Datasheet

DE (ADE)
3
ds_61A01_en_de: 150313D
3) 2 coil latching type
2. Specifications
Notes:
*1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual
load.
*2. Wave is standard shock voltage of 1.250s according to JEC-212-1981
*3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to “6. Usage, Storage and Transport
Conditions“ in AMBIENT ENVIRONMENT section in Relay Technical Information.
*4. 16A possible for one cantact set only with max. 4000VA switching power.
Nominal coil
voltage
Set voltage
(at 20C 68F)
Reset voltage
(at 20C 68F)
Nominal operating
current
[10%] (at 20C 68F)
Coil resistance
[10%] (at 20C 68F)
Nominal operating
power
Max. applied voltage
(at 20C 68F)
Set coil Reset coil Set coil Reset coil Set coil Reset coil
1.5V DC
70%V or less of
nominal voltage
(Initial)
70%V or less of
nominal voltage
(Initial)
66.6mA 66.6mA 11.3 11.3
200mW 200mW
130%V of
nominal voltage
3V DC 66.6mA 66.6mA 45 45
4.5V DC 44.5mA 44.5mA 101 101
5V DC 40mA 40mA 125 125
6V DC 33.3mA 33.3mA 180 180
9V DC 22.2mA 22.2mA 405 405
12V DC 16.6mA 16.6mA 720 720
24V DC 8.3mA 8.3mA 2,880 2,880
Characteristics Item Specifications
Contact
Arrangement 1 Form A 1 Form A 1 Form B 2 Form A
Contact resistance (Initial) Max. 30 m (By voltage drop 6 V DC 1A)
Contact material AgSnO
2 type
Rating
Nominal switching capacity (resistive load) 10A 250V AC, 10A 30V DC 8A 250V AC, 8A 30V DC
Max. switching power (resistive load) 2,500VA*
4
, 300W 2,000VA*
4
, 240W
Max. switching voltage 440V AC, 230V DC 440V AC, 230V DC
Max. switching current 10A (16A)*
4
8A (16A)*
4
Nominal operating power Single side stable, 2 coil latching: 200mW; 1 coil latching: 100mW
Min. switching capacity*
1
100mA 5V DC
Electrical
characteristics
Insulation resistance (Initial) Min. 1,000M (at 500V DC) Measurement at same location as “Breakdown voltage” section.
Breakdown voltage
(Initial)
Between open contacts 1,000 Vrms for 1 min. (Detection current: 10 mA)
Between contact sets 4,000 Vrms for 1 min. (Detection current: 10 mA)
Between contact and coil 5,000 Vrms for 1 min. (Detection current: 10 mA)
Surge breakdown voltage*
2
(Between contact and coil) (Initial)
12,000 V
Temperature rise (coil) (at 70C 158F) Max. 50C 122F (By resistive method)
Operate time [Set time] (at 20C 68F)
Max. 10 ms (typ. 5ms)
Max. 10 ms (typ. 4ms)
(Nominal coil voltage applied to the coil, excluding contact bounce time.)
Release time [Reset time] (at 20C 68F)
Max. 5 ms (typ. 2ms)
Max. 10 ms (typ. 4ms)
(Nominal coil voltage applied to the coil, excluding contact bounce time.) (without diode)
Mechanical
characteristics
Shock resistance
Functional Min. 196 m/s
2
(Half-wave pulse of sine wave: 11 ms; detection time: 10s.)
Destructive Min. 980 m/s
2
(Half-wave pulse of sine wave: 6 ms.)
Vibration resistance
Functional 10 to 55 Hz at double amplitude of 2 mm (Detection time: 10s.)
Destructive 10 to 55 Hz at double amplitude of 3 mm
Expected life
Mechanical Min. 10
7
(at 300 times/min.)
Electrical
Min. 10
5
(resistive load, at 20 times/min., at nominal switching capacity)
Min. 10
5
(resistive load,
at 20 times/min., at AC nominal
switching capacity)
Min. 510
4
(resistive load,
at 20 times/min., at DC nominal
switching capacity)
Electrical (16A/230V AC resistive)*
4
25000 2000
Conditions
Conditions for operation, transport and storage*
3
Ambient temperature: –40C to +70C –40F to +158F;
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Max. operating speed 20 times/min. (at nominal switching capacity)
Unit weight Approx. 7 g .25 oz