Datasheet

DS
–3–
ASCTB17E 201504-T
2. Specifications
Notes: *1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load. TX/TX-S/TX-D relay AgPd contact type are available for low level load switching (10V DC, 10mA max. level).
*2 Half-wave pulse of sine wave: 11ms; detection time: 10μs
*3 Refer to “AMBIENT ENVIRONMENT” in GENERAL APPLICATION GUIDELINES.
Characteristics Item Specifications
Contact
Arrangement 1 Form C 2 Form C
Initial contact resistance, max. Max. 50 mΩ (By voltage drop 6 V DC 1A)
Contact material Ag+Au clad
Rating
Nominal switching capacity 2 A 30 V DC (resistive load)
Max. switching power 60 W, 125 VA (resistive load)
Max. switching voltage 220 V DC, 250 V AC
Max. carrying current 3 A
Min. switching capacity (Reference value)*
1
10μA 10m V DC
Nominal operating power
Single side stable (M type: 400 mW, S type: 200 mW);
latching (M type: 360 mW, S type: 180 mW)
Electrical
characteristics
Insulation resistance (Initial)
Min. 100MΩ (at 500V DC)
Measurement at same location as “Initial breakdown voltage” section.
Breakdown voltage
(Initial)
Between open contacts
1,000 Vrms for 1min.
(500 Vrms for 1min: 1 Form C type) (Detection current: 10mA.)
Between contact and coil
1,500 Vrms for 1min.
(1,000 Vrms for 1min: 1 Form C type) (Detection current: 10mA.)
Temperature rise
Max. 65°C
(By resistive method, nominal coil voltage applied to the coil, contact carrying current: 2A.)
Operate time [Set time] (at 20°C 68°F) Max. 10 ms [10 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.)
Release time [Reset time] (at 20°C 68°F)
Max. 5 ms [10 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.)
(without diode)
Mechanical
characteristics
Shock resistance
Functional*
2
Min. 490 m/s
2
Min. 490 m/s
2
Destructive Min. 980 m/s
2
(Half-wave pulse of sine wave: 6 ms.)
Vibration resistance
Functional 10 to 55 Hz at double amplitude of 3.3 mm (Detection time: 10μs.)
Destructive 10 to 55 Hz at double amplitude of 5 mm
Expected life
Mechanical Min. 10
8
(10
7
: 1 Form C latching type) (at 600 cpm)
Electrical Min. 5×10
5
rated load (at 60 cpm)
Conditions
Conditions for operation, transport and storage*
3
Ambient temperature: –40°C to +70°C –40°F to +158°F
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Max. operating speed (at rated load) 60 cpm
Unit weight Approx. 3 g .11 oz Approx. 4g .14oz