Datasheet

361
Adjustable Range Reective Photoelectric Sensor EQ-30 SERIES
Selection
Guide
Amplier
Built-in
Power Supply
Built-in
Amplier-
separated
CX-400
CY-100
EX-10
EX-20
EX-30
EX-40
CX-440
EQ-30
EQ-500
MQ-W
RX-LS200
RX
RT-610
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
SENSING CHARACTERISTICS (TYPICAL)
EQ-34W
Correlation between color (200 × 200 mm 7.874 × 7.874 in non-glossy paper) and sensing range
0
White
Yellow
Orange
Red
Brown
Green
Blue
Gray
Black
These bars indicate
the sensing range
with respective
colors when the
distance adjuster is
set at the sensing
range of Far (Main)
2 m 6.562 ft and
Near (Sub) 1 m
3.281 ft long, each,
with white color.
The sensing
distance varies
depending also on
material.
1
3.281
2
6.562
···
···
Far (Main)
2 m 6.562 ft
Near (Sub)
1 m 3.281 ft
Sensing range L (m ft)
Correlation between material (200 × 200 mm 7.874 × 7.874 in) and sensing range
0
These bars
indicate the
sensing range with
re- spective
objects when the
distance adjuster
is set at the
sensing range of
Far (Main) 2 m
6.562 ft and Near
(Sub) 1 m 3.281 ft
long, each, with
white non-glossy
paper.
White non-
glossy paper
Gray non-
glossy paper
(Lightness: 5)
Plywood
Black rubber
···
Far (Main)
2 m 6.562 ft
···
Near (Sub)
1 m 3.281 ft
Sensing range L (m ft)
Cardboard
1
3.281
2
6.562
PRECAUTIONS FOR PROPER USE
Refer to p.1458~ for general precautions.
Mounting
Stability indicator
Since the EQ-30 series uses a 2-segment photodiode as
its receiving element, and sensing is done based on the
difference in the incident beam angle of the reected beam
from the sensing object, the output and the operation
indicator operate according to the object distance.
Further, the stability indicator shows the margin of the
incident light intensity and not that of the object distance.
Hence, the distance at which it lights up/off depends
on the object reflectivity and is not at all related to the
output operation. Do not use the sensor when the stability
indicator is off (unstable light received condition), since
the sensing will be unstable.
Sensor
Setting distance
Sensing
object
Sensing
object
Sensing
object
Output
(operation indicator)
(In case of Detection-ON)
Stability indicator
(Black non-glossy paper)
Stability indicator
(White non-glossy paper)
OFF (Lights off)
ON (Lights up)
Stable light
received condition
Stable light received condition
Lights up
Lights off
Lights up
Lights off
Unstable light
received condition
Unstable light
received condition
Stable dark
condition
Stable dark
condition
Others
Do not use during the initial transient time (50 ms) after
the power supply is switched on.
When connecting the mating cable to the plug-in
connector type, the tightening torque should be 0.4 N·m
or less.
The tightening
torque should be
0.8 N·m or less.
M4 nut
M4 (length 25 mm 0.984 in)
screw with washers
Sensor
mounting
blacket
MS-EQ3-2
(Optional)
Care must be taken regarding the sensor mounting
direction with respect to the object’s direction of movement.
Sensing
object
Sensing
object
Sensing
object
Do not make the sensor
detect an object in this
direction because it may
cause unstable operation.
When detecting a specular object (aluminum or copper
foil) or an object having a glossy surface or coating, please
take care that there are cases when the object may not be
detected due to a small change in angle, wrinkles on the
object surface, etc.
When a specular body is present below the sensor, use the
sensor by tilting it slightly upwards to avoid wrong operation.
Specular
face
Tilt
If a specular body is present in the background, wrong
operation may be caused due to a small change in the
angle of the background body. In that case, install the
sensor at an inclination and conrm the operation with
the actual sensing object.
Take care that some objects may produce a dead zone
right (less than 0.1 m 0.328 ft) in front of the sensor.
Never use this product as a sensing device
for personnel protection.
In case of using sensing devices for
personnel protection, use products which
meet laws and standards, such as OSHA,
ANSI or IEC etc., for personnel protection
applicable in each region or country.
Correct Correct Incorrect
Incorrect Correct