RS422 Connection with C-NET Adapter Usable models PLC FP series PLC communication cable C-NET adapter AFP8536 AFP8532 AFP15401 AFP15402 Programmable display 5 V DC 24 V DC RS422/RS485 type Conneciton method Communication settings on the PLC side Specify the setting to match with the setting for the GT using the tool software at the PLC side. C-NET adapter setting Set the termination (TERMINATE) to on. Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.
4.4 RS485 Connection 4.4.1 Difference of Terminal blocks Between GT Models Although the terminal blocks vary between the 5 V DC type and 24 V DC type, the connection method is the same. The connection diagram is described with the terminal block for 24 V DC. 24 V DC type 5 V DC-type GT01 5 V DC-type GT02/GT02L Note) RS485 communicatoin is performed using the RS422 terminal blocks. Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.
4.4.2 RS485 Connection with FP0R COM Port Connecting to the COM port Usable models PLC FP0R RS485 type PLC communication cable Loose-wire cable Programmable display 5 V DC 24 V DC RS422/RS485 type Connecting to the COM port of FP0R 4-19 Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.
4.4.3 RS485 Connection with FP-X COM Port Usable models FP-X PLC AFPX-COM3 AFPX-COM4 AFPX-COM6 PLC communication cable Loose-wire cable Programmable display 5 V DC 24 V DC RS422/RS485 type Connecting to the FP-X Communicatoin cassette, 1-channel type RS485/RS422 Note: Check the usable GT models for 1:N communication. Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.
Connecting to the 1-channel type RS485 and 1-channel type RS422 Note: Check the usable GT models for 1:N communication. Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.
Connecting to the 2-channel type RS485 Note: Check the usable GT models for 1:N communication. Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.
4.4.4 RS485 Connection with FPΣ COM Port Connecting to the COM port Usable models FPΣ PLC AFPG803 AFPG806 PLC communication cable Loose-wire cable Programmable display 5 V DC 24 V DC RS422/RS485 type Connecting to the 1-channel type RS485 Note: Check the usable GT models for 1:N communication. Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.
Connecting to the 1-channel type RS485 and 1-channel type RS232C Note: Check the usable GT models for 1:N communication. Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.
4.4.5 RS485 Connection with FP-e COM Port Connecting to the COM port Usable models PLC FP-e RS485 type PLC communication cable Loose-wire cable Programmable display 5 V DC 24 V DC RS422/RS485 type Connecting to the FP-e (RS485) Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.
4.4.6 RS485Connection with FP2/FP2SH Usable models PLC Communication FP2 Multi block Communication FP2-CB485 Unit PLC communication cable Loose-wire cable Programmable display 5 V DC 24 V DC RS422/ RS485 type Connecting to the FP2 Multi Communication Unit (MCU) + Communication block (RS485) Note: Check the usable GT models for 1:N communication. Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.
4.4.7 Precautions When Communicating With RS485 When communication with the RS485, the transmission line for sending and receiving data is the same. Time taken until the connected device sends a response after sending a command from the GT: If a response is sent too quickly, the GT may not be able to receive it. Adjust the time if necessary. For our FP series FPΣ or FP-X, the time can be specified using the SYS1 instruction.
4.5 Connection With a PLC 4.5.1 Automatic Communication Settings Function After turning on the power supply, if there is not response from the PLC connected to the GT, the GT switches to the automatic setting mode for the communication conditions. In the automatic setting mode, commands are sent to the PLC while changing the communication conditions in the sequence shown below. The GT, in automatic setting mode, continues to repeat steps to until there is a response from the PLC.
4.5.2 Through Function With the GT series, communication can be set to take place automatically between the COM port of a GT and TOOL port of a PLC in a “through function”. When the FP series tool software installed in the computer connected to the GT series as shown below is booted, PLC programs can be edited through the GT series. The through function does not require any special settings, and is always in the standby mode. For TOOL port type For USB port type Phone: 800.894.0412 - Fax: 888.723.
