Datasheet

Etherea with enhanced Econavi sensor and new Nanoe-G air-purifying system: outstanding
efficiency, comfort and healthy air combined with state-of-the-art design
Econavi features a Human Activity sensor and a new Sunlight Detection technology to adjust output ideally
thereby giving you the best comfort at anytime whilst saving energy. Furthermore, the Nanoe-G revolutionary
air-purifying system utilises nano technology fine particles to remove and deactivate 99% of both airborne and
adhesive micro-organisms like bacteria, viruses and mould. Etherea is more efficient than ever with 64% less
consumption for the non Inverter model on heat pump mode, and can reach 71% total savings when used with
Econavi.
Using a Multi Split 4x1 Inverter+ system with the outdoor unit CU-4E27PBE instead of 4 individual mono split
Inverter+ systems, you reduce consumption and thus save more! Up to 36%! Furthermore, using a Multi Split
system, you save space on the outdoor unit, making it easier to install in small spaces.
ETHEREA MULTI SPLIT 4x1
INVERTER+
INTERNET CONTROL READY: Optional.
A class
energy saving
Easy
control
by BMS
CONNECTIVITY
5 year
compressor
warranty
Up to 71%
savings with
Econavi
Air purifier
99%
removal
bacteria · virus · mold
Down to
-15 ºC in
heating mode
OUTDOOR
TEMPERATURE
Improved
comfort
AUTOCOMFORT
Internet
Control
Ready
INTERNET CONTROL
OPTIONAL
Silver Kit KIT-4XE77712-PBE KIT-4XE77715-PBE KIT-4XE77712-PKE KIT-4XE77715-PKE
Silver Kit with Smartphone Control KIT-4XE77712-PBE-WIFI KIT-4XE77715-PBE-WIFI KIT-4XE77712-PKE-WIFI KIT-4XE77715-PKE-WIFI
Indoor CS-XE7PKEW (x3) +
CS-XE12PKEW (x1)
CS-XE7PKEW (x3) +
CS-XE15PKEW (x1)
CS-XE7PKEW (x3) +
CS-XE12PKEW (x1)
CS-XE7PKEW (x3) +
CS-XE15PKEW (x1)
White Kit KIT-4E5557-PBE KIT-4E77712-PBE KIT-4E77715-PBE KIT-4E77712-PKE KIT-4E77715-PKE
White Kit with Smartphone Control KIT-4E5557-PBE-WIFI KIT-4E77712-PBE-WIFI KIT-4E77715-PBE-WIFI KIT-4E77712-PKE-WIFI KIT-4E77715-PKE-WIFI
Indoor CS-ME5PKEW (x3) +
CS-E7PKEW (x1)
CS-E7PKEW (x3) +
CS-E12PKEW (x1)
CS-E7PKEW (x3) +
CS-E15PKEW (x1)
CS-E7PKEW (x3) +
CS-E12PKEW (x1)
CS-E7PKEW (x3) +
CS-E15PKEW (x1)
Outdoor CU-4E23PBE CU-4E23PBE CU-4E23PBE CU-4E27PBE CU-4E27PBE
Cooling capacity Nominal (Min - Max) kW 6.80 (1.90 - 8.80) 6.80 (1.90 - 8.80) 6.80 (1.90 - 8.80) 8.00 (2.80 - 8.90) 8.00 (2.80 - 8.90)
Nominal (Min - Max) kCal/h 5,850 (1,630 - 7,570) 5,850 (1,630 - 7,570) 5,850 (1,630 - 7,650) 6,880 (2,410 - 7,650) 6,880 (2,410 - 7,650)
EER
1)
Nominal (Min - Max) Energy Saving
4.05 (5.59 - 3.56)
A
4.12 (5.59 - 3.56)
A
4.12 (5.59 - 3.56)
A
3.76 (5.71 - 3.09)
A
3.76 (5.71 - 3.20)
A
SEER Nominal Energy Saving
7.00
A++
Pdesign (cooling)
6.80
Power input Cooling Nominal (Min - Max) kW 1.68 (0.34 - 2.47) 1.65 (0.34 - 2.47) 1.65 (0.34 - 2.47) 2.13 (0.49 - 2.88) 2.10 (0.49 - 2.87)
Annual Energy Consumption (cooling)
2)
kWh 340
Heating capacity Nominal (Min - Max) kW 8.50 (3.00 - 10.60) 8.60 (3.00 - 10.60) 8.60 (3.00 - 10.60) 9.40 (3.40 - 10.50) 9.40 (3.80 - 10.50)
Nominal (Min - Max) kCal/h 7,130 (2,580 - 9,120) 7,400 (2,580 - 9,120) 7,400 (2,580 - 9,120) 8,080 (2,920 - 9,030) 8,080 (3,270 - 9,030)
COP
1)
Nominal (Min - Max) Energy Saving
4.47 (4.08 - 5.17)
A
4.65 (5.17 - 4.08)
A
4.67 (5.09 - 4.09)
A
4.43 (5.76 - 3.30)
A
4.50 (5.31 - 3.34)
A
SCOP Nominal Energy Saving
4.00
A+
Pdesign at -10 °C kW
5.50
