Datasheet

185
Digital Fiber Sensor FX-300 SERIES
Selection
Guide
Fibers
Ampliers
FX-500
FX-100
FX-300
FX-410
FX-311
FX-301-F7/
FX-301-F
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
CONTROL
DEVICES
ENDOSCOPE
LASER
MARKERS
PLC /
TERMINALS
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
LIST OF FIBERS
FX-301 / FX-305 (Red LED type) sensing range (Note 1)
Retroreective type
The FX-305 and FX-301(-HS) have different sensing modes.
FX-305: H-SP, FAST, STD, STDF, LONG, U-LG (no S-D mode)
FX-301(-HS): S-D, H-SP (Note 1), FAST, STD, LONG (no STDF or U-LG mode)
Model No.
Sensing range (mm in) (Note 2, 3)
Dimensions
Red LED
U-LG LONG STDF STD FAST H-SP S-D
FR-KV1
15 to 370 0.591 to 14.567 15 to 330 0.591 to 12.992
15 to 240 0.591 to 9.449 15 to 210 0.591 to 8.268 15 to 170 0.591 to 6.693
15 to 80 0.591 to 3.150 15 to 90 0.591 to 3.543
P.98
FR-KZ21
20 to 200 0.787 to 7.874 20 to 200 0.787 to 7.874 20 to 200 0.787 to 7.874 20 to 200 0.787 to 7.874 20 to 200 0.787 to 7.874 20 to 200 0.787 to 7.874 20 to 200 0.787 to 7.874
P.98
FR-KZ21E
20 to 200 0.787 to 7.874 20 to 200 0.787 to 7.874 20 to 200 0.787 to 7.874 20 to 200 0.787 to 7.874 20 to 200 0.787 to 7.874 20 to 200 0.787 to 7.874 20 to 200 0.787 to 7.874
P.98
FR-WKZ11
100 to 910 3.937 to 35.827 100 to 730 3.937 to 28.740 100 to 600 3.937 to 23.622 100 to 520 3.937 to 20.472 100 to 460 3.937 to 18.110
P.98
Notes: 1) Refer to p.35~ for the sensing ranges for the FX-301-HS in H-SP mode.
2) Note that the sensing range of the free-cut type ber may be reduced by 20 % max. depending upon how the ber is cut.
The sensing range of FR-WKZ11 is specied for the RF-13. The sensing range of FR-KZ21 and FR-KZ21E is specied for the attached reector RF-003.
The sensing range of FR-KV1 is specied for the attached reector.
3) The sensing range of retroreective type is the possible setting range for the attached reector. The ber can detect an object less than setting range for
the reector. However, note that if there are any white or highly-reective surfaces near the ber head, reected incident light may affect the ber head. If
this occurs, adjust the threshold value of the amplier unit before use.
Fibers are listed in alphabetic order. Refer to p.5~ “Fiber Selection” for details of each ber.
Reective type
FX-301 / FX-305 (Red LED type) sensing range (Note 1)
The FX-305 and FX-301(-HS) have different sensing modes.
FX-305: H-SP, FAST, STD, STDF, LONG, U-LG (no S-D mode)
FX-301(-HS): S-D, H-SP (Note 1), FAST, STD, LONG (no STDF or U-LG mode)
Model No.
