Datasheet
Simplied functions for improved operation ease
The FX-500 series and newer models are equipped with only basic functions for improved ease of use. No matter which model you
select, they are all easy to use.
MODE NAVI uses three indicators and a dual display to
show the amplifier’s basic operations. The current operation
mode can be confirmed at a glance, so even a first-time user
can easily operate the amplifier.
Threshold value can be changed
during RUN mode.
Press once
each for object
“present” and
“absent”
The same part number
can be used as either
a main unit or sub unit!
Up to 16 sensors allowed in power-supply wire-saving
CN-71-C□
CN-73-C□
Teaching can be done during
RUN mode.
Disconnection is
possible without
moving the
amplifier sideways
Sub cable
Main cable
Power supply
cable
Output line 1
Output line 2
Output line 16
* Connection of up to 16 units with
FX-500 / FX-400 / DPS-400 / LS-400 is possible.
* The optical communication function can not be used.
MODE NAVI + Direct setting
All FX-500 amplifiers can be used as either a main unit
or a sub unit. Just use a main cable or a sub cable to
distinguish the two. This reduces the costs of inventory
management.
No need to specify a main unit or sub unit
The quick-connection cables enable reduction in wiring.
The connections and man-hours required for the relay
terminal block setup can be reduced and valuable
space is saved.
Wire-saving, space-saving
NAVI display (lights off during RUN mode)
Direct setting
Direct adjustment Direct teaching
L/D
Switches output operation.
L: Light-ON D: Dark-ON
CUST
The sensitivity to received light can be
changed directly.
PRO
Allows the selection of advanced functions
such as timer, shift amount setting and
threshold value tracking setting.
Three times higher emission power and 1.6 times longer
sensing range than conventional models!
Ample sensing distance even with thin ber
* As of January 2016, survey by our company
The sensing range of the thin reective type ber is about 1.6 times longer than that of a conventional product (the sensing range of the
standard reective type ber is about 1.4 times longer). This adds extra exibility to the sensor layout.
Equipped with a mode to minimize the effect of
ambient light
When setting to activate the
environment resistance mode in
the emission frequency setting,
the ambient illuminance for
LED lights becomes about 2.5
times higher than that in the
normal mode. This reduces
erroneous detections caused by
LED lights.
Fiber
Sensing range (STD mode)
Rate of increase
in sensing range
FX-551 FX-501
FT-31
480 mm 18.898 in 315 mm 12.402 in
152 %
FT-42
1,470 mm 57.874 in 1,130 mm 44.488 in
130 %
FD-41
200 mm 7.874 in 125 mm 4.921 in
160 %
FD-61
620 mm 24.409 in 450 mm 17.717 in
138 %
List of functions in PRO mode
PRO 1 Response time setting, timer setting, shift amount setting
PRO 2 Teaching lock setting, digital display item setting, digital display turning setting, Eco setting
PRO 3 Display adjustment setting, reset setting, emission frequency setting, threshold value tracking setting
When the hysteresis is the same, the higher incident
light intensity results in more stable detection.
When the hysteresis is the same, the
higher incident light intensity results in
more stable detection.
Distance
Stable detection!
FX-551
FX-501
Incident light intensity
FD-41
FD-41
STD mode
STD mode
FX-501
FX-551
1.6 times
approx.
longer than conventional models!
Industry's No. 1!
*
Easy adjustment of beam axis
Thanks to the high emission
power, a slight deviation of
beam axis causes no problem.
It is ideal for use in dusty
areas
*
or for detection through
an extremely small slit.
* Need to conrm proper operation in