Spec Sheet

/ Panasonic Ventilation Fan
Description:
Motor/Blower:
• Four–pole totally enclosed condenser ECM
motor rated for continuous use.
• Fan ventilation rates shall be manually
adjustable for 50, 80, or 110 CFM.
• Power Rating shall be 120 volts and 60 Hz.
• Fan shall be UL / cUL listed for tub/shower
enclosure when GFCI protected.
• Motor equipped with thermal cutoff fuse.
• Removable, permanently lubricated, plug-in
motor.
Housing:
• Rust proof epoxy and polyester resin coating,
26 gauge galvanized steel body.
• 4" diameter duct with optional 3" adapter
included.
• Built in backdraft damper.
• Articulating and expandable extension bracket
up to 24".
Grille:
• Attractive design using Poly Pro material.
Attaches directly to housing with torsion springs.
Warranty:
• All Parts: Period of 3 years from the date
of the original purchase.
FV-0511VF1
Panasonic Canada Inc.
5770 Ambler Drive
Mississauga, ON
L4W 2T3
business.panasonic.ca/ventilation
IAQ21021ST -r4
For complete Installation Instructions visit business.panasonic.ca/ventilation
Model Quantity Comments Project:
Location:
Architect:
Engineer:
Contractor:
Submitted by:
Date:
FV-0511VF1
3" or 4" Duct
Ceiling Radiation Damper:
• WhisperFit
TM
DC is UL / cUL listed for use with
the Panasonic Ceiling Radiation Damper
(Model #: PC - RD05C5, sold separately).
Customizable Ventilation fan shall be ceiling mount,
ENERGY STAR
®
certified with built-in speed
selector. Select from 50/80/110 CFM with
<0.3/<0.3/0.8 sone as certified by the Home
Ventilating Institute (HVI) at 0.1 w.g. with 50/80/110
CFM and no more than 0.4/0.8/1.2 sones at 0.25
w.g. and 50/84/109 CFM at 0.375 w.g. Power
Consumption shall be no greater than 4.0/5.9/10.2
watts at 0.1 w.g. and 7.1/9.4/14.6 watts at 0.25
w.g. and 10.0/13.2/17.9 watts at 0.375 w.g.
ENERGY STAR
®
certified with efficiency of no less
than 13.5/13.9/11.0 CFM/watt at 0.1 w.g. and
7.6/8.7/7.7 CFM/watt at 0.25 w.g. and 5.4/6.5/6.2
CFM/watt at 0.375 w.g. Duct diameter shall be no
less than 4" (3" if using the included duct adapter).
The motor shall be enclosed with brushless ECM
motor engineered to run continuously. Power rating
shall be 120v/60Hz. Housing material shall be no
less than 26-gauge galvanized steel with rust proof
epoxy and polyester resin coating. Fan shall be
UL / cUL listed for tub/shower enclosure when
GFCI protected. Fan can be used to comply with
ASHRAE 62.2, LEED, ENERGY STAR
®
IAP, Earth
Craft, and California Title 24.
• ECM Motor with SmartFlow Technology
䢢䢷䢯䢷䢱䢺䢤䢢
䢢䢶䢤䢢
䢢䢵䢤䢢
䢢䢳䢲䢯䢳䢱䢶䢤䢢
䢢䢳䢲䢯䢳䢱䢶䢤䢢
䢢䢳䢵䢤䢢
䢢䢳䢵䢤䢢
䣈䣘䢯䢲䢷䢳䢳䣘䣈䢳
Ventilating fan shall be low sone ceiling mount
rated for continuous operation. Fan shall be
ENERGY STAR
®
certified by the Home
Ventilating Institute (HVI). Evaluated by the
Underwriters Laboratories and conform to
UL / cUL standards.
Specifications: WhisperFit
TM
DC FV-0511VF1
4" Duct 4" Duct 4” Duct 3" Duct 3" Duct 3” Duct
Ventilation Fan
Characteristics
Static Pressure in inches w.g. 0.1 0.25 0.375 0.1 0.25 0.375 0.1 0.25 0.375 0.1 0.25 0.375 0.1 0.25 0.375 0.1 0.25 0.375
Air Volume (CFM) 110 111 109 80 80 84 50 50 50 110 94 69 80 81 67 50 51 55
Noise (sones) 0.8 1.2 - 0.3 0.8 - <0.3 0.4 - 2.0 1.5 - 0.8 1.4 - <0.3 0.9 -
Power Consumption (Watts)
Energy Efciency (CFM/Watt)
10.2 14.6 17.9 5.9 9.4 13.2 4.0 7.1 10.0 17.1 16.4 13.6 8.8 13.0 13.5 4.6 7.7 10.8
11.0 7.7 6.2 13.9 8.7 6.5 13.5 7.6 5.4 6.6 5.9 5.2 9.4 6.5 5.2 11.5 7.0 5.3
Speed (RPM) 977 1222 1392 820 1142 1349 795 1152 1374 1341 1429 1476 1094 1357 1476 870 1205 1426
Current (amps) 0.18 0.24 0.28 0.11 0.16 0.22 0.08 0.13 0.17 0.27 0.26 0.22 0.15 0.21 0.22 0.09 0.14 0.18
MAX. Current (amps) 0.29
Power Rating (V/Hz) 120/60
YesENERGY STAR Qualied
(HVI-Certied Data)
TM