Specification Sheet
Supply hood
should include
a bird screen
with backdraft
damper removed
Exhaust
hood should
include a
backdraft
damper
ALTERNATIVE PANASONIC SOLUTION
EXHAUST
SUPPLY
INSTALLATION
Mounting: Intelli-Balance 100 can easily be mounted in the ceiling or on a wall
using the included cleat hanger bar. It measures 23" wide and fits between joists
16" on center. Adjustable brackets and screws are provided to secure the unit
to the joist on 4 corners. Intelli-Balance 100 can also be chain mounted and
suspended. It is recommended that you use 4 chains, 20-24" in length with a
weight capacity of +66 pounds.
Wiring: Power consumption is 64 Watts on FV-10VEC1 and 62 Watts on FV-10VE1,
with a power rating of 120/60 V/Hz.
Duct: Insulated 4"or 6" duct is recommended.
Static Pressure Access Ports: The unit’s access panel incorporates static
pressure ports for measuring the differential pressure of fresh air and exhaust
air so the dampers can be adjusted for balancing airflows.
Optional Accessories (Sold Separately):
FV-FL0810VE1: MERV 8 Replacement Filter
FV-FV1310VE1: MERV 13 Optional Replacement Filter
FV-WC04VE1: Optional Exterior Wall Cap
FV-WC04VE1*
Intelli-Balance 100
FV-10VEC1 FV-10VE1
Characteristics COLD CLIMATE TEMPERATE CLIMATE
Static pressure in inches w.g. 0.1 0.4 0.1 0.4
Net Exhaust Air Volume (CFM) 96 95 95 95
Net Supply Air Volume (CFM) 98 96 99.0 101
Power Consumption (Watts) 64.0 84.0 62.0 80.0
Power Rating (V/Hz) 120/60 120/60
Supply Temperature Net Air Flow
Power
Consumed
(Watts)
Sensible Apparent Net
Recovery Sensible Moisture
°C °F L/S CFM Efficiency Effectiveness Transfer
Heating
0 32 25 53 24 81 88 0.8
0 32 31 67 34 77 86 0.76
0 32 40 86 54 75 83 0.72
-25 -13 27 57 66 65 85 0.7
-25 -13 32 68 84 64 80 0.7
Cooling
Total Recovery Efficiency
35 95 23 48 16 65
FV-10VEC1
Supply Temperature Net Air Flow
Power
Consumed
(Watts)
Sensible Apparent Net
Recovery Sensible Moisture
°C °F L/S CFM Efficiency Effectiveness Transfer
Heating
0 32 25 54 20 79 90 0.76
0 32 32 67 28 79 88 0.76
0 32 41 87 46 75 85 0.72
-25 -13 - - - - - -
-25 -13 - - - - - -
Cooling
Total Recovery Efficiency
35 95 25 52 22 73
FV-10VE1
FV-10VEC1 50-80-100 CFM 4 x 4" or 6" Ducts FV-10VE1 50-80-100 CFM 4 x 4" or 6" Ducts
Static Pressure (inch w.g.)
Airflow (CFM)
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1
0
0 20 40 60 80 100 120
Net Supply Air
Net Exhaust Air
Static Pressure (inch w.g.)
Airflow (CFM)
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1
0
0 20 40 60 80 100 120
Net Supply Air
Net Exhaust Air
VF16547SSDesign and specifications subject to change without notice.
Panasonic Eco Solutions of North America
Eco Products Division
Two Riverfront Plaza
Newark, NJ 07102
us.panasonic.com/ventfans
For Order Information
PHONE: 866-292-7299
FAX: 888-553-0723
ventfans@us.panasonic.com
TYPICAL WALL CAP INSTALLATION
*FV-WC04VE1 is ideal for use in smaller, multi-family applications.
It is not recommended for use at CFM settings higher than 50 CFM.
28-1/2
'’
8-7/8'’
23'’
4' ’ Di a
6' ’ Di a
6' ’ Di a
4' ’ Di a
13'’
FV-10VEC1/FV-10VE1