Datasheet
DP-100
9
ORDER GUIDE
Accessory
CN-14A-C2
(Connector attached cable 2 m 6.562 ft)
Type without connector attached cable
Type without connector attached cable CN-14A-C2 is available. When ordering this type, suffix “-J” to the end of Model No.
(e.g.) Type without connector attached cable of DP-101-N is “DP-101-N-J”
Standard pressure port type Short pressure port type
Asia
Europe
Asia
North America
Standard
Multi-function
Standard
Multi-function
For low pressure
For high pressure
For low pressure
For high pressure
For low pressure
For high pressure
For low pressure
For high pressure
Standard
Multi-function
For low pressure
For high pressure
For low pressure
For high pressure
Rated pressure range Model No. Pressure portType
NPN open-collector transistor
PNP open-collector transistor
NPN open-collector transistor
PNP open-collector transistor
NPN open-collector transistor
PNP open-collector transistor
NPN open-collector transistor
PNP open-collector transistor
NPN open-collector transistor
PNP open-collector transistor
NPN open-collector transistor
PNP open-collector transistor
NPN open-collector transistor
PNP open-collector transistor
NPN open-collector transistor
PNP open-collector transistor
NPN open-collector transistor
PNP open-collector transistor
PNP open-collector transistor
M5 female thread
+
R
1
/8
male thread
M5 female thread
+
G
1
/8
male thread
M5 female thread
M5 female thread
+
G
1
/8
male thread
í100.0 to +100.0 NPa
í0.100 to +1.000 MPa
í100.0 to +100.0 NPa
í0.100 to +1.000 MPa
í100.0 to +100.0 NPa
í0.100 to +1.000 MPa
í100.0 to +100.0 NPa
í0.100 to +1.000 MPa
í100.0 to +100.0 NPa
í0.100 to +1.000 MPa
í100.0 to +100.0 NPa
í0.100 to +1.000 MPa
Comparative output
DP-101
DP-102
DP-101A
DP-102A
DP-101-E-P
DP-102-E-P
DP-101A-E-P
DP-102A-E-P
DP-111-E-P-J
DP-112-E-P-J
DP-111A-E-P-J
DP-112A-E-P-J
DP-101-N
DP-101-N-P
DP-102-N
DP-102-N-P
DP-101A-N
DP-101A-N-P
DP-102A-N
DP-102A-N-P
DP-101-M
DP-101-M-P
DP-102-M
DP-102-M-P
DP-101A-M
DP-101A-M-P
DP-102A-M
DP-102A-M-P
Appearance
* CN-14A-C2
(
Connector attached
cable 2 m 6.562 ft
)
is attached.
(
Excluding M8 plug-in
connector type
)
Standard
Multi-function
For low pressure
For high pressure
For low pressure
For high pressure
M8 plug-in connector type
Standard
Multi-function
For low pressure
For high pressure
For low pressure
For high pressure
í100.0 to +100.0 NPa
í0.100 to +1.000 MPa
í100.0 to +100.0 NPa
í0.100 to +1.000 MPa
í100.0 to +100.0 NPa
í0.100 to +1.000 MPa
í100.0 to +100.0 NPa
í0.100 to +1.000 MPa
M5 female thread
+
NPT
1
/8
male thread
Flat installation on the wall by shifting the direction
of the pressure port
By mounting the flat attachment
to DP-10
Ƒ
-M(-P), pressure port
and cable can now be pulled out
in downward, left or right
directions. Flat mounting on
surfaces such as the wall is
made possible.
For short pressure port type For short pressure port type
Rc
1
/8 conversion bushing is available. Compatible
with previous model
By equipping the push-in converter with DP-10
Ƒ
-M(-P), pressure
port can be converted from M5 female thread to Rc
1
/8
female thread.
Bore diameter conversion to the DP2 / DP3 series is possible.
MS-DP1-7
M5 female thread Rc
1
/8
female thread
Conversion bushing
Flat attachment
3 possible directions to mount
06'3)Ƒ
20 mm
0.787 in pitch
Previous model
Model No. Pressure port
MS-DP1-FM
MS-DP1-FR
MS-DP1-FN
MS-DP1-FE
M5 female thread
Rc
1
/8 female thread
NPT
1
/8 female thread
G
1
/8 female thread
Previous model DP2 / DP3
series can be switched over to
DP-100 series.
20 mm
0.787 in pitch