Datasheet
Digital Fiber Sensor FX-300 SERIES
192
Selection
Guide
Fibers
Ampliers
FX-500
FX-100
FX-300
FX-410
FX-311
FX-301-F7/
FX-301-F
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
CONTROL
DEVICES
ENDOSCOPE
LASER
MARKERS
PLC /
TERMINALS
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
FIBER OPTIONS
Lens (for reective type ber)
Designation Model No. Description
For reective type ber
Pinpoint
spot lens
FX-MR1
Pinpoint spot of ø0.5 mm ø0.020 in. Enables detection of minute objects or small marks.
• Distance to focal point: 6 ±1 mm 0.236 ±0.039 in
• Applicable bers: FD-WG4, FD-G4
• Ambient temperature: –
40 to +70 °C –
40 to +158 °F (Note 2)
Zoom lens
FX-MR2
The spot diameter is adjustable
from ø0.7 to ø2 mm ø0.028 to
ø0.079 in according to how
much the ber is screwed in.
• Applicable bers:
FD-WG4, FD-G4
• Ambient temperature:
–
40 to +70 °C
–
40 to +158 °F (Note 2)
• Accessory: MS-EX-3
(mounting bracket)
Sensing range for red LED type (Note 1)
Screw-in depth
Distance to focal point
Spot diameter
7 mm 0.276 in
ø18.5 mm ø0.728 in approx.
ø0.7 mm ø0.028 in
12 mm 0.472 in
ø27 mm ø1.063 in approx.
ø1.2 mm ø0.047 in
14 mm 0.551 in
ø43 mm ø1.693 in approx.
ø2.0 mm ø0.079 in
Finest
spot lens
FX-MR3
Distance to
focal point
Spot diameter
Extremely ne spot of ø0.3 mm
ø0.012 in approx. achieved.
• Applicable bers:
FD-WG4, FD-G4,
FD-EG1, FD-EG2,
FD-EG3, FD-G6X,
FD-G6
• Ambient temperature:
– 40 to +70 °C
– 40 to +158 °F (Note 2)
Sensing range for red LED type (Note 1)
Fiber
Distance to focal point
Spot diameter
FD-EG3
7.5 ±0.5 mm 0.295 ±0.020 in
ø0.15 mm ø0.006 in approx
FD-EG2
7.5 ±0.5 mm 0.295 ±0.020 in
ø0.2 mm ø0.008 in approx
FD-EG1
7.5 ±0.5 mm 0.295 ±0.020 in
ø0.3 mm ø0.012 in approx
FD-WG4/G4/G6X/G6
7.5 ±0.5 mm 0.295 ±0.020 in
ø0.5 mm ø0.020 in approx
Finest spot
lens
FX-MR6
Extremely ne spot of ø0.1 mm
ø0.004 in approx. achieved.
• Applicable bers:
FD-WG4, FD-G4,
FD-EG1, FD-EG2,
FD-EG3, FD-G6X,
FD-G6
• Ambient temperature:
–20 to +60 °C
– 4 to +140 °F (Note 2)
Sensing range for red LED type (Note 1)
Fiber
Distance to focal point
Spot diameter
FD-EG3
7 ±0.5 mm 0.276 ±0.020 in
ø0.1 mm ø0.004 in approx
FD-EG2
7 ±0.5 mm 0.276 ±0.020 in
ø0.15 mm ø0.006 in approx
FD-EG1
7 ±0.5 mm 0.276 ±0.020 in
ø0.2 mm ø0.008 in approx
FD-WG4/G4/G6X/G6
7 ±0.5 mm 0.276 ±0.020 in
ø0.4 mm ø0.016 in approx
Zoom lens
Side-view
type
FX-MR5
Screw-in depth
Spot diameter
Distance
to focal
point
FX-MR2 is converted into a
side-view type and can be
mounted in a very small space.
• Applicable bers:
FD-WG4, FD-G4
• Ambient temperature:
– 40 to +70 °C
– 40 to +158 °F (Note 2)
Sensing range for red LED type (Note 1)
Screw-in depth
Distance to focal point
Spot diameter
8 mm 0.315 in
13 mm 0.512 in approx.
ø0.5 mm ø0.020 in
10 mm 0.394 in
15 mm 0.591 in approx.
ø0.8 mm ø0.031 in
14 mm 0.551 in
30 mm 1.181 in approx.
ø3.0 mm ø0.118 in
Screw-in
depth
Distance to
focal point
Spot
diameter
Notes: 1)
The sensing ranges are the values when used in combination with red LED type amplier. Please contact our ofce for details on sensing ranges for other types of amplier.
2) Refer p.76~ for the ambient temperatures of bers to be used in combination.
Others
Designation Model No. Description
Protective tube
(For thru-beam
type ber)
FTP-500 (0.5 m 1.641 ft)
For
M4
thread
Applicable bers
FT-42
FT-B8
FT-FM2
FT-FM2S
FT-FM2S4
FT-H13-FM2
FT-P60
FT-P80
The protective
tube, made of
noncorrosive
stainless steel,
protects the
inner ber
cable from
any external
forces.
FTP-1000 (1 m 3.281 ft)
FTP-1500 (1.5 m 4.922 ft)
FTP-N500 (0.5 m 1.641 ft)
For
M3
thread
FT-31
FT-NFM2
FT-NFM2S
FT-NFM2S4
FT-P40
FT-T80
FD-P40
FD-T40
FTP-N1000 (1 m 3.281 ft)
FTP-N1500 (1.5 m 4.922 ft)
Protective tube
(For reective
type ber)
FDP-500 (0.5 m 1.641 ft)
For
M6
thread
FD-61
FD-B8
FD-FM2
FD-FM2S
FD-FM2S4
FD-H13-FM2
FD-P80
FDP-1000 (1 m 3.281 ft)
FDP-1500 (1.5 m 4.922 ft)
FDP-N500 (0.5 m 1.641 ft)
For
M4
thread
FD-41
FD-NFM2
FD-NFM2S
FD-NFM2S4
FD-T80
FDP-N1000 (1 m 3.281 ft)
FDP-N1500 (1.5 m 4.922 ft)
Fiber bender FB-1
The ber bender bends the sleeve part of the
ber head at the proper radius. (Note 1)
Universal sensor
mounting stand (Note 2)
MS-AJ1-F
Horizontal mounting type
Mounting stand assembly for ber
(For M3,M4 or M6 threaded head ber)
MS-AJ2-F
Vertical mounting type
Single core
holder
FX-AT15A
The incident light intensity may vary when using a multi-core ber or a thin type sharp
bending ber. This holder suppresses the variation in the incident light intensity. Brown.
Notes: 1) Do not bend the sleeve part of any side-view type ber or ultra-small diameter head type ber.
2) Refer to the universal sensor mounting stand MS-AJ series pages for details.
Protective tube
• FTP-
□
• FDP-□
Universal sensor mounting stand
Using the arm which enables adjustment in the horizontal direction,
sensing can also be done from above an assembly line.
Fiber bender
• FB-1
• MS-AJ1-F
• MS-AJ2-F
Swivel: 360° rotation
360°
Angle adjustment: ±20°
20°
20°
Height adjustment:
150 mm 5.906 in approx.
Mounting hole for M6 screw
Forward / back adjustment:
130 mm 5.118 in approx
Swivel: 360° rotation
360°
Angle adjustment: ±20°
20°
20°
Height adjustment:
150 mm 5.906 in approx.
Mounting hole for M6 screw
Forward / back adjustment:
130 mm 5.118 in approx
• FX-AT15A
Single core holder