Note: • Precautions when using the through function The system should be set up so that the Timeout period in the FP series software (FPWIN) (A) is larger than the waiting time for communication retries of the GT COM port (B), meaningn (A) > (B). If the system is set up so that A = B or A < B, the through function will not work properly. When the baud rate of the GT TOOL port is 230400 bps, the through function cannot be used. Communicate at 115200 bps or lower for using the throught function.
4.5.3 How to Make Communication Settings Using the FPWIN GR Please read below to make PLC communication settings using the FPWIN GR. 1. Select “PLC system register setting” from the Option menu (O). 2. The window below will be displayed. Select “Tool port setting” when connecting to the tool port or “COM port setting” when connecting to the COM port. Please match the transfer format and transmission speed settings to those of the GT.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.
Chapter 5 Troubleshooting Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.
5.1 What to DO If Something Unusual Occurs (GT01/GT11/ GT21) Problem Screen is Cause Solution 1) Power is not on. 1) Supply the power supply to unit as per 2) (When only lamp and message parts are 2) Check the address of the substitute reference blank specifications. configured to the base screen) Value of device and the device values on the PLC side. substitute reference device value does not exist in substitute data.
Problem Screen Cause 1) No screen number has been written to doesn’t the screen setting area (the first word switch in the basic communication area word Solution 1) Specify correct screen number. device) from the PLC. 2) The screen number to which you are 2) Refer to Reference Manual. attempting to switch has already been written from the PLC to the screen setting area (the first word in the basic communication area word device.) Screen is 1) The power voltage may be low.
Problem Cause Solution Buzzer sounds Bit F of the first word in the basic Set the F bit to OFF on the PLC side. (Do not use the continuously communication area bit device is set basic communication area with ladder programs.) to ON. Backlight color Bits A and B, and Bit D, of the first Perform correct bit operations on the PLC side. (Do not changes/ word (backlight color setting) in the use the basic communication area with ladder flashes basic communication area bit device programs.
5.2 What to DO If Something Unusual Occurs (GT02/GT02L/GT05/GT12/GT32/GT32-E) Problem Screen is blank Error code [ER****] appears at the top right of the screen Screen displays [No Screen data] Screen displays [Screen No. Error] Cause 1) Power is not on. 2) (When only lamp and message parts are configured to the base screen) Value of substitute reference device value does not exist in substitute data. An error has occurred in communication between the GT and an external device (e.g. PLC).
Problem Screen is dim Cause 1) The power voltage may be low. 2) The contrast is set too low. 3) The backlight is off due to the [Backlight Auto-off] setting in the [Setup] of the GT configuration settings in GTWIN. Solution 1) Check the capacity of the power supply unit if it is enough for the GT’s power consumption. 2) Bring up the system menu and adjust the contrast. 3) Touching any area of the screen lights that area. If a switch part is set on the touched area, the area will not light even if touched.
Problem Buzzer sounds continuously Backlight color changes/ flashes Cannot transfer data from GTWIN Cause Bit F of the first word in the basic communication area bit device is set to ON. Bits A and B, and Bit D, of the first word (backlight color setting) in the basic communication area bit device are set to ON. Or, Bits C and D (backlight flashing setting) are set to ON. 1) The USB or LAN cable (GT32T1) is not connected. 2) The PC and GT COM. port are connected.
Operation security function Message “Incorrect password.” Is displayed on the login screen. “Incorrect password.” Is displayed on the password change screen. “Please verify your password again.” Is displayed on the password change screen. “Use another password.” Is displayed on the password change screen. “Password setting incomplete.” Is displayed on the password change screen. “Your password cannot be deleted.” Is displayed on the password management screen.
When using the SD memory card. Data may be erased or the SD memory card may be damaged during the operation. Take measures for the situations as below. Problem Measures Transmitting GT configuration setting file using the logging function clears the information on the SRAM. Save all the data remained in the log before transmission. Data in SRAM (Record area for When data cannot be saved in the SD memory card, the data beginning with the logging) is lost.
