Datasheet
5
2. Specification
2.1 CS-UE9HKE CU-UE9HKE
Item Unit Indoor Unit Outdoor Unit
kW 2.60(0.90~3.00)Capacity
BTU/h 8870(3070~10230)
W/W 3.25(4.74~3.00)EER
BTU/hW 11.06(16.16~10.23)
dB(A) Hi: 42 Lo: 27 QLo: 25 Hi: 47
COOLING
Noise Level
Power level dB 53 60
kW 3.30(0.90~3.90)Capacity
BTU/h 11250(3070~13300)
W/W 3.79(5.29~3.68)COP
BTU/hW 12.93(18.06~12.55)
dB(A) Hi: 42 Lo: 27 QLo: 26 Hi: 47
HEATING
Noise Level
Power level dB 53 60
l/h 1.5Moisture Removal
(pt/h) 2.6
Quiet m
3
/m (ft
3
/m) 6.30 (222) -
Lo m
3
/m (ft
3
/m) 7.08(249) -
Me m
3
/m (ft
3
/m) 9.13(322) -
Hi m
3
/m (ft
3
/m) 11.6 (409) 28.9 (1020)
Air Volume
Powerful m
3
/m (ft
3
/m) 12.28 (432) -
Refrigerant Control Device - Capillary Tube
Refrigerant Oil (Charged) cm
3
- RB68A or Freol Alpha68M
Refrigerant (Charged) R410A kg (oz) - 0.78(26.1)
Length mm (inch) 799 (31-15/32) 780 (30-23/32)
Width mm (inch) 183 (7-13/64) 289 (11-3/8)
Dimension
Heigth mm (inch) 280 (11-1/32) 540 (21-1/4)
Net Weight kg (lbs) 8.5 (19) 28 (62)
Gas mm (inch) 9.52 (3/8)Pipe Diameter
Liquid mm (inch) 6.35 (1/4)
Pipe Length m (ft) 3 (9.8) - 15(49.2)
Height Difference m (ft) 5 (16.4)
Additional Gas Amount g/m (oz/ft) 20 (0.2)
Refrigerant Charge Less m (ft) 7.5(24.6)
Inner diameter mm 14 -Drain Hose
Length mm 500 -
Type - Rotary
Motor Type - Induction (6-poles)
Compressor
Rated Output W - 750
Type Cross-Flow Fan Propeller Fan
Material AS PP
Motor Type Induction (8-poles) Induction (6-poles)
Input power W - -
Output power W 30 15
Quiet rpm 740
Lo rpm 830 -
Me rpm 1070 -
Hi rpm 1360 750
Fan
Fan Speed
Powerful rpm 1440
Fin material Aluminium (Pre Coated) Aluminum ( Pre Coated)
Fin type Slit Fin Slit Fin
Row x stage x FPI 2 x 15 x 20 1 x 24 x 17
Heat
Exchanger
Size (W x H x L) mm 610 x 315 x 25.4 713 x 504 x 18.2
Material P.P.HONEY COMB -Air Filter Type
Style One-Touch -
1. Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19°C Wet Bulb (66.2°FWetBulb)
and outdoor air temperature of 35°C Dry Bulb (95.0°F Dry Bulb), 24°C Wet Bulb (75.2°FWetBulb).
2. Heating capacities are based on indoor temperature of 20°C Dry Bulb (80.6°F Dry Bulb) and outdoor air temperature of 7°C
Dry Bulb (44.6°F Dry Bulb), 6°C Wet Bulb (42.8°FWetBulb).