Sell Sheet
4" or 6" duct
Specification Submittal Data / Panasonic Ventilation Fan
Description
Ventilating fan shall be low noise ceiling mount
type rated for continuous operation. Fan shall
be ENERGY STAR rated and certified by the
Home Ventilating Institute (HVI). Evaluated by the
Underwriters Laboratories and conform to both
UL and cUL standards.
Motor/Blower:
• Four–pole totally enclosed condenser motor
rated for continuous use.
• Power rating shall be 120 volts and 60 Hz.
• Fan shall be UL and cUL listed for tub/shower
enclosure when used with a GFCI branch circuit
wiring.
• Motor equipped with thermal–cutoff fuse.
• Permanently lubricated plug-in motor.
Housing:
• Rust proof paint, galvanized steel body.
• Detachable dual 4" or 6" diameter duct adaptor.
• Built in backdraft damper.
• Expandable extension bracket up to 24".
• Double hanger bar system allowing for ideal
positioning.
Grille:
• Attractive design using PP material.
• Attaches directly to housing with torsion
springs.
Warranty:
• 3-Year limited warranty.
Architectural Specifications:
Ventilation fan shall be ceiling mount, ENERGY
STAR rated, with no less than 110 CFM and
no more than 0.3 sone at 0.1 static pressure in
inches water gauge (w.g.) and no less than 91
CFM, and no more than 0.5 sone as certied
by HVI at 0.25" w.g. Power consumption shall
be no greater than 24.3 watts at 0.1" w.g. and
24.2 watts at 0.25" w.g. ENERGY STAR rated
with efciency of no less than 4.6 CFM/Watt
at 0.1" w.g. and 3.9 CFM/Watt at 0.25" w.g.
The motor shall be totally enclosed, four pole
condenser type engineered to run continuously.
Power rating shall be 120v/60Hz. Included is a
detachable dual 4" or 6" diameter duct adaptor.
Dual motion and humidity sensors with adjustable
delay off timer that can be set from 30 seconds
to 60 minutes. Humidity sensor is the rapid rise
in relative humidity (RH) type with user-adjusted
set points between ~30% to ~80% RH. Fan shall
be UL and cUL listed for tub/shower enclosure
when used with GFCI branch circuit wiring. Fan
shall be ASHRAE 62.2, LEED, ENERGY STAR
IAP, EarthCraft, California Title-24, WA Ventilation
Code and CALGreen compliant.
FV-11VQC5
Panasonic Home and Environment Company
Division of Panasonic Corporation of North America
One Panasonic Way
Secaucus, NJ 07094
www.panasonic.com/building
Specifications: WhisperSense FV-11VQC5
4" or 6" Duct
(Standard)
Ventilation Fan
Characteristics
(HVI tested data)
Static Pressure in inches w.g. 0.1 0.25
Air Volume (CFM) 110 91
Noise (sones) 0.3 0.5
Power Consumption (watts) 24.3 24.2
Energy Efciency (CFM/Watt) 4.6 3.9
Speed (RPM) 957 1170
Current (amps) 0.22 0.21
Power Rating (V/Hz) 120/60
ENERGY STAR Qualied YES
For complete Installation Instructions visit www.panasonic.com/building
Model Quantity Comments Project:
Location:
Architect:
Engineer:
Contractor:
Submitted by:
Date:
FV-11VQC5