Datasheet

Adjustable Range Reective Photoelectric Sensor EQ-500 SERIES
368
Selection
Guide
Amplier
Built-in
Power Supply
Built-in
Amplier-
separated
CX-400
CY-100
EX-10
EX-20
EX-30
EX-40
CX-440
EQ-30
EQ-500
MQ-W
RX-LS200
RX
RT-610
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
SENSING CHARACTERISTICS (TYPICAL)
EQ-502 (T) EQ-512 (T)
Sensing elds
Correlation between material
(200 × 200 mm 7.874 × 7.874 in) and sensing range
Setting distance: 0.5 m 1.640 ft Setting distance: 1 m 3.281 ft
0
0.5
1.640
1
3.281
These bars indicate
the sensing range with
the respective objects
when the distance
adjuster is set to a
sensing range of 1 m
3.281 ft / 0.5 m 1.640 ft
long, respectively, with
white non-glossy
paper.
•••
•••
Sensing range L (m ft)
1 m
3.281 ft
0.5 m
1.640 ft
White non-
glossy paper
Cardboard
Plywood
Black rubber
Gray non-grossy
paper (Lightness: 5)
0
0
0.2
0.656
0.4
1.312
0.6
1.969
0.8
2.625
L
Gray non-glossy paper
Lightness: 5
20
0.787
10
0.394
10
0.394
20
0.787
200 × 200 mm
7.874 × 7.874 in
Non-glossy paper
Sensor
White non-
glossy paper
Left
Right
Center
Operating point ℓ (mm in)
Setting distance L (m ft)
20 1001
02
0
0
0.5
1.640
1
3.281
L
Sensor
Gray non-glossy paper
Lightness: 5
020
0.787
10
0.394
10
0.394
20
0.787
200 × 200 mm
7.874 × 7.874 in
Non-glossy paper
White non-
glossy paper
Left
Right
Center
Operating point ℓ (mm in)
Setting distance L (m ft)
Correlation between color (200 × 200 mm 7.874 × 7.874 in non-glossy paper) and sensing range
Emitted beam
Correlation between sensing object size and sensing range
These bars indicate
the sensing range with
the respective colors
when the distance
adjuster is set to a
sensing range of 1 m
3.281 ft / 0.5 m 1.640 ft
long, respectively, with
white non-glossy
paper.
The sensing range
also varies depending
on material.
0.5
1.640
1
3.281
•••
•••
Sensing range L (m ft)
White
Yellow
Orange
Red
Brown
Blue
Green
Gray
(Lightness: 8)
Gray
(Lightness: 5)
1 m
3.281 ft
0.5 m
1.640 ft
0
1
3.281
0.5
1.640
Distance L (m ft)
ø26 mm
ø1.024 in
ø20 mm
ø0.787 in
This curve shows the
characteristics with
the maximum
sensing range set to
1 m 3.281 ft, with
white non-glossy
paper
(200 × 200 mm
7.874 × 7.874 in).
0.5
1.640
1
3.281
White non-
glossy paper
Sensor
L
White non-glossy paper
side length a (mm in)
Sensing range L (m ft)
0 50
1.969
100
3.937
150
5.906
200
7.874
Setting distance: 1 m 3.281 ft
PRECAUTIONS FOR PROPER USE
Refer to p.1458~ for general precautions.
M5 nut
M5 (length 30 mm 1.181 in)
screw with washers
Sensor
mounting
blacket
MS-EQ5-01
(Optional)
Mounting
The tightening torque
should be 0.8 N·m or less.
Care must be taken
regarding the sensor
mounting direction with
respect to the object’s
direction of movement.
Sensing object Sensing object
Do not make the sensor
detect an object in this
direction because it may
cause unstable operation.
Sensing object
When detecting a specular object (aluminum or copper foil,
etc.) or an object having a glossy surface or coating, please
note that there are cases when the object may not be detected
due to a change in angle, wrinkles on the object surface, etc.
If a specular body is present in the background, faulty operation may
be caused due to a small change in the angle of the background
body. In that case, install the sensor at an inclination and conrm the
operation with the actual sensing object.
When a specular body is present below the sensor, use the
sensor by tilting it slightly upwards to avoid faulty operation.
Specular
face
Specular
face
Tilt
This product is not easily affected by the reected light
intensity since this sensor is the adjustable range reective
type. When the reected light intensity is remarkably low,
the sensing range may be affected. In that case, mount the
sensor, while checking light-up of the stable indicator (green).
The mounting screws of the terminal cover and display cover
should certainly be tightened to maintain water-resistance;
the tightening torque of the screws should be 0.3 to 0.5 N·m.
Automatic interference prevention function
When the sensors are mounted closely, use them in the
interference prevented area, as shown below.
L mm in
or more
L mm in
or more
L mm in
or more
0 150
5.906
50
1.969
250
9.843
200
7.874
100
3.937
Mounting interval L (mm in)
1
3.281
2
6.562
3
9.843
Setting distance (m ft)
Interference
prevented area
Note that the detection may be unstable depending on
the mounting conditions or the sensing object to be used.
In the state that this product is mounted, be sure to check
the operation with the actual sensing object to be used.
1
3.281
2
6.562
3
9.843
06
0
2.362
20
0.787
80
3.15
40
1.575
Setting distance (m ft)
Mounting interval L (mm in)
Interference
prevented area
L mm in
or more
Never use this product as a sensing device
for personnel protection.
In case of using sensing devices for
personnel protection, use products which
meet laws and standards, such as OSHA,
ANSI or IEC etc., for personnel protection
applicable in each region or country.
Correct Correct Incorrect