5.3 Error Codes and How to Handle Them 5.3.1 About Error Codes When an error occurs in the GT series, an error code displays at the top right of the screen. There are two types of error codes, GT series error codes and PLC error codes. 5.3.2 GT Series Error Codes The following error codes are displayed when there is an error in the GT. For GT01, GT11 and GT21 Code No. Content ERFF ER21 ER22 Time up error No response from the PLC. Data error A data error occurred during communication.
Code No. Content **1002 SD memory card memory full **1003 SD memory card reading error **1005 **1006 **1020 **1021 SD memory card saved file name error SD memory card recognition error PLC model unmatch error PLC model unsupported error **1022 Password protection error **1023 Master memory installation error **1025 General-purpose memory shortage **1027 Remote mode error **102D Forced operation error **1040 **1041 **1042 The record area for logging was overwritten.
Code No. **1060 **1080 **2000 **20FF Content Index register value error Start time device value error Connected GT designation area error The bit corresponding to the connected GT in the connected GT designation area. Token error There is a GT unresponsive to the token. **F000 User’s memory error Cause and solution The device value for index modifier is out of the setting range. Check the setting value. The value at the start of the line graph function is out of the setting range.
5.3.3 When Connected to a FP Series PLC Error codes which are sent from the PLC are listed in the table below. For details, refer to the table of MEWTOCOL-COM communication errors in PLC user’s manuals. For GT01, GT11 and GT21 Code No. Content Data error A data error ER21 occurred during communication. Overrun error The PLC isn’t ER22 receiving data. BCC error A data error ER40 occurred during communication. Format error The PLC has been sent a command ER41 that doesn’t match the protocol.
For GT02, GT02L, GT05, GT12, GT32 and GT32-E Code No. Content Cause and solution Data error 1) There is an error in the communication condition settings. Check A data error the PLC and GT baud rate and transfer format. ER0021 occurred during 2) There is a temporary error due to noise, etc. Re-supply power to communication. the PLC and GT. The CPU unit’s reception buffer is overflowing. Overrun error There could be an error in the PLC. ER0022 The PLC isn’t Re-supply power to the PLC and GT. receiving data.
5.3.4 When Connected to a PLC (FX Series) Made by Mitsubishi Electric Corporation For GT01, GT11 and GT21 Code No. Content ERFF ER10 ER12 ER61 Time up error There is no response from the PLC. Data error A data error occurred during communication Overrun error The GT cannot receive data. PLC error A NAK error has been returned from the PLC. Cause and solution 1) PLC connection cable is disconnected. Check the wiring of the connection cable and check for disconnection.
5.3.5 When Connected to a PLC Made by Omron Corporation For GT01, GT11 and GT21 Code No. Content ER00 Time up error There is no response from the PLC. Cause and solution 1) PLC connection cable is disconnected. Check the wiring of the connection cable and check for disconnection. 2) It is a temporary error caused by noise, etc. Turn on the power supplies for PLC or GT again. Cannot be executed due to operation mode.
5.3.6 When Connected to Modbus For GT01, GT11 and GT21 Code No. Content ERFF Time up error There is no response from the PLC. ERFE Response error There is an abnormal response returned from the external device. Cause and solution 1) PLC connection cable is disconnected. Check the wiring of the connection cable and check for disconnection. 2) It is a temporary error caused by noise, etc. Turn on the power supplies for PLC or GT again. Check the data to be returned from the external device.
5.3.8 When Performing General-purpose Serial Communication For GT01, GT11 and GT21 Error code Error name ER00 BCC error ER01 Format error ER02 NOT supported error ER03 Address error ER04 Receive buffer overflow ER05 Requested overflow ER06 Data error ER07 Data write inhibit error Measures The value of BCC may be incorrect. Check if there is no calculation mistake. A command format may be incorrect. Check if it is correct. A command used is not supported with the version of the GT.
Chapter 6 Specifications Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.
