Specification Sheet
/ Panasonic Recessed Inlet
Description:
Multi-purpose exhaust or supply recessed inlet
for use with remote mount in-line fans and
HERVs; or as a light only option matching the
WhisperRecessed LED™ fan/light. Recessed inlet
Ventilating Institute (HVI). Recessed inlet shall
by Underwriters Laboratories and conform to both
UL and cUL safety standards.
Housing:
• Rust proof epoxy and polyester resin coating,
26 gauge galvanized steel body.
• Integrated dual 4" or 6” diameter duct adapter.
helps provide an Air Barrier and assists with the
decrease in leakage in the Building Envelope
during blower door testing.
• Built in backdraft damper.
• Expandable extension bracket up to 24".
• Double hanger bar system allowing for ideal
positioning.
Trim Ring:
• Attractive design using Poly Pro material.
• Attaches directly to housing with torsion springs.
FV-NLF46RES
Panasonic Life Solutions Company of America
IAQ Divsion
Two Riverfront Plaza
Newark, NJ 07102
us.panasonic.com/ventfans
Recessed Inlet FV-NLF46RES 4" or 6" Duct
Power Rating (V/Hz) 120/60
For complete Installation Instructions visit us.panasonic.com/ventfans
Model Quantity Comments Project:
Location:
Architect:
Engineer:
Contractor:
Submitted by:
Date:
FV-NLF46RES
4" or 6" duct
FV-NLF46RES
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0 20 40 60 80 100 120 140
Static Pressure (inch w.g.)
Airflow (CFM)
FV-NLF46RES
Resistance Curve 4" or 6" duct
IAQ20016ST-r3
Light (Included):
• Includes (1) replaceable, 8W ENERGY STAR 2.0
certied, GU24 base LED lamp, JA-8 compliant
for CA Title 24 and Title 20
• 2700 Kelvin Warm White/>92 CRI/720 lumens/
90 LPW/25,000 hour rated average life.
• LED lamp is dimmable.
• FCC Part 15 compliant.
Warranty:
• ALL Parts: 3 Years from original purchase date.
LED: 5 years from original purchase date.
Architectural Specications:
Exhaust or supply recessed inlet shall be ceiling
mount. Inlet housing collar opening shall be no less
than 6" round, with a trim outer diameter of no less
than 7-1/4" round. Power rating shall be
120v/60Hz. Duct diameter shall be no less than 4",
inclusive of an integrated dual 4" or 6" duct adapter.
Inlet shall be UL and cUL listed for tub/shower
enclosure when GFCI protected. Inlet housing shall
be Type IC. Inlet can be used to comply with
California Title-24. Lamp shall be of the LED type
and beno less than (1) 8W, ENERGY STAR 2.0
certied,GU24base LED lamp, JA-8 compliant for
CA Title 24 and Title 20. LED lamp maintains
25,000 hours rated average life.
(1) 8 Watt GU24 base LED lamp, /2700 Kelvin
Warm White/>92CRI/720 lumens/90 LPW/
ENERGY STAR 2.0 certied, JA-8 compliant
for CA Title 24 and Title 20, 25,000 rated
average life.
Dimmer Switch Compatibility
Brand Series Model Load(LED) Dimmability
Lutron
Skylark CTCL-153P 150 OK
Toggler TGCL-153P 150 OK
Diva DVCL-153P 150 OK
Maestro MACL-153M 150 OK
Ariadni AYCL-153P 150 OK
Leviton SureSlide 6674 150 OK