Datasheet
Thermal Cutoffs (TCO)
Design and specifi cations are each subject to change without notice. Ask factory for the current technical specifi cations before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately.
✽
1 Rated Functioning Temperature (Tf)
The temperature at which a TCO changes its state of conductivity to open circuit with loading detection current only.
Tolerance;
PS
E
; ±7 °C
UL,CSA,VDE, BEAB, CCC;
–10
°C
✽
2 Functioning Temperature (Fusing-off temperature)
The functioning temperature at which a TCO changes its state of conductivity to open circuit in the ambient air oven which increases
temperature by 1 °C per minute and with loading the detective current 0.1 A or less.
✽
3 Maximum Operating Temperature.
The maximum temperature at which a TCO can be maintained while conducting rated current for 1000 h.
For details please refer to specifi cation.
✽
4 Holding Temperature (Th)
The maximum temperature at which a TCO can be maintained while conducting rated current for 168 h which will not cause a change in
state of conductivity to open circuit.
✽
5 Maximum Temperature Limit (Tm)
The maximum temperature at which a TCO can maintains its mechanical and electrical properties with out closing again for 10
minutes after a TCO has changed its state of conductivity.
0
● MU series
Note: (1) The information of the Approved Safety Standards is furnished as of Jun. 2010.
Approved Safety Standards File No. UL:E60271
● MP series
Note: (1) The information of the Approved Safety Standards is furnished as of Jun. 2010.
Approved Safety Standards File No. UL:E60271
Part No.
Rated
Functioning
Temp. : Tf
✽
1
(°C)
Functioning
Temp.
✽
2
(°C)
Electrical Rating
Maximum
Operating
Temp.
✽
3
(°C)
Holding
Temp. : Th
✽
4
(°C)
Maximum
Temp.
Limit : Tm
✽
5
(°C)
Approved
Safety
Standards
AC/
DC
Volt.
(V)
Amp.
(A)
UL
EYP2MP092AFT
92 88
+3
DC 32 2 55 60 135
EYP2MP098AFT
98 94
+3
DC 32 2 60 65 135
–4
–2.5
Part No.
Rated
Functioning
Temp. : Tf
✽
1
(°C)
Functioning
Temp.
✽
2
(°C)
Electrical Rating
Maximum
Operating
Temp.
✽
3
(°C)
Holding
Temp. : Th
✽
4
(°C)
Maximum
Temp.
Limit : Tm
✽
5
(°C)
Approved
Safety
Standards
AC/
DC
Volt.
(V)
Amp.
(A)
UL
EYP4MU092GFD
92 89
+3
DC 32 4 55 55 135
–4
Sep. 2010