Power input Heating Nominal (Min - Max) kW 1.85 (0.58 - 2.60) 1.85 (0.58 - 2.60) 1.84 (0.59 - 2.59) 2.12 (0.59 - 3.18) 2.09 (0.64 - 3.14)
Annual Energy Consumption (Heating)
2)
kWh 1,925 825 825 1,065 1,055
Indoor unit
Power source V 230 230 230 230
Recommended Fuse A
Recommended power cable section mm²
Connection mm² 4 x 1.5 4 x 1.5 4 x 1.5 4 x 1.5
Current Cooling / Heating Nominal A 7.40 / 8.60 7.40 / 8.50 9.40 / 9.30 9.30 / 9.20
Air Volume Cooling m³/h 600 (E5) / 690 (E7) 690 (E7) / 712 (E12) 606 (E7) / 786 (E15) 654 (E7) / 750 (E12) 606 (E7) / 786 (E15)
Moisture removal volume l/h 1 (E5) / 1.3 (E17) 1.3 (E7) / 1.8 (E12) 0.8 (E7) / 2.3 (E15) 1.1 (E7) / 1.6 (E12) 0.8 (E7) / 2.3 (E15)
Sound pressure level
3)
Cooling & Heating (S-Lo) dB(A) 23 23 23 (E7) / 28 (E15) 23 23 (E7) / 28 (E15)
Sound power level Cooling & Heating (Hi) dB 56 56 56 56 56
Dimensions / Net weight H x W x D mm 295 x 870 x 255 / 9 295 x 870 x 255 / 9 295 x 870 x 255 / 9 295 x 870 x 255 / 9 295 x 870 x 255 / 9
Air purifier filter Nanoe-G Nanoe-G Nanoe-G Nanoe-G Nanoe-G
Outdoor unit
Air Volume Cooling / Heating m³/h 2,550 2,550 2,550 2,910 2,910
Sound pressure Level
3)
Cooling / Heating (Hi) dB(A) 48 / 49 48 / 49 48 / 49 48 / 49 48 / 49
Sound power Level Cooling / Heating (Hi) dB 62 / 63 62 / 63 62 / 63 61 / 62 61 / 62
Dimensions
4)
H x W x D mm 795 x 875 (+95) x 320 795 x 875 (+95) x 320 795 x 875 (+95) x 320 908 x 900 x 320 908 x 900 x 320
Net weight Kg 72 72 72 73 73
Piping connections Liquid pipe / Gas pipe inch (mm) 1/4 (6.35) / 3/8 (9.52) 1/4 (6.35) / 3/8 (9.52) 1/4 (6.35) / 3/8 (9.52) 1/4 (6.35) / 3/8 (9.52) 1/4 (6.35) / 3/8 (9.52)
Refrigerent Loading R410A Kg 2.64 2.64 2.64 3.1 3.1
Elevation difference (in/out)
5)
Maxm1515151515
Piping length (total) Min / Max m 60 60 60 70 70
Piping length (one unit) Min / Max m 3-25 3-25 3-25 3-25 3-25
Piping length without
refrigerant increase
Maxm3030304040
Additional gas g/m 20 20 20 20 20
Operating range Cooling Min / Max °C -10 / 46 -10 / 46 -10 / 46 16 / 43 16 / 43
Heating Min / Max °C -15 / 24 -15 / 24 -15 / 24 -20 / 24 -20 / 24
Rating Conditions: Cooling Indoor 27 °C DB / 19 °C WB. Cooling Outdoor 35 °C DB / 24 °C WB. Heating Indoor 20 °C DB. Cooling Outdoor 7 °C DB / 6 °C WB. (DB: Dry Bulb; WB: Wet Bulb)
This model is not suitable to use in heating mode below -5 °C with continuous operation (24 h operation).
Connectivity restriction: CS-E/XE_PKE units are only compatible with CU-2E15PBE, CU-2E18PBE, CU-3E18PBE, CU-4E27PBE and CU-4E27PBE outdoor units. No other outdoor unit can be connected.
1) EER and COP classification is at 230 V in accordance with EU directive 2002/31/EC. 2) The annual consumption is calculated by multiplying the input power at 230 V by an avarage of 500 hours per year in cooling mode. 3) The Sound pressure level of the units shows
the value measured of a position 1 meter in front of the main body and 0,8 m below the unit. The sound pressure is measured in accordance with Eurovent 6/C/006-97 specification. 4) Add 70 mm for piping port. 5) When installing the outdoor unit at a higher position
than the indoor unit.
Specifications subject to change without notice.
Awarded with the prestigious
IF Design Award 2013
4E7
7
P
1
2
P
E
2
(
1.
0
(1
(
5
.
(
0.
(
3.
0
(2
(
5
.
(
0.
.5
/
8
E7
E
7
)
x
8
7
e
-
G
0
4
9
6
3
x
8
7
6
.
3
IFI
A
A
PR
R
ELIMINA
AR
Y
RY D
R
D
Y
Y
R
A
A
N
N
I
M
M
ATA
TA
A
A
TA
T
A
A
L
L
E
R
P
4 - 2.47)
0 - 10.60)
580 - 9,120)
7 