Datasheet

SENSORS FOR
SEMICONDUCTOR INDUSTRY
EX-F1
FD-F4/F9
FD-F8YFT-Z8Y
Other
Products
Liquid Leak / Liquid Level Sensing
Chemical-resistant
Outer dia."6 to "13 mm
"0.236 to "0.512 in
PFA (Fluorine resin) or
equivalently transparent
pipe, wall thickness 1 mm
0.039 in
(Note 2)







Liquid (Note 1)
EX-F1
EX-F1-C5
APPLICATIONS
The beam passes through
the wall into the liquid.
<Empty pipe><Filled pipe>
The beam reflected from
the inner surface of the
pipe wall returns to the
beam-receiving part.
609
EX-F1
Detecting liquid level in a tank
ORDER GUIDE
Notes: 1) Unclear or highly viscous liquid may not be detected stably.
2) Do not use the sensor with pipes other than the above specified.
Appearance Sensing object Applicable pipe diameter Model No.Type
Amplifier Built-in
Pipe-mountable
5 m 16.404 ft
cable length type
Principle of Detection
When the pipe is empty, the beam is reflected from the
inner surface of the pipe wall and returns to the beam-
receiving part, since the difference in the refractive
indexes of the pipe and air is large.
When there is liquid in the pipe, the beam enters the
liquid through the wall and does not return to the beam-
receiving part, since the difference in the refractive
indexes of the pipe and the liquid is small.
05/2010