Datasheet
DSP
–6–
ASCTB180E 201604-T
SAFETY STANDARDS
* Remarks: The standard certified for may differ depending on where the product was manufactured.
NOTES
Item
UL (Recognized) CSA (Certified) TÜV (Certified)
File No. Contact rating File No. Contact rating File No. Contact rating
1 Form A
E43028 8A 125/250V AC General use
1
/6HP 125/250V AC
5A 30V DC Resistive
B300
LR26550 8A 125/250V AC General use
1
/6HP 125/250V AC
5A 30V DC Resistive
B300
B 13 11
13461 342
8A 250V AC (cos
φ
=1.0)
5A 250V AC (cos
φ
=0.4)
5A 30V DC (0 ms)
1 Form A
1 Form B
E43028 5A 125/250V AC General use
1
/6HP 125/250V AC
5A 30V DC Resistive
30W Max.: 1A 30V DC-0.24A
125V DC
LR26550 5A 125/250V AC General use
1
/6HP 125/250V AC
5A 30V DC Resistive
30W Max.: 1A 30V DC-0.24A
125V DC
B300
B 13 11
13461 342
5A 250V AC (cos
φ
=1.0)
3A 250V AC (cos
φ
=0.4)
5A 30V DC (0 ms)
2 Form A
E43028 5A 125/250V AC General use
1
/10HP 125/250V AC
5A 30V DC Resistive
LR26550 5A 125/250V AC General use
1
/10HP 125/250V AC
5A 30V DC Resistive
B 13 11
13461 342
5A 250V AC (cos
φ
=1.0)
3A 250V AC (cos
φ
=0.4)
5A 30V DC (0 ms)
1. For cautions for use, please read
“GENERAL APPLICATION
GUIDELINES”.
2. Soldering conditions
Please obey the following conditions
when soldering automatically.
1) Preheating: Within 120°C 248°F and
within 120 seconds
2) Soldering iron: 260°C±5°C
500°F±41°F and within 6 seconds
3. Cleaning
For automatic cleaning, the boiling
method is recommended. Avoid
ultrasonic cleaning which subjects the
relays to high frequency vibrations, which
may cause the contacts to stick.
It is recommended that a fluorinated
hydrocarbon or other alcoholic solvents
be used.
4. External magnetic field
Since DSP relays are highly sensitive
polarized relays, their characteristics will
be affected by a strong external magnetic
field. Avoid using the relay under that
condition.
5. Coil operating power
Pure DC current should be applied to the
coil. The wave form should be
rectangular. If it includes ripple, the ripple
factor should be less than 5%.
However, check it with the actual circuit
since the characteristics may be slightly
different.
6. When using, please be aware that
the a contact and b contact sides of
1 Form A 1 Form B type may go on
simultaneously at operate time and
release time.