Datasheet

191
Digital Fiber Sensor FX-300 SERIES
Selection
Guide
Fibers
Ampliers
FX-500
FX-100
FX-300
FX-410
FX-311
FX-301-F7/
FX-301-F
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
CONTROL
DEVICES
ENDOSCOPE
LASER
MARKERS
PLC /
TERMINALS
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
FIBER OPTIONS
Lens (for thru-beam type ber)
Designation Model No. Description
For thru-beam type ber
Expansion
lens
(Note 1)
FX-LE1
Increases the sensing
range by 5 times or
more.
Ambient
temperature:
–60 to +350 °C
–76 to +662 °F
(Note 5)
Sensing range for red LED type (mm) [Lens on both sides] (Note 3)
Mode
Fiber
U-LG LONG STDF STD FAST S-D H-SP
FT-B8
3,500 (Note 2) 3,500 (Note 2)
3,000 2,500 2,000 1,000 1,000
FT-FM2
3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2)
2,500 1,300 1,000
FT-T80
3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2)
2,500 1,300 1,000
FT-R80
3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2)
2,300 1,600 800 750
FT-W8
3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2)
2,900 2,000 1,000 900
FT-P80
3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2)
2,500 1,100 1,000
FT-P60
3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2)
1,500 900 800
FT-P81X
1,600 (Note 2) 1,600 (Note 2) 1,600 (Note 2) 1,600 (Note 2) 1,600 (Note 2)
1,100 950
FT-H35-M2
3,500 (Note 2) 3,500 (Note 2)
2,500 2,000 1,500 750 700
FT-H20W-M1
1,600 (Note 2) 1,600 (Note 2) 1,600 (Note 2)
1,300 900 500 400
FT-H20-M1
1,600 (Note 2) 1,600 (Note 2) 1,600 (Note 2) 1,600 (Note 2)
1,100 900 600
Super-
expansion
lens
(Note 1)
FX-LE2
Tremendously
increases the sensing
range with large
diameter lenses.
Ambient
temperature:
–60 to +350 °C
–76 to +662 °F
(Note 5)
Sensing range for red LED type (mm) [Lens on both sides] (Note 3)
Mode
Fiber
U-LG LONG STDF STD FAST S-D H-SP
FT-B8
3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2)
FT-FM2
3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2)
FT-R80
3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2)
FT-W8
3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2)
FT-P80
3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2)
FT-P60
3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2)
FT-P81X
1,600 (Note 2) 1,600 (Note 2) 1,600 (Note 2) 1,600 (Note 2) 1,600 (Note 2) 1,600 (Note 2) 1,600 (Note 2)
FT-H35-M2
3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2)
FT-H20W-M1
1,600 (Note 2) 1,600 (Note 2) 1,600 (Note 2) 1,600 (Note 2) 1,600 (Note 2)
1,500
1,600 (Note 2)
FT-H20-M1
1,600 (Note 2) 1,600 (Note 2) 1,600 (Note 2) 1,600 (Note 2) 1,600 (Note 2) 1,600 (Note 2) 1,600 (Note 2)
FT-H13-FM2
3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2) 3,500 (Note 2)
Side-view
lens
FX-SV1
Beam axis is bent by
90°.
Ambient
temperature:
–60 to +300 °C
–76 to +572 °F
(Note 5)
Sensing range for red LED type (mm) [Lens on both sides] (Note 3)
Mode
Fiber
U-LG LONG STDF STD FAST S-D H-SP
FT-B8 1,450 1,100 660 530 400 186 180
FT-FM2 1,800 1,200 810 600 440 210 210
FT-T80 1,800 1,200 810 600 440 210 210
FT-W8 1,300 900 600 450 330 160 160
FT-P80 1,800 1,200 810 600 440 210 210
FT-P60 850 650 400 300 200 130 120
FT-P81X 1,800 1,200 810 600 440 200 200
FT-H35-M2
840 550 370 280 200 90 90
FT-H20W-M1
400 310 180 140 100 50 50
FT-H20-M1
840 550 370 280 200 90 90
Expansion
lens for
vacuum
ber
(Note 1)
FV-LE1
Sensing range increases
by 4 times or more.
Ambient temperature:
–60 to +350 °C
–76 to +662 °F (Note 5)
Sensing range for red LED type (mm) [Lens on both sides] (Note 3, 4)
Mode
Fiber
U-LG LONG STDF STD FAST S-D H-SP
FT-H30-M1V-S
1,600 1,200 650 450 300 150 200
Vacuum
resistant
side-view
lens
(Note 1)
FV-SV2
Beam axis is bent by
90°.
Ambient temperature:
–60 to +300 °C
–76 to +572 °F (Note 5)
Sensing range for red LED type (mm) [Lens on both sides] (Note 3, 4)
Mode
Fiber
U-LG LONG STDF STD FAST S-D H-SP
FT-H30-M1V-S
1,600 1,200 650 450 300 150 200
Notes: 1) Be careful when installing the thru-beam type ber equipped with the expansion lens, as the beam envelope becomes narrow and alignment is difcult.
Especially when installing a ber with many cores (sharp bending bers and heat-resistant glass ber), please be sure to use it only after you have
adjusted it sufciently.
2) The ber cable length practically limits the sensing range to 3,500 mm 137.795 in long (FT-P81X, FT-H20W-M1 and FT-H20-M1: 1,600 mm 62.992 in).
3) The sensing ranges are the values for red LED type amplier. Please contact our ofce for details on sensing ranges for other types of ampliers.
4) The ber cable length for the FT-H30-M1V-S is 1 m 3.281 ft. The sensing ranges in U-LG and LONG modes take into account the length of the FT-J8
atmospheric side ber.
5) Refer to p.76~ for the ambient temperatures of bers to be used in combination.