6.1 GT01 6.1.1 General Specifications Item Rated voltage Operating voltage range AIGT0030B AIGT0030H AIGT0130B AIGT0130H AIGT0230B AIGT0230H 24 V DC Specifications AIGT0032B AIGT0030B1 AIGT0032H AIGT0030H1 AIGT0132B AIGT0130B1 AIGT0132H AIGT0130H1 AIGT0232B AIGT0230B1 AIGT0232H AIGT0230H1 5 V DC AIGT0032B1 AIGT0032H1 AIGT0132B1 AIGT0132H1 AIGT0232B1 AIGT0232H1 21.6 to 26.4 V DC 4.5 to 5.
6.1.2 Performance Specifications (GT01) Contrast Specifications AIGT0030B1 AIGT0130B1 AIGT0230B1 AIGT0030H1 AIGT0130H1 AIGT0230H1 AIGT0030B AIGT0130B AIGT0230B AIGT0030H AIGT0130H AIGT0230H AIGT0032B1 AIGT0132B1 AIGT0232B1 AIGT0032H1 AIGT0132H1 AIGT0232H1 AIGT0032B AIGT0132B AIGT0232B AIGT0032H AIGT0132H AIGT0232H STN monochrome LCD 128 (W) x 64 (H) dots 70.38 (W) x 35.
6.1.3 Function Specifications (GT01) Item Displayable fonts Character types Number of registerable screens Registerable screen number Graphics Specifications Fixed (GTWIN): 1/4 width (8 x 8), half width (16 x 8), full width (16 x 16) (Double or quadruple in height and width) True Type (GTWIN): 10 to 64 dots Windows (R): 10 to 64 dots English, Japanese, Korean, German, French, Italian, Spanish, Simplified Chinese, Traditional Chinese characters and Turkish can be displayed.
6.1.
6.2 GT02 6.2.1 General Specifications (GT02) Item Specifications 24 V DC type Rated voltage Operating voltage range 24 V DC 21.6 to 26.4 V DC Power consumption 1.9 W or less (80 mA or less) Ambient temperature Ambient humidity Storage temperature Storage humidity 5 V DC 5 V DC 4.5 to 5.
6.2.2 Performance Specifications (GT02) Item Display device Resolution Displayable area Display GT02G Contrast 3-color LED bakclight (white, pink, 3-color LED backlight (green, red) orange, red) Backlight brightness can be adjusted on the menu screen or GTWIN configuration settings. (There are some minor variations in the backlight brightness.) Contrast can be adjusted on the menu screen.
6.2.
6.2.4 Interface Specifications (GT02) Interface for connecting PLC/External devices - COM port Specifications RS232C type RS422/RS485 type Communication standard Conforms to RS232C Conforms to RS422 (Non insulation type) (Non insulation type) Communication Baud rate (bit/s) 9600, 19200, 38400, 57600, 115200 bps condition with Data length (bit) 7, 8 external Parity None, Odd, Even devices Stop bit (bit) 1 Transmission distance Max. 15 m Max.
6.3 GT02L 6.3.1 General Specifications (GT02L) Item Rated voltage Operating voltage range Power consumption Ambient temperature Ambient humidity Storage temperature Storage humidity Specifications 5 V DC 4.5 to 5.
6.3.2 Performance Specifications (GT02L) Display Item Display device Resolution Displayable area Backlight Contrast LED bakclight (white) Backlight brightness can be adjusted on the menu screen or GTWIN configuration settings. (There are some minor variations in the backlight brightness.) Contrast can be adjusted on the menu screen. Touch switch Analog touch switch (resistive film type) Backlight brightness Touch switches Specifications STN monochrome LCD 160 (W) x 64 (H) dots 88.0 (W) x 35.
6.3.
6.3.4 Interface Specifications (GT02L) Interface for connecting PLC/External devices - COM port Specifications RS232C type RS422/RS485 type Communication standard Conforms to RS232C Conforms to RS422 (Non insulation type) (Non insulation type) Communication Baud rate (bit/s) 9600, 19200, 38400, 57600, 115200 bps condition with Data length (bit) 7, 8 external Parity None, Odd, Even devices Stop bit (bit) 1 Transmission distance Max. 15 m Max.
