Multilayer Ceramic Capacitors(100V, 200V Series)
– EC33 –
Temperature
Characteristic Code
Temperature
Characteristics
Temp. Coeff.
(ppm/°C)
Rate of Capacitance change at each Temp. (%)
–25 °C 85 °C
max. min. max. min.
CCH0 ± 60 0.49 –0.27 0.39 –0.39
■ Temperature Characteristics
● Class 1
● Class 2
Temperature
Characteristic Code
Temperature
Characteristics
Capacitance Change
Measurement
Temperature Range
Reference Temperature
B
B±10 %–25 to 85 °C 20 °C
X7R ±15 % –55 to 125 °C 25 °C
■ Rated Voltage
Code 2A 2D
Rated Voltage DC 100 V DC 200 V
■ Nominal Capacitance
Ex. 100 101104105
Nominal
Capacitance
10 pF 100 pF
100,000 pF
(0.1 µF)
1,000,000 pF
(1.0 µF)
Class Temperature Characteristics Tolerance Code Capacitance Tolerance
1CHCapacitance range
C=10 pF D±0.5 pF
C>10 pF
J±5 %
K±10 %
2B, X7R
K±10 %
M±20 %
■ Capacitance tolerance
■ Specifi cations and Testing Methods
Item
Specifi cations
Test Method
Class 1 Class 2
Operating
Temperature
Range
–55 to 125 °C
———
Dielectric
Withstanding
Voltage
No dielectric breakdown and/or damage Test voltage:
Class 1: Rated voltage
҂
300 %
Class 2: Rated voltage
҂
250 %
Duration: 1 to 5 s
Charge/discharge current: 50 mA max.
Insulation
Resistance (IR)
10000 M
액
or 500/C (M
액
) Whichever is less
C: Nominal Cap. in µF
Measuring voltage: Rated voltage
Duration: 60±5 s
Charge/discharge current: 50 mA max.
Capacitance Within the specifi ed tolerance Measuring temperature: 20±2 °C
Class 1
Nominal capacitance C
<
1000 pF C > 1000 pF
Measuring frequency 1 MHz±10 % 1 kHz±10 %
Measuring voltage0.5 to 5 Vrms 0.5 to 5 Vrms
Class 2
Preconditioning: The capacitors shall be
kept in temperature of 150 +0/–10 °C for 1
hour and subjected to standard conditions
✽
for 48±4 hours before initial measurement.
Nominal capacitance C
<
1 µF
Measuring frequency 1 kHz±10 %
Measuring voltage1.0±0.2 Vrms
Q Factor or
Dissipation Factor
(tan
δ
)
Q:
C < 30 pF: Q
>
400+20 C
30 pF
<
C
<
1000 pF:
Q
>
1000
tan
δ
:
C > 1000 pF: tan
δ
<
0.002
C: Nominal Cap. in pF
tan
δ
:0.025 max.
✽
Standard condition: Temperature 15 to 35 °C, Relative humidity 45 to 75 %.
For further information, see the technical specifi cations.
Note: Temperature coeffi cient: calculated between 20 °C to 85 °C
For applicable “temperature characteristics”, see the lists of standard products on page 34 to 35.
00 Sep. 2008