Datasheet
Adjustable Range Reective Photoelectric Sensor EQ-500 SERIES
370
Selection
Guide
Amplier
Built-in
Power Supply
Built-in
Amplier-
separated
CX-400
CY-100
EX-10
EX-20
EX-30
EX-40
CX-440
EQ-30
EQ-500
MQ-W
RX-LS200
RX
RT-610
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
PRECAUTIONS FOR PROPER USE
Stability indicatorTimer function (EQ-5□T only)
• Since the EQ-500 series uses a 2-segment photodiode
as its receiving element, and sensing is done based
on the difference in the incident beam angle of the
reected beam from the sensing object, the output and
the operation indicator (orange) operate according to
the object distance.
Furthermore, the stability indicator (green) shows the
margin of the setting distance.
• EQ-5□T incorporates an OFF-delay timer, which is
useful when the response of the connected device is
slow, etc., and an ON-delay timer, which is useful for
detecting objects that move slowly, for example.
• The OFF-delay and ON-delay timers can be used
simultaneously.
• For DC-voltage type, set the DIP switch for the timer
mode to ‘Timer ON’ side.
Unstable
operating condition
Setting distance
Output (Operation indicator)
(In case of Detection-ON)
Stability indicator
Stable operating
condition
Stable operating
condition
Sensing object
ON (Lights up)
OFF (Lights off)
Lights up
Lights off
Others
• Do not use during the initial transient time (50 ms) after
the power supply is switched on.
• Its distance adjuster is mechanically operated. Do not
drop; avoid other shocks.
DIMENSIONS (Unit: mm in)
The CAD data in the dimensions can be downloaded from our website.
EQ-501(T) EQ-502(T) EQ-511(T) EQ-512(T)
Sensor
26
1.024
68
2.677
68
2.677
2
0.079
58
2.283
22
0.866
30
1.181
58
2.283
5
0.197
5
0.197
OFF-delay timer adjuster (Note 2)
ON-delay timer adjuster (Note 2)
Stability indicator (Green)
Operation mode switch (Note 1)
Distance adjuster (2-turn)
Adjuster indicator
Operation indicator (Orange)
Beam-
receiving part
Center of beam-
emitting
(Center of sensing)
3-M5 nut seats
(on both sides)
3-ø5.1 ø0.201
mounting holes
Notes: 1) The operation mode switch of the DC-voltage type is the DIP
switch.
2) For EQ-5□T only.
Assembly dimensions with sensor mounting bracket
MS-EQ5-01 (Optional) (Foot angled mounting)
6.5
0.256
58
2.283
58
2.283
5
0.197
Center of beam-
emitting
(Center of sensing)
2-M5 (length 30 1.181) screws
t 2
t 0.079
4
0.157
(10)
(0.394)
(10)
(0.394)
37
1.457
26
1.024
78
3.071
18
0.709
88
3.465
58
2.283
29
1.142
29
1.142
6.5
0.256
ø6.5
ø0.256
17.5
0.689
(30.5)
(1.201)
Material: Cold rolled carbon steel (SPCC)
Two M5 (length 30 mm 1.181 in) screws with washers and two nuts are attached.
Refer to p.1458~ for general precautions.
Time chart
Timer period: T = 0.1 to 5 sec. (variable)
Sensing
condition
Operation
Detection
normal operation
Detection ON-delay
Detection OFF-delay
Detection ON / OFF-delay
Non-detection
normal operation
Non-detection ON-delay
Non-detection OFF-delay
Non-detection
ON / OFF-delay
ON
OFF
ON
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
OFF
ON
OFF
T
T
T T T
T
T T T
TT
T
Detection
Non-
detection