Datasheet
Product Specification
E-XS-ML-5001-1
Specialty Polymer Aluminum Electrolytic Capacitors
(CX/SX)
6
6. Characteristics
No Item Characteristics Outline of test method
1 Leakage
current
Suffix code: S-R,XR
2V to 4V
I≤0.06CV
6.3V
I≤0.04CV
Suffix code: ER,XE,E4
CX-R
I≤0.1CV
Series resistor: 1000Ω
Applied voltage: Rated Voltage
Measuring: 2min
If you have doubts about the measured result,
please re-check after the pre-conditioning explained below.
Pre-conditioning
Apply rated DC voltage for 1h at 105°C through 1000Ω
series resistor: Then discharge and keep in the room
temperature for 24h to 48h
2 Capacitance
tolerance
±20%
3
tanδ
See attached individual
specification(P.3)
Measuring frequency: 120Hz±10%
Measuring circuit: Equivalent series circuit
Measuring voltage: +0V.DC≤0.5Vrms
Measuring temperature: 20°C
4 ESR See attached individual specification
(P.3)
Measuring frequency: 100kHz±10%
Measuring voltage: +0V.DC, ≤0.5Vrms
Measuring temperature: 20°C
5 Solder-
ability
More than 75% of the terminal face are
covered by new solder.
Solder type: H60A or H63A
Flax: About 25% rosin density melted ethanol
Solder temperature: 230±5°C
Immersing time: 2±0.5s
6 Solubility
resistance
to marking
Appearance: No remarkable abnormal
change shall be occurred.
Class of reagent: Extra grade 2-propanol
(JIS K8839) or superior.
Test temperature: 20°C to 25°C
Immersing time: 30±5s
Leakage
Current
≤The value of item 1.
Capacitance
Change
±10% of initial
measured value.
tanδ ≤The value of item 3.
7 Solder heat
resistance
Appearance No remarkable abnormal
change shall be occurred.
The capacitor is held on heating for reflow
soldering.
Reflow soldering profile:
Please refer to Chapter 10
(Page 15 to 16)
8 Adhesion Appearance:
Without mechanical damage such as
breaks after test.
Push direction: Side
Force: 5.0N
Holding time: 10±0.5s
Leakage
Current
≤The value of item 1.
Capacitance
Change
+70%,-20% (2V,2.5V)
+60%,-20% (4V)
+50%,-20% (6.3V)
of initial measured value.
tanδ ≤200% of initial specified
value.
9 Damp heat,
Steady state
Appearance No remarkable abnormal
change shall be occurred.
Test temperature: 60±2°C
Relative humidity: 90%
Test time: 500
+24
0
h
Panasonic Electronic Devices Co.,Ltd
Design, Specifications are subject to change without notice. Contact your nearest Panasonic sales office for the latest specifications prior to purchase and/or use. Whenever any doubt
about safety comes up with this product, please contact us immediately for engineering assistance without fail. Specifications are typical and may not apply to all applications.