Retroreective type
Model No.
Sensing range (mm in) (Note 1, 2)
Dimensions
FX-301B FX-301G FX-301H
LONG STD FAST LONG STD FAST LONG STD FAST
FR-KV1
– – – – – – – – –
P.98
FR-KZ21
20 to 200 0.787 to 7.874 20 to 120 0.787 to 4.724 20 to 90 0.787 to 3.543 20 to 130 0.787 to 5.118 20 to 80 0.787 to 3.150 20 to 50 0.787 to 1.969 20 to 130 0.787 to 5.118 20 to 70 0.787 to 2.756
–
P.98
FR-KZ21E
20 to 160 0.787 to 6.299 20 to 100 0.787 to 3.937 20 to 60 0.787 to 2.362 20 to 110 0.787 to 4.331
– –
20 to 90 0.787 to 3.543
– –
P.98
FR-WKZ11
– – – – – –
100 to 340 3.937 to 13.386
– –
P.98
Notes: 1) Note that the sensing range of the free-cut type ber may be reduced by 20 % max. depending upon how the ber is cut.
2) The sensing range of retroreective type is the possible setting range for the attached reector. The ber can detect an object less than setting range for
the reector. However, note that if there are any white or highly-reective surfaces near the ber head, reected incident light may affect the ber head.
If this occurs, adjust the threshold value of the amplier unit before use.
Fibers are listed in alphabetic order. Refer to p.5~ “Fiber Selection” for details of each ber.
Reective type
Model No.
Sensing range (mm in) (Note 1, 2)
Dimensions
FX-301B FX-301G FX-301H
LONG STD FAST LONG STD FAST LONG STD FAST
FD-30
19 0.748 9 0.354 6 0.236 9 0.354 4.5 0.177 2.5 0.098 8 0.315 4 0.157 2.5 0.098 P.99
FD-31
18 0.709 8 0.315 5 0.197 8 0.315 4 0.157 2 0.079 7 0.276 3 0.118 2 0.079 P.99
FD-40
19 0.748 9 0.354 6 0.236 9 0.354 4.5 0.177 2.5 0.098 8 0.315 4 0.157 2.5 0.098 P.99
FD-41
18 0.709 8 0.315 5 0.197 8 0.315 4 0.157 2 0.079 7 0.276 3 0.118 2 0.079 P.99
FD-60
55 2.165 28 1.102 18 0.709 30 1.181 15 0.591 10 0.394 30 1.181 15 0.591 10 0.394 P.99
FD-61
48 1.890 24 0.945 16 0.630 26 1.024 13 0.512 8 0.315 27 1.063 12 0.472 8 0.315 P.99
FD-A15
25 0.984 15 0.591
– – – – – – –
P.99
FD-AFM2
40 1.575 20 0.787 13 0.512 18 0.709 9 0.354 5 0.197 12 0.472 6 0.236 4 0.157 P.99
FD-AFM2E
40 1.575 20 0.787 13 0.512 18 0.709 9 0.354 5 0.197 12 0.472 6 0.236 4 0.157 P.99
FD-B8
80 3.150 40 1.575 26 1.024 42 1.654 21 0.827 14 0.551 26 1.024 13 0.512 9 0.354 P.99
FD-E12
2 0.079 1 0.039
–
1 0.039
– –
1 0.039
– –
P.100
FD-E22
6 0.236 3 0.118 2 0.079 3 0.118 1.5 0.059 1 0.039 6 0.236 3 0.118 2 0.079 P.100
FD-EG1
6 0.236 3 0.118 2 0.079 3 0.118 1.5 0.059 1 0.039 10 0.394 5 0.197 3 0.118 P.100
FD-EG2
5 0.197 2 0.079 1 0.039 2 0.079 1 0.039
–
6 0.236 3 0.118 2 0.079 P.100
FD-EG3
2 0.079 1 0.039
–
1 0.039
– –
3 0.118 1.5 0.059 1 0.039 P.100
FD-EN500S1
– – – – – – – – –
P.100
FD-ENM1S1
6 0.236 3 0.118 2 0.079 3 0.118 1.5 0.059 1 0.039 4 0.157 2 0.079 1.5 0.059 P.100
FD-F4
Applicable pipe diameter: Outer dia. ø6 to ø26 mm ø0.236 to ø1.024 in transparent pipe
[PFA (uorine resin) or equivalently transparent pipe, wall thickness 1 mm 0.039 in]
P.100
FD-F41
Applicable pipe diameter: Outer dia. ø6 to ø26 mm ø0.236 to ø1.024 in transparent pipe
[PVC (vinyl chloride), uorine resin, polycarbonate, acrylic, glass, wall thickness 1 to 3 mm 0.039 to 0.118 in]
P.100
FD-F41Y
ø4 mm ø0.157 in form Protective tube: uorine resin, length 500 mm 19.685 in (cuttable)
Liquid surface not contacted: Beam received, Liquid surface contacted: Beam interrupted
P.101
FD-F8Y
– – – – – – – – –
P.101
FD-FA90
Applicable pipe diameter: Outer dia. ø8 mm ø0.315 in or more transparent pipe (When used with the tying bands: ø8 to ø80 mm ø0.315 to ø3.150 in) [PFA (uorine resin), including translucent]
Liquid absent: Beam received, Liquid present: Beam interrupted
P.101
FD-FM2
46 1.811 23 0.906 15 0.591 24 0.945 12 0.472 8 0.315 20 0.787 10 0.394 7 0.276 P.101
FD-FM2S
46 1.811 23 0.906 15 0.591 24 0.945 12 0.472 8 0.315 20 0.787 10 0.394 7 0.276 P.101
FD-FM2S4
46 1.811 23 0.906 15 0.591 24 0.945 12 0.472 8 0.315 20 0.787 10 0.394 7 0.276 P.101
FD-G4
22 0.866 11 0.433 8 0.315 12 0.472 6 0.236 4 0.157 7 0.276 3.5 0.138 2 0.079 P.101
FD-G6
22 0.866 11 0.433 8 0.315 12 0.472 6 0.236 4 0.157 7 0.276 3.5 0.138 2 0.079 P.102
FD-G6X
33 1.299 11 0.433 6 0.236 12 0.472 6 0.236 4 0.157 7 0.276 3.5 0.138 2 0.079 P.102
FD-G40
22 0.866 11 0.433 8 0.315 12 0.472 6 0.236 4 0.157 7 0.276 3.5 0.138 2 0.079 P.101
FD-G60
46 1.811 23 0.906 15 0.591 24 0.945 12 0.472 8 0.315 20 0.787 10 0.394 7 0.276 P.102
FD-H13-FM2
20 0.787 11 0.433 7 0.276 20 0.787 11 0.433 7 0.276 25 0.984 12 0.472 8 0.315 P.102
FD-H18-L31
– – – – – – – – –
P.102
FD-H20-21
36 1.417 18 0.709 12 0.472 20 0.787 10 0.394 7 0.276 140 5.512 70 2.756 45 1.772 P.102
FD-H20-M1
36 1.417 18 0.709 12 0.472 20 0.787 10 0.394 7 0.276 140 5.512 70 2.756 45 1.772 P.102
Fibers are listed in alphabetic order. Refer to p.5~ “Fiber Selection” for details of each ber.
Notes: 1) The standard sensing objects of the sensing ranges vary depending on the bers.
2) Note that the sensing range of the free-cut type ber may be reduced by 20 % max. depending upon how the ber is cut.
SENSING RANGE OF BLUE LED / GREEN LED / INFRARED LED