6.4 GT05 6.4.1 General Specifications Item Rated voltage Operating voltage range Power consumption Insulation method of power supply part Ambient temperature Ambient humidity Storage temperature Storage humidity Specifications GT05S 24 V DC 21.6 to 26.4 V DC 3.6 W or less (150 mA or less) GT05M/GT05G 2.
6.4.2 Performance Specifications (GT05) Item Display device Resolution Displayable area Backlight Specifications GT05M GT05G STN monochrome LCD 3-color LED 3-color LED bakclight backlight (green, (white, pink, red) orange, red) Backlight brightness can be adjusted on the menu screen or GTWIN configuration settings. (There are some minor variations in the backlight brightness.) Contrast can be adjusted on the menu screen.
6.4.3 Function Specifications (GT05) Item Displayable fonts Character types Number of registerable screens Registerable screen number Specifications GT05S GT05M/GT05G Fixed (GTWIN): 1/4 width (8 x 8), half width (16 x 8), full width (16 x 16) (Double, quadruple or octuple in height and width) True Type (GTWIN): 10 to 240 dots Windows (R): 10 to 240 dots English, Japanese, Korean, German, French, Italian, Spanish, Simplified Chinese, Traditional Chinese characters and Turkish can be displayed. Approx.
6.4.
6.5 GT11 6.5.1 General Specifications (GT11) Item Rated voltage Operating voltage range Power consumption Ambient temperature Ambient humidity Storage temperature Storage humidity Specifications 24 V DC 21.6 to 26.4 V DC 2.
6.5.2 Performance Specifications (GT11) Item Display Touch switches Display device Resolution Displayable area Backlight Backlight brightness Contrast Touch switch Touch switch operation Life Specifications AIGT2030B/AIGT2030H AIGT2130B/AIGT2130H AIGT2032B/AIGT2032H AIGT2132B/AIGT2132H STN monochrome LCD 240 (W) x 96 (H) dots 96.0 (W) x 35.4 (H) mm 3-color LED backlight 1-color LED backlight (white) (green, orange, red) Can be set on the menu screen or GTWIN configuration settings.
6.5.3 Function Specifications (GT11) Item Displayable fonts Character types Number of registerable screens Registerable screen number Graphics Specifications Fixed (GTWIN): 1/4 width (8 x 8), half width (16 x 8), full width (16 x 16) (Double or quadruple in height and width) True Type (GTWIN): 10 to 96 dots Windows (R): 10 to 96 dots English, Japanese, Korean, German, French, Italian, Spanish, Simplified Chinese, Traditional Chinese characters and Turkish can be displayed.
6.5.4 Interface Specifications (GT11) Interface for connecting PLC/External devices - COM port Specifications AIGT2030B/AIGT2030H AIGT2032B/AIGT2032H AIGT2130B/AIGT2130H AIGT2132B/AIGT2132H Communication standard Conforms to RS232C Conforms to RS422 (Non insulation type) (Non insulation type) Communication Baud rate (bit/s) 9600, 19200, 38400, 57600, 115200 bps condition with Data length (bit) 7, 8 external Parity None, Odd, Even devices Stop bit (bit) 1 Transmission distance Max. 15 m Max.
6.6 GT12 6.6.1 General Specifications (GT12) Item Rated voltage Operating voltage range Power consumption Insulation method of power supply part Ambient temperature Ambient humidity Storage temperature Storage humidity Specifications 24 V DC 21.6 to 26.4 V DC 1.
6.6.2 Performance Specifications (GT12) Item Display device Resolution Displayable area Gradation Display Backlight Backlight brightness Touch switches Contrast Touch switch Touch switch operation Life Specifications GT12M STN monochrome LCD 320 (W) x 120 (H) dots 108.78 (W) x 40.78 (H) mm GT12G 2 gradation/8 gradation (Selectable with GTWIN.
6.6.
