I/O CIRCUIT AND WIRING DIAGRAMS
PRECAUTIONS FOR PROPER USE
Never use this product as a sensing device for
personnel protection.
In case of using sensing devices for personnel
protection, use products which meet laws and standards,
such as OSHA, ANSI or IEC etc., for personnel
protection applicable in each region or country.
The DP-100 series is designed for use with non-corrosive
gas. It cannot be used with liquid or corrosive gas.



Wiring
Make sure that the power supply is off while wiring.
Verify that the supply voltage variation is within the rating.
If power is supplied from a commercial switching regulator, ensure
that the frame ground (F.G.) terminal of the power supply is
connected to an actual ground.
In case noise generating equipment (switching regulator, inverter
motor, etc.) is used in the vicinity of this sensor, connect the frame
ground (F.G.) terminal of the equipment to an actual ground.
Do not run the wires together with high-voltage lines or power lines or put
them in the same raceway. This can cause malfunction due to induction.
Incorrect wiring will cause problems with operation.






Connection
Do not apply stress directly to the
connection cable leader or to the
connector.

Connector
attached cable
[CN-14A(-R)-CƑ]
Conditions in use for CE conformity
The DP-100 series is a CE conformity product complying with
EMC Directive. The harmonized standard with regard to immunity
that applies to this product is EN 61000-6-2 and the following
condition must be met to conform to that standard.

The MS-DP1-2 panel mounting bracket (optional) and the MS-DP1-3
front protection cover (optional) are also available.

Condition
Mounting
The line to connect with this sensor should be less than
30 m 98.425 ft.

MS-DP1-1 / MS-DP1-5 sensor mounting brackets are available
separately, and it should be used for mounting. When tightening
the sensor to the sensor mounting bracket, use a tightening torque
of 0.5 N·m or less.

Sensor mounting bracket
MS-DP1-1 (Optional)
M3 (length 6 mm 0.236 in)
screws with washers
Accessory for MS-DP1-1
and MS-DP1-5
PNP output type
'3Ƒ(3-
Terminal Designation
+V
0 V
Standard type: Comparative output 2
Multi-function type: Analog output or External input
Comparative output 1
Terminal arrangement diagram
1
2
3
4
I/O circuit diagram
12 to 24 V DC
±
10 %
+
í
(Black) Comparative output 1
Load
Load
(White) Comparative output 2
Tr1
ZD2
ZD1
Tr2
100 mA max.
100 mA max.
(Blue) 0 V
D
Standard type
1
4
2
3
Users’ circuitInternal circuit
Sensor circuit
Terminal No.
Color code of connection cable
(Brown) +V
1 k
Z
D1
D1
D2
(White) Analog voltage output
or External input
Load
(Black)
Comparative output 1
Tr1
Tr2
100 mA max.
Multi-function type
1
4
2
3
Users’ circuitInternal circuit
12 to 24 V DC
±
10 %
+
í
(Brown) +V
(Blue) 0 V
Sensor circuit
Terminal No.
Color code of connection cable
Symbols D : Reverse supply polarity protection diode
Z
D1, ZD2 : Surge absorption zener diode
T
r1, Tr2 : PNP output transistor
Symbols D1, D2 : Reverse supply polarity protection diode
Z
D1: Surge absorption zener diode
T
r1 : PNP output transistor
T
r2 : NPN input transistor
Front protection cover
MS-DP1-3
(optional)
Panel mounting bracket
MS-DP1-2
(optional)
( )
1
2
3
4