Full Product Manual

Rust-proof paint treatment on galvanized housing
Thermal fuse protection
Meets Washington State Ventilation and Indoor Air Quality
code and ASHRAE 62.2 - 2010
3 Year Warranty
PRODUCT
Exchange
Capillary Core
Supply Air Filter
Exhaust Air
Filter
N/A=not applicable
w.g.=water gauge
S.P.=static pressure
Specifications
FV-04VE1
40 CFM 20 CFM 10 CFM
Characteristics
Static pressure in inches w. g. 0.1 0.1 0.1
Air Volume Exhaust (CFM) 40 20 10
Air Volume Supply (CFM) 30 20 10
Noise (sones) 0.8 <0.3 N/A
Power Consumption (Watts) 23 21 17
Speed 1479 1292 1095
Current 0.15 0.10 0.09
Power Rating (V/Hz) 120/60
Specifications
Motor Type Condenser
Type of Motor Bearing Ball
Thermal Fuse Protection Yes
Blower Wheel Type 2 x Sirocco
Apparent Sensible
Effectiveness
Heating (%) 32 °F (0°C) 66% at 30 CFM
Total Recovery
Efficiency
Cooling (%) 95 °F (35°C) 36% at 29 CFM
Note: CFM and sones are tested in accordance with HVI
testing standards. Energy efficiency is tested in accordance
with CSA-C439 standard.
22-1/2 in.
5 in.
10-3/4 in.
3-3/8 in.
5-9/16 in.
8-5/8 in.
8-1/2 in.
4-1/2 in.
2 x 4" ducts
FV-04VE1
Optional Exterior Wall Cap Optional Elbow
FV-WC04VE1 FV-EB04VE1
0.00
0.10
0.20
0.30
0.40
0.50
0102030405060
Airflow(CFM)
20 Feet
40 Feet
60 Feet
80 Feet
100 Feet
FV-04VE1
(Exhaust)
FV-04VE1
(Supply)
Static Pressure (inch w.g.)
FV-04VE1 40/20 CFM or 20/10 CFM Two 4" ducts
IAQ22127SSDesign and specifications subject to change without notice.
Panasonic
IAQ Division
Two Riverfront Plaza
Newark, NJ 07102
na.panasonic.com/us/iaq
For Order Information
PHONE: 866-292-7299
FAX: 888-553-0723
ventfans@us.panasonic.com
Filters
WhisperComfort has two air filters. One filter is located on the inside
louver of the grille. The second filter is located in the unit held by a
bracket with a handle. Pull the handle to remove the filter bracket and
remove the filter from the bracket. Both filters should be
vacuumed with a soft brush attachment.