6.6.4 Interface Specifications (GT12) Interface for connecting PLC/External devices - COM port Specifications AIG12*Q12D AIG12*Q14D Item AIG12*Q13D AIG12*Q15D RS232C type RS422/RS485 type Communication standard Conforms to RS232C Conforms to RS422 (Non insulation type) Note1) (Non insulation type) Note1) Communication Baud rate (bit/s) 9600, 19200, 38400, 57600, 115200 bps condition with Data length (bit) 7, 8 external Parity None, Odd, Even devices Stop bit (bit) 1 Transmission distance Max. 15 m Max.
6.7 GT21 6.7.1 General Specifications (GT21) Item Rated voltage Operating voltage range Power consumption Ambient temperature Ambient humidity Storage temperature Storage humidity Breakdown voltage Insulation resistance Vibration resistance Shock resistance EC Directive applicable Specifications 24 V DC 21.6 to 26.4 V DC 4.
6.7.2 Performance Specifications (GT21) Display Item Display device Resolution Displayable area Backlight Backlight brightness Contrast Touch switches Touch switch Touch switch operation Life Specifications 256-color STN color LCD 320 (W) x 240 (H) dots 98.0 (W) x 74.0 (H) mm 1-color LED backlight (white) Can be set on the menu screen or GTWIN configuration settings. (There are some minor variations in the backlight brightness.) Can be adjusted on the menu screen or GTWIN configuration settings.
6.7.3 Function Specifications (GT21) Item Displayable fonts Character types Number of registerable screens Registerable screen number Graphics Specifications Fixed (GTWIN): 1/4 width (8 x 8), half width (16 x 8), full width (16 x 16) (Double or quadruple in height and width) True Type (GTWIN): 10 to 240 dots Windows (R): 10 to 240 dots English, Japanese, Korean, German, French, Italian, Spanish, Simplified Chinese, Traditional Chinese characters and Turkish can be displayed.
6.7.4 Interface Specifications (GT21) Interface for connecting PLC/External devices - COM port Specifications AIGT2230B/AIGT2230H AIGT2232B/AIGT2232H Communication standard Conforms to RS232C Conforms to RS422 (Non insulation type) (Non insulation type) Communication Baud rate (bit/s) 9600, 19200, 38400, 57600, 115200 bps condition with Data length (bit) 7, 8 external Parity None, Odd, Even devices Stop bit (bit) 1 Transmission distance Max. 15 m Max.
6.8 GT32 6.8.1 General Specifications (GT32) Item Rated voltage Operating voltage range Power consumption Insulation method of power supply part Ambient temperature Ambient humidity Storage temperature Storage humidity Specifications GT32M GT32T0 GT32T1 24 V DC 21.6 to 26.
6.8.2 Performance Specifications (GT32) Item Display Display device Resolution Displayable area Backlight LCD life Contrast Touch switches Touch switch Touch switch operation Life Through function F-ROM Memory Specifications GT32M GT32T0 GT32T1 Blue-white STN monochrome LCD 4096-color TFT color LCD 320 (W) x 240 (H) dots 113.2 (W) x 86.4 (H) mm 110.8 (W) x 83.6 (H) mm CFL backlight 75000 hours (at 25 C) Note4) 50000 hours (at 25 C) Note4) Can be adjusted on the menu None screen.
6.8.3 Function Specifications (GT32) Item Displayable fonts Character types Number of registerable screens Registerable screen number Specifications GT32M GT32T0/GT32T1 Fixed (GTWIN): 1/4 width (8 x 8), half width (16 x 8), full width (16 x 16) (Double, quadruple or octuple in height and width) True Type (GTWIN): 10 to 240 dots Windows (R): 10 to 240 dots English, Japanese, Korean, German, French, Italian, Spanish, Simplified Chinese, Traditional Chinese characters and Turkish can be displayed. Approx.
6.8.
Ethernet port (GT32T1 only) Specifications GT32T1 Communication standard IEEE802.8u/100BASE-TX IEEE802.3/10BASE-T Note1) Connector shape Plug-in phone jack Note2) Transmission distance Max. 100 m Applicable cable UTP cable (Unshielded wire) Category 5 Note3) Auto MDI-X Supported Light on: During 100BASE-TX communication SPEED lamp Blinking: During 10BASE-TX communication Light on: When linked LINK/ACT lamp Blinking: During data reception.
