Datasheet

NEW
Possible indoor unit combinations
Models Possible indoor unit
combinations
Capacity
kW
1
Refrigerant pipe diameter Pipe length Indoor/outdoor unit combinations
Indoor
unit
Liquid Gas
Max. pipe
length
(1 room)
Max. pipe
length
(total)
Max. pipe
without
additional
gas refills
Additional
gas
Max. level
difference
Capacity Split
Etherea
Floor
console
Low Static
Pressure
Hide Away
4 Way
60x60
Cassette
ROOMS
2 CU-2E15PBE
A
2
: 5, 7, 9/10 or 12 4.0-5.6 Room A 1/4 3/8 20 m 30 m 20 m 20 g/m 10 m 7
B
2
: 5, 7, 9/10 or 12 Room B 1/4 3/8
9/10
✔✔✔✔
12
✔✔
CU-2E18PBE
A
2
: 5, 7, 9/10 or 12 4.0-6.4 Room A 1/4 3/8 20 m 30 m 20 m 20 g/m 10 m 7
B
2
: 5, 7, 9/10 or 12 Room B 1/4 3/8
9/10
✔✔✔✔
12
✔✔
3 CU-3E18PBE
A³: 5, 7, 9/10, 12, 15 or 18 4.5-9.0 Room A 1/4 3/8 25 m 50 m 30 m 20 g/m 15 m 7
B³: 5, 7, 9/10, 12, 15 or 18 Room B 1/4 3/8 9/10
✔✔✔✔
C³: 5, 7, 9/10, 12, 15 or 18 Room C 1/4 3/8 12
✔✔
14/15
✔✔
18
✔✔✔✔
4 CU-4E27PBE
A³: 5, 7, 9/10, 12, 15, 18 or 21 4.5-11.0 Room A 1/4 3/8 25 m 60 m 30 m 20 g/m 15 m 7
B³: 5, 7, 9/10, 12, 15, 18 or 21 Room B 1/4 3/8 9/10
✔✔✔✔
C³: 5, 7, 9/10, 12, 15, 18 or 21 Room C 1/4 3/8 12
✔✔
D³: 5, 7, 9/10, 12, 15, 18 or 21 Room D 1/4 3/8 14/15
✔✔
18
✔✔✔✔
21
✔✔
CU-4E27PBE
A³: 7, 9/10, 12, 15 or 18 4.5-13.6 Room A 1/4 3/8 25 m 70 m 40 m 20 g/m 15 m 7
B³: 7, 9/10, 12, 15 or 18 Room B 1/4 3/8 9/10
✔✔✔✔
C³: 7, 9/10, 12, 15 or 18 Room C 1/4 3/8 12
✔✔
D³: 7, 9/10, 12, 15 or 18 Room D 1/4 3/8 14/15
✔✔
18
✔✔✔✔
5 CU-5E34PBE
A³: 7, 9, 12, 18 or 24 Room A 1/4 3/8 30 m 80 m 45 m 20 g/m 15 m 7
B³: 7, 9, 12, 18 or 24 Room B 1/4 3/8 9
C³: 7, 9, 12, 18 or 24 Room C 1/4 3/8 12
D³: 7, 9, 12, 18 or 24 Room D 1/4 1/2 18
E³: 7, 9, 12, 18 or 24 Room E 1/4 1/2 24
1. The combinations must remain within this range. 2. A minimum of two indoor units must be connected. 3. A minimum of two indoor units must be connected. minimum combination at 2x1: 7+9.
Connectivity restriction: CS-E/XE_PKE units are only compatible with CU-2E15PBE, CU-2E18PBE, CU-3E18PBE, CU-4E27PBE and CU-4E27PBE outdoor units. No other outdoor unit can be connected.
ROTARY
INVERTER COMPRESSOR
61
DOMESTIC
NEW