Operating Instructions Camera Head Model No. GP-KS822H Camera Control Unit Model No. ON GP-KS822CU DC POW G ER P-KS 822 CU OFF AW C ATW MAN U STA RT WH IT BALE IMA G NOR ORIE E NT MAL BRIG ROTA HTN AU ESS MANTO U CAM ERA LIVE /FR E Cable : Option Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use.
We declare under our sole responsibility that the product to which this declaration relates is in conformity with the standards or other normative documents following the provisions of Directives EEC/73/23 and EEC/89/336. Wij verklaren als enige aansprakelijke, dat het product waarop deze verklaring betrekking heeft, voldoet aan de volgende normen of andere normatieve documenten, overeenkomstig de bepalingen van Richtlijnen 73/23/EEC en 89/336/EEC.
IMPORTANT SAFETY INSTRUCTIONS 1) Read these instructions. 2) Keep these instructions. 3) Heed all warnings. 4) Follow all instructions. 5) Do not use this apparatus near water. 6) Clean only with dry cloth. 7) Do not block any ventilation openings. Install in accordance with the manufacturer's instructions. 8) Do not use near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. 9) Do not misuse the polarized or grounding-type plug.
CONTENTS IMPORTANT SAFETY INSTRUCTIONS ......................................................................................................................................................3 FEATURES .................................................................................................................................................................................................5 PREFACE .............................................................................................................
PREFACE FEATURES Panasonic's GP-KS822CU and GP-KS822H Industrial Color Camera overcomes space limitations that have complicated many video applications. Weight of only 14 g {0.035 lbs}, this remarkably compact camera measures only two-thirds of an inch in diameter and less than two inches in length. With the 380 000-pixel for NTSC (440 000-pixel for PAL), 1/2-inch CCD pick-up device, horizontal resolution is more than 480 lines, and signal-to-noise ratio is 50 dB.
PRECAUTIONS • Do not attempt to disassemble the camera. To prevent electric shock, do not remove screws or cover. There are no user-serviceable parts inside. Refer servicing to qualified service personnel. • How to take care of this camera. After turning OFF the DC power switch, clean it with a dry cloth. If it is difficult to remove the dirt or dust, clean it up with a cloth applied the neutral cleanser. Use the lens cleaning tissue paper(may be available at your local camera store) for lens cleaning.
SYSTEM BLOCK DIAGRAM GP-KS822 Standard Configuration Camera Head, Tripod Attachment, Camera Control Unit. GP-KS822H FOCUS LOCK Optional Camera Cable GP-CA162/2: 2 m GP-CA162/38: 3.8 m WHITE BAL. DC POWER ON OFF AWC ATW MANU BRIGHTNESS GP-KS822 AUTO ROTA. MANU CAMERA START R Camera Head (GP-KS822H) IMAGE ORIENT. NORM.
Camera Control Unit GP-KS822CU o Brightness control knob This controls the ELC & AGC of the target level or video level. q DC Power On/Off Switch (DC POWER, ON/OFF) w Auto White Balance Control Button (AWC START) The white balance can be set by pressing this button when the White Balance Selection Switch (r) is set to the AWC position. !0 Camera Cable Connector (CAMERA) This 16-pin connector is used for connection of camera cable.
on off !9/@0 Light Measurement Area Selection Switch The back light sensing zone can be set in the BRIGHTNESS AUTO mode. 00: OFF (All of the screen) 01: Preset 1 (Pattern 1 Sensing Zone) 10: Preset 2 (Pattern 2 Sensing Zone) Sensing Zone Preset 1 Preset 2 11: Automatic Sensing Zone (The sensing zone is automatically set according to the object.) on off @1 Aperture Level Selection Switch The aperture level can be selected by this switch. High level can be obtained by turning on this switch.
PREPARATIONS Caution: Keep the DC Power switch of the camera in the OFF position through the installation. GP-KS822H with GP-AD22TA and optional Cmount lens 1. Remove the front cap of the camera head and confirm that the surface of the optical filter of the camera head is clean. GP-KS822H with GP-LM3TA, GP-LM7TA, GPLM15TA or GP-LP12TA 1. Remove the front cap of the camera and confirm that the surface of the optical filter of the camera head is clean.
SPECIFICATIONS Pick-up Device : Horizontal Resolution : Minimum Scene Illumination : Signal to Noise Ratio : Video Output : Scanning System : Synchronization : White Balance : AGC: ELC: Brightness: Light Measurement Area: Image Orientation: Freeze: Aperture Compensation: Function Switches: Controls: Power Source : Camera Cable Length : Ambient Temperature : Dimensions : Weight : For NTSC : 1/2-inch Interline transfer CCD image sensor with 768 (H) x 494 (V) pixels For PAL : 1/2-inch Interline transfer CCD
For U.S., Canadian and Puerto Rican fields: Panasonic System Solutions Company, Unit Company of Panasonic Corporation of North America Security Systems www.panasonic.com/security For customer support, call 1.877.733.3689 Executive Office: Three Panasonic Way 2H-2, Secaucus, New Jersey 07094 Zone Office Eastern: Three Panasonic Way, Secaucus, New Jersey 07094 Central: 1707 N. Randal Road, Elgin, IL 60123 Southern: 1225 Northbrook Parkway, Suwanee, GA 30024 Western: 6550 Katella Ave.