6.9 GT32-E 6.9.1 General Specifications (GT32-E) Item Rated voltage Operating voltage range Power consumption Insulation method of power supply part Ambient temperature Ambient humidity Storage temperature Storage humidity Specifications GT32M-E 24 V DC 21.6 to 26.4 V DC 4.8 W or less (200 mA or less) GT32T-E 7.
6.9.2 Performance Specifications (GT32-E) Item Display Note1) Display device Resolution Displayable area Backlight Contrast Touch switches Touch switch Touch switch operation Life Specifications GT32M-E GT32T-E TFT color LCD TFT monochrome LCD 320 (W) x 240 (H) dots 115.2 (W) x 86.4 (H) mm 1-color LED backlight (white) Can be adjusted on the menu screen, GTWIN configuration settings or PLC. (There are some minor variations in the backlight brightness.) Analog touch switch (resistive film type) 0.
6.9.3 Function Specifications (GT32-E) Item Displayable fonts Character types Number of registerable screens Registerable screen number Specifications GT32M-E GT32T-E Fixed (GTWIN): 1/4 width (8 x 8), half width (16 x 8), full width (16 x 16) (Double, quadruple or octuple in height and width) True Type (GTWIN): 10 to 240 dots Windows (R): 10 to 240 dots English, Japanese, Korean, German, French, Italian, Spanish, Simplified Chinese, Traditional Chinese characters and Turkish can be displayed. Approx.
6.9.4 Interface Specifications (GT32-E) Interface for connecting PLC/External devices - COM port Specifications AIG32MQ03DE AIG32MQ05DE AIG32TQ03DE AIG32TQ05DE Communication standard Conforms to RS232C Conforms to RS422 (Non insulation type) Note1) (Non insulation type) Note1) Communication Baud rate (bit/s) 9600, 19200, 38400, 57600, 115200 bps condition with Data length (bit) 7, 8 external Parity None, Odd, Even devices Stop bit (bit) 1 Transmission distance Max. 15 m Max.
Chapter 7 Dimensions and Other Documentation 7-1 Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.
7.1 Dimensions 7.1.1 GT01/GT01R Installation dimensions Panel cutout dimensions Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.
7.1.2 GT02 Installation dimensions Panel cutout dimensions Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.
7.1.3 GT02L Installation dimensions Panel cutout dimensions Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.
7.1.4 GT05 Installation dimensions Panel cutout dimensions Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.
7.1.5 GT11 Installation dimensions Panel cutout dimensions Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.
7.1.6 GT12 Installation dimensions Panel cutout dimensions Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.
7.1.7 GT21 Installation dimensions Panel cutout dimensions Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.
7.1.8 GT32 GT32M Back view GT32T0 GT32T1 Installation dimensions Panel cutout dimensions Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.
7.1.9 GT32-E Installation dimensions Panel cutout dimensions Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.
7.2 Cable Specifications 7.2.1 AIGT8142 7.2.2 AIGT8152 7.2.3 AIGT8162/AIGT8165/AIGT8160 Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.
7.2.4 AIGT8175 7.2.5 AIP81842 Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.
7.3 Table of Screen Messages Table of GT screen messages In addition to screen data, the GT also displays the following messages. When transferring data from personal computer to a GT This is displayed when data is being transferred from the computer to the GT. When transferring data from GT to a personal computer This is displayed when data is being transferred from the GT to the computer. When there is no base screen data This is displayed when there is no base screen data.
7.
7.5 ASCII Code Table Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.
Record of changes Manual No. Date Desceiption of changes ARCT1F511E Jul.2010 First edition ARCT1F511E-1 Dec.2010 Second edition ARCT1F511E-2 Apr.2011 Third edition ARCT1F511E-3 Aug.2011 Forth edition - Added new model GT32-E - Error correction ARCT1F511E-4 Dec.2011 Fifth edition -Added vertical type display function ( GT05/GT32/GT32-E) -Added device change function Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.