Sensing range (mm in) (Note 2, 3)
Dimensions
Red LED
U-LG LONG STDF STD FAST H-SP S-D
FD-30
170 6.693 110 4.331 70 2.756 50 1.969 40 1.575 20 0.787 18 0.709
P.99
FD-31
150 5.906 95 3.740 63 2.480 45 1.772 35 1.378 17 0.669 16 0.630
P.99
FD-40
170 6.693 110 4.331 70 2.756 50 1.969 40 1.575 20 0.787 18 0.709
P.99
FD-41
150 5.906 95 3.740 63 2.480 45 1.772 35 1.378 17 0.669 16 0.630
P.99
FD-60
500 19.685 350 13.780 240 9.449 160 6.299 130 5.118 70 2.756 70 2.756
P.99
FD-61
440 17.323 320 12.598 205 8.071 145 5.709 105 4.134 65 2.559 60 2.362
P.99
FD-A15
230 9.055 200 7.874 150 5.906 150 5.906 100 3.937 45 1.772 50 1.969
P.99
FD-AFM2
290 11.417 220 8.661 135 5.315 110 4.331 78 3.071 35 1.378 39 1.535
P.99
FD-AFM2E
290 11.417 220 8.661 135 5.315 110 4.331 78 3.071 35 1.378 39 1.535
P.99
FD-B8
600 23.622 480 18.898 280 11.024 220 8.661 160 6.299 85 3.346 75 2.953
P.99
FD-E12
15 0.591 11 0.433 8 0.315 6 0.236 4 0.157 2 0.079 1 0.039
P.100
FD-E22
65 2.559 45 1.772 28 1.102 23 0.906 17 0.669 8 0.315 7 0.276
P.100
FD-EG1
50 1.969 38 1.496 25 0.984 18 0.709 14 0.551 5 0.197 6 0.236
P.100
FD-EG2
40 1.575 25 0.984 14 0.551 12 0.472 9 0.354 3 0.118 5 0.197
P.100
FD-EG3
20 0.787 15 0.591 9 0.354 8 0.315 5 0.197 2.5 0.098 3 0.118
P.100
FD-EN500S1
6.5 0.256 5 0.197 3 0.118 3 0.118 2 0.079 Cannot use Cannot use
P.100
FD-ENM1S1
50 1.969 38 1.496 20 0.787 18 0.709 14 0.551 5 0.197 6 0.236
P.100
FD-F4
Applicable pipe diameter: Outer dia. ø6 to ø26 mm ø0.236 to ø1.024 in transparent pipe
[PFA (uorine resin) or equivalently transparent pipe, wall thickness 1 mm 0.039 in]
P.100
FD-F41
Applicable pipe diameter: Outer dia. ø6 to ø26 mm ø0.236 to ø1.024 in transparent pipe
[PVC (vinyl chloride), uorine resin, polycarbonate, acrylic, glass, wall thickness 1 to 3 mm 0.039 to 0.118 in]
P.100
FD-F41Y
ø4 mm ø0.157 in form Protective tube: uorine resin, length 500 mm 19.685 in (cuttable)
Liquid surface not contacted: Beam received, Liquid surface contacted: Beam interrupted
P.101
FD-F8Y
P.101
FD-FA90
Applicable pipe diameter: Outer dia. ø8 mm ø0.315 in or more transparent pipe (When used with the tying bands: ø8 to ø80 mm ø0.315 to ø3.150 in) [PFA (uorine resin), including translucent]
Liquid absent: Beam received, Liquid present: Beam interrupted
P.101
FD-FM2
410 16.142 310 12.205 200 7.874 140 5.512 100 3.937 55 2.165 47 1.850
P.101
FD-FM2S
370 14.567 270 10.630 170 6.693 110 4.331 85 3.346 45 1.772 39 1.535
P.101
FD-FM2S4
370 14.567 270 10.630 170 6.693 110 4.331 85 3.346 45 1.772 39 1.535
P.101
FD-G4
150 5.906 110 4.331 65 2.559 55 2.165 42 1.654 15 0.591 19 0.748
P.101
FD-G6
150 5.906 110 4.331 65 2.559 55 2.165 42 1.654 15 0.591 19 0.748
P.102
FD-G6X
150 5.906 90 3.543 48 1.890 45 1.772 35 1.378 12 0.472 20 0.787
P.102
FD-G40
150 5.906 110 4.331 65 2.559 55 2.165 42 1.654 15 0.591 19 0.748
P.101
FD-G60
410 16.142 310 12.205 200 7.874 140 5.512 100 3.937 55 2.165 47 1.850
P.102
FD-H13-FM2
410 16.142 310 12.205 200 7.874 140 5.512 100 3.937 55 2.165 47 1.850
P.102
FD-H18-L31
0 to 20 0 to 0.787 0 to 15 0 to 0.591 0 to 10 0 to 0.394 0 to 10 0 to 0.394
1 to 8 0.039 to 0.315
Cannot use
2 to 6 0.079 to 0.236
P.102
Notes: 1) Refer to p.35~ for the sensing ranges for the FX-301-HS in H-SP mode.
2) The standard sensing objects of the sensing ranges vary depending on the bers.
3) Note that the sensing range of the free-cut type ber may be reduced by 20 % max. depending upon how the ber is cut.
Fibers are listed in alphabetic order. Refer to p.5~ “Fiber Selection” for details of each ber.