Engineering Bulletin
ARCHITECTURAL SPECIFICATIONS 
PANASONIC ADVANCED VENTILATION SOLUTIONS 
FV-0511VQ1 WhisperCeiling® DC™ – 50-80-110 CFM Fan, Ceiling Mount, Single Speed 
Ventilation fan shall be UL and cUL listed for ceiling mount and tub/shower enclosure when 
GFCI protected. Fan shall also be ENERGY STAR® certified, with a built-in speed selector. 
Choose from 50-80-110 CFM and no more than <0.3/<0.3/<0.3 sone as certified by the Home Ventilating 
Institute (HVI) at 0.1 static pressure in inches water gauge (w.g.) with no less than 53-83-111 CFM and no 
more than 0.4/0.6/0.9 sone as certified by HVI at 0.25 w.g. Power Consumption shall be no greater than 
4.0/5.9/10.6 watts at 0.1 w.g. and 7.2/10.8/16.4 watts at 0.25 w.g., with efficiency of no less than 2.5/13.6/10.6 
CFM/watt at 0.1 w.g. and 7.4/7.7/6.9 CFM/watt at 0.25 w.g. The motor shall be totally enclosed with a 
brushless ECM motor engineered to run continuously. ECM motor speed shall automatically increase when the 
fan senses static pressure to maintain selected CFM. Power rating shall be 120V/60Hz. Duct diameter shall be 
no less than 4", inclusive of an integrated dual 4" or 6" duct adapter. Fan can be used to comply with ASHRAE 
62.2, LEED, ENERGY STAR IAP, EarthCraft, CA Title 24 and WA state code. 