Datasheet

Digital Fiber Sensor FX-300 SERIES
200
Selection
Guide
Fibers
Ampliers
FX-500
FX-100
FX-300
FX-410
FX-311
FX-301-F7/
FX-301-F
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
CONTROL
DEVICES
ENDOSCOPE
LASER
MARKERS
PLC /
TERMINALS
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
PRECAUTIONS FOR PROPER USE
Refer to General precautions, p.80~ for ber precautions, and to the “PRO mode operation
guide” on our website for details pertaining to operating instructions for the amplier.
Peripheral units that can be combined
Function table for FX-300 series
Previous models New models
Standard type
High-function type
High-speed type Standard type High-speed type
High-function type
FX-301(P)
(Previous version unit)
FX-302(P) FX-303(P)
FX-301(P)
(Updated version unit)
FX-301
(P)
-HS
FX-305(P)
Four-chemical emitting element + APC circuit
No No No
Yes Yes Yes
Four-chemical emitting element only
Yes (Note) Yes Yes
Light emitting amount selection function
No No No
Yes Yes Yes
Reduced intensity mode (S-D)
Yes (Note) Yes
No
Yes Yes
9,999 digit display
No No No No No
Yes
Response time (Max. speed)
150 μs 300 μs 90 μs 65 μs 35 μs 65 μs
Interference prevention function (Effective no. of units)
Incorporated (4) Incorporated (8)
Not incorporated (0)
Incorporated (4)
Not incorporated (0)
Incorporated (16)
Independent 2 outputs
No No No No No
Yes
Alarm output function
No No No No No
Yes
Error output function
No No No No No
Yes
Differential sensing
No No No No No
Yes
Window comparator mode
No
Yes
No No No
Yes
Bank selection unit
FX-CH(-P)
Yes Yes
No No No No
External input unit
FX-CH2(-P)
No No No
Yes
No
Yes
Upper communication unit
SC-GU1-485
No No No
Yes
No
Yes
Note: Except FX-301B/G/H.
Wiring Key-lock function
Make sure that the power supply is off while wiring.
Verify that the supply voltage variation is within the rating.
• Take care that if a voltage exceeding the rated range is
applied, or if an AC power supply is directly connected,
the product may get burnt or damaged.
If power is supplied from a commercial switching
regulator, ensure that the frame ground (F.G.) terminal of
the power supply is connected to an actual ground.
In case noise generating equipment (switching regulator,
inverter motor, etc.) is used in the vicinity of this
product, connect the frame ground (F.G.) terminal of the
equipment to an actual ground.
Take care that short circuit of the load wrong wiring may
burn or damage the product.
Do not run the wires together with high-voltage lines or
power lines or put them in the same raceway. This can
cause malfunction due to induction.
Make sure to use an isolation transformer for the DC
power supply. If an autotransformer (single winding
transformer) is used, this product or the power supply
may get damaged.
Make sure to use the optional quick-connection cable for
the connection of the amplier. Extension up to total 100
m 328.084 ft is possible with 0.3 mm
2
, or more, cable.
(5-8 unit expansion: 50 m 164.042 ft, 9-16 unit
expansion: 20 m 65.617 ft) However, in order to reduce
noise, make the wiring as short as possible.
Note that the residual voltage will increase when the
cable is extended.
If jog switch and MODE key are pressed for more than
2 sec. at the same time in ‘RUN’ mode condition, the
key operations are locked, and only the threshold value
conrmation function or the adjust function (valid only
when the adjust lock function is canceled) is valid.
To cancel the lock function, press both the keys for more
than 2 sec. once again.
Others
When the emission halt of the light emitting amount
selection function is set from “OFF” to “ON”, the output
may be unstable. Do not use the output control for 0.5
sec. after starting emission.
Do not use during the initial transient time (0.5 sec.) after
the power supply is switched on.
• Take care that the sensor is not directly exposed to
uorescent lamp from a rapid-starter lamp, a high
frequency lighting device or sunlight etc. , as it may affect
the sensing performance.
• Do not use this sensor in places having excessive vapor,
dust, etc., or where it may come in contact with corrosive
gas.
Take care that the product does not come in direct
contact with water, oil, grease, or organic solvents, such
as, thinner, etc.
This sensor cannot be used in an environment containing
inammable or explosive gases.
Never disassemble or modify the sensor.
Note: 3 seconds or more for FX-301B/G/H(P).