Datasheet
– 382 –
Thermal Cutoffs (TCO)
Design and specifi cations are each subject to change without notice. Ask factory for the current technical specifi cations before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately.
Note: (1) For long lead types add the letter “L” at the end op the part number.
(2) The information of the Approved Safety Standards is furnished as of Jun. 2010.
Approved Safety Standards File No. UL:E60271, CSA:1687496(LR67163), VDE:481106-1171-0001, BEAB:C1144, CCC:2002010205004249
● F series
■ Ratings
● N series
Part No.
Type No. of
Approved
Standards
Rated
Functioning
Temp. : Tf
✽
1
(°C)
Functioning
Temp.
✽
2
(°C)
Electrical Rating Maximum
Operating
Temp.
✽
3
(°C)
Holding
Temp. : Th
✽
4
(°C)
Maximum
Temp.
Limit : Tm
✽
5
(°C)
Approved Safety
Standards
AC/
DC
Volt.
(V)
Amp.
(A)
PS
E
UL CSA VDE BEAB CCC
EYP2BN082
N082 86 82±2
AC 250 2 60 60
200
AC 125 3 52 56 —
—
DC 50 4 45 50 —
—
EYP2BN099
N099 102 98
+4
AC 250 2 65 75
200
AC 125 3 60 70 —
—
DC 50 4 55 65 —
—
EYP2BN109
N109 114 110 ± 3
AC 250 2 80 90
200
AC 125 3 76 86 —
—
DC 50 5 65 74 —
—
EYP2BN110
N110 115 110
+3
AC 250 2 80 90
200
AC 125 3 76 86 —
—
DC 50 5 65 74 —
—
EYP2BN127
N127 134 129±4
AC 250 2 90 100
200
AC 125 3 75 90 —
—
DC 50 4 65 80 —
—
EYP2BN134
N134 139 135±3
AC 250 2 100 110
200
AC 125 3 85 100 —
—
DC 50 6 60 70 —
—
EYP2BN143
N143 145 141±2
AC 250 2 110 120
200
AC 125 3 105 115 —
—
DC 50 6 80 90 —
—
–2
–3
Note: (1) For long lead types add the letter “L” at the end op the part number.
(2) The information of the Approved Safety Standards is furnished as of Jun. 2010.
Approved Safety Standards File No. UL/C-UL:E60271, CSA:1709436(LR67163), VDE:481106-1171-0003, BEAB:C1133, CCC:2002010205004248
Part No.
Type No. of
Approved
Standards
Rated
Functioning
Temp. : Tf
✽
1
(°C)
Functioning
Temp.
✽
2
(°C)
Electrical Rating Maximum
Operating
Temp.
✽
3
(°C)
Holding
Temp. : Th
✽
4
(°C)
Maximum
Temp.
Limit : Tm
✽
5
(°C)
Approved Safety
Standards
AC/
DC
Volt.
(V)
Amp.
(A)
PS
E
UL
C-UL
CSA VDE BEAB CCC
EYP1BF101
F101 102 98±3
AC 250 1 65 75
200
AC 125 2 60 70 —
—
DC 50 3.5 55 65 —
—
EYP1BF115
F115 115 110
+3
AC 250 1 80 90
200
AC 125 2 76 90 —
—
DC 50 4 70 80 —
—
EYP1BF134
F134 134 129
+4
AC 250 1 90 105
200
AC 125 2 85 100 —
—
DC 50 4 65 80 —
—
EYP1BF138
F138 139 135±3
AC 250 1 100 110
200
AC 125 2 90 105 —
—
DC 50 5 65 70 —
—
EYP1BF145
F145 145 141±2
AC 250 1 110 125
200
AC 125 2 110 125 —
—
DC 50 5 80 95 —
—
–3
–2
Sep. 201000