Datasheet

Plastic Film Capacitors
Design, Specifications are subject to change without notice. Ask factory for technical specifications before purchase and/or use.
Whenever a doubt about safety arises from this product, please inform us immediately for technical consultation without fail.
Metallized Polypropylene Film Capacitor
Type: ECQUA [Class X2]
In accordance with UL/CSA and European safety
regulation class X2
Features
Compact
Flame-retardant plastic case and non-combustible resin
RoHS directive compliant
Recommended Applications
Interference suppressors
Explanation of Part Numbers
Applicable Standard
UL UL 60384-14
Across-The-Line Capacitors
Antenna-Coupling and Line-By-Pass Components
(0.10 μF to 2.2μF)
CSA CAN/CSA E60384-14
Across-the-line capacitors
Antenna-isolation and line-by-pass capacitors
(0.10 μF to 2.2 μF)
Accredited
by UL
Europe EN 60384-14 Class X2 (0.10 μF to 2.2 μF)
International IEC 60384-14 Class X2 (0.10 μF to 2.2 μF)
Accredited
by VDE
When applying this capacitor to European and American safety standards, please use type designation and rating
such as ECQUA0.1μF.
Approval number (File No.) of safety regulations are subject to revision without notice. Ask factory for a copy of the
latest file No
Specifications
Category temp. range 40 to 110
Rated voltage 275 VAC (Safety standard approval)
Capacitance range 0.10 to 2.2μF
Capacitance tolerance ±10 (K),±20 (M)
Dissipation factor (tanδ)
C≦1.0μF:tanδ≦0.1 (20 ,1 kHz)
C>1.0μF:tanδ≦0.2 (20 ,1 kHz)
Withstand voltage
Between terminals: 633 VAC1183VDC 60s
Between terminals to enclosure: 2050 VAC 60 s
Insulation resistance (IR)
C0.33μF : IR15000 MΩ (20 , 100 VDC, 60 s)
C0.33μF : IR5000 MΩ・μF 20 , 100 VDC, 60 s
C0.47μF :IR2000 MΩ(20 , 500 VDC, 60 s
Maximum AC voltage
310 VAC
Use of this capacitor is limited to AC voltage (50Hz or 60Hz sine wave).
Suitable for series to the mains usage - for more details, please contact your Panasonic contact person.
(no influence of corona discharge at rated voltage)
Maximum AC voltage including line voltage fluctuation is 310V AC.
310VAC is not nominal continuous applied voltage, but only indicates maximum value including fluctuation in the voltage
of the power supply. Basic nominal voltage is considered as 240V AC.
This maximum AC voltage is specified in only ECQUA type, not specified in other types.
Please refer to individual product specification, and contact us for further questions regarding design life.
E C Q U A A F
Product code
Dielectric &
construction
Rated voltage Capacitance
Su
ffix Cap. Tol.
K
M
±
10%
±
20%
Blank
Strai
g
ht
A
Cut lead
12

Summary of content (3 pages)