Datasheet

SPECIFICATIONS
Type
Compact fan type
Item
Model No.
ER-Q
Charge removal time
1.5 sec. approx. (Note)
Ion balance ±10 V or less (Note)
Power supply voltage
24 V DC ± 10%
Power consumption
200 mA or less
Discharge method
High-frequency AC method
Discharge output voltage
±2 kV approx.
Max. fan speed 6.4 m/s (Note)
Max. fan volume 0.2 m
3
/min
Main functions
Discharge check, Discharge error, Fan error,
Check output, Error output
Indicators Discharge (DSC): Green LED, Alarm (ALARM): Red LED
Ozone generation amount
0.02 ppm or less (Note)
Ambient temperature
0 to +50 °C +32 to +122 °F (No dew condensation)
Storage: -10 to +65 °C +14 to +149 °F
Ambient humidity
35 to 65% RH (No dew condensation) / Storage: 35 to 65% RH
Vibration resistance
10 to 150 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z
directions for two hours each
Grounding method
C (capacitor) grounding
Material Enclosure: PBT, Discharge needle: Tungsten
Weight Main unit: 110 g approx.
Accessories
Connector for wiring: 1 set
[Manufactured by MOLEX: Housing (5557-08P), Terminal (5556T)]
Note: Typical value at 100 mm 3.937 in from directly in front of air outlet, fan speed MAX, with no lter
installed.
OPTIONS
ER-QMS1/ Mounting bracket
The ER-Q mounting bracket. Adjust the air output direction.
ER-QCC2/ Connector-attached cable
Length 2 m 6.562 ft
ER-QCC5/ Connector-attached cable
Length 5 m 16.404 ft
0.13 mm
2
8-core
connector cabtyre cable
Cable outer diameter:
ø3.7 mm
ø0.146 in
ER-VAPS1/ AC adapter
• IN: 100 to 240 V AC, 50 / 60 Hz, 40 VA
• OUT: 24 V DC, 750 mA
Ambient temperature: 0 to +40 °C
+32 to +104 °F
ER-QFX5/ Air lter
Fan intake lter (5 pcs. per set)
ER-QANT/ Discharge needle unit
Unit with tungsten needles (1 pc.)
PRECAUTIONS FOR PROPER USE
This product does not possess control functions
for safety assurance such as accident prevention.
This product has been developed / produced for
industrial use.
Do not use this product in places where there
may be a danger of flammable or combustible
items being present.
DIMENSIONS (Unit: mm in)
CHARGE REMOVAL CHARACTERISTICS (TYPICAL)
Measured using a 150 mm 5.906 in CPM (charge
plate monitor) (At center of CPM)
Filter cover
Alarm indicator (red)
Discharge indicator
(green)
Power switch
2-M3 screws (depth 10 0.394) (Note)
Ion air outlet
Connector 5559-08
manufactured by MOLEX
Fan speed control
2-ø3.5 ø1.378
mounting hole
Discharge needle unit
ø
3.7
ø
0.146 cable 0.5 m 1.64 ft
3.5
0.138
3.5
0.138
5.5
0.217
52
2.047
25.4
1.000
29
1.142
33
1.299
65
2.559
58
2.283
19.8
0.780
60
2.362
0
0
100
3.937
200
7.874
300
11.811
400
15.748
500
19.685
-200
-7.874
-150
-5.906
-100
-3.937
-50
-1.969
0
0
50
1.969
100
3.937
150
5.906
200
7.874
Charge removal width W (mm in)
Charge removal distance L (mm in)
2 sec
5 sec
10 sec
CPM
L
W
0
0
100
3.937
200
7.874
300
11.811
400
15.748
500
19.685
-200
-7.874
-150
-5.906
-100
-3.937
-50
-1.969
0
0
50
1.969
100
3.937
150
5.906
200
7.874
Charge removal field (vertical direction) (Fan speed MAX, filter is mounted)
Charge removal distance L (mm in)
2 sec
5 sec
10 sec
CPM
L
W
Charge removal field (horizontal direction) (Fan speed MAX, filter is mounted)
Charge removal width W (mm in)
Note: Screw threads exclusive for
mounting brackels. Do not
use them in mounting with
other products.
When mounting this product
directly to a case or such, fix
it with M3 screws using
2-ø3.5
ø1.378 mounting
holes.
No. LCE-ERQ-3 March, 2010
2431-1 Ushiyama-cho, Kasugai-shi, Aichi,
486-0901, Japan
Phone: +81-568-33-7211
FAX: +81-568-33-2631
SUNX Limited
Phone: +81-568-33-7861
FAX: +81-568-33-8591
Overseas Sales Division
http://www.sunx.com
All information is subject to change without prior notice.