13
DP-100
PRECAUTIONS FOR PROPER USE
PRO mode
Setting item Description
Reset setting
ECO mode setting
Linked display color
switching
(standard type only)
Display refresh rate
switching
Hysteresis fix value
switching
Setting check code
Setting copy mode
Sensor
DP-10
Table of codes
ADJ.
NO
OFF
OFF
P-1, Lo-1
NC
NO
Hi-1
NO
NC
P-2, Lo-2
NC
NO
Hi-2
NO
NC
NC
NC
NO
EASY
EASY
Analog voltage output /
External input
NO / NC
switching
Comparative output 2
output mode
Comparative output 1
output mode
NO / NC
switching
Display color for
main display
Threshold
value display
Display
color linking
Code
2.5 ms MPa 250 ms OFF
5 ms kPa 500 ms STD
10 ms kgf/cm
2
1,000 ms FULL
25 ms bar
50 ms psi
100 ms mmHg
250 ms inchHg
500 ms
1,000 ms
5,000 ms
Code
20
0.787
20
0.787
M3 female thread, 4 0.157 deep
M5 female thread
12
0.472
Connector
1.5
0.059
30
1.181
30
1.181
9.5
0.374
42.5
1.673
7.5
0.295
R (PT)
1
/8
male thread
(North American: NPT
1
/8)
25.5
1.004
If the mode selection key is pressed and held for 5 seconds in
RUN mode, the mode will switch to PRO mode.
If the mode selection key is pressed while a setting is being made,
the mode will switch to RUN mode. In this case, the settings that
have been changed will be entered.
•
•
Sub display switching
Changes the information in the sub display
during RUN mode operation to the desired
alphanumeric display.
Changes the display refresh rate for the
pressure value displayed in the main display.
Sets the response time for EASY mode and
window comparator mode. (8 steps)
Allows the display color for the main display to
be switched in line with the output operation for
comparative output 1 or comparative output 2.
Allows power consumption to be reduced by
dimming the display or turning it off.
Allows the setting details to be checked via
codes.
Allows the setting details for the master sensor
to be copied to slave sensors.
Resets the settings to the factory settings.
1st digit
2nd digit
3rd digit
4th digit
Standard
type only
Multi-function
type
Standard type
Hysteresis
Hysteresis
Red
when ON
Comparative
output 1
Comparative
output 2
Comparative
output 1
Comparative
output 2
Comparative
output 1
Comparative
output 2
Comparative
output 1
Comparative
output 2
Green
when ON
Always
red
Always
green
Analog voltage
output
Auto-
reference
Remote
zero-adjustment
Window
comparator
Window
comparator
5th digit 6th digit 7th digit 8th digit
Response time Unit switching
Display reflesh rate
ECO mode
DIMENSIONS (Unit: mm in)
The CAD data in the dimensions can be downloaded from the SUNX website: http://www.sunx.co.jp/
European
G
1
/8
male thread
10
0.394
7
0.276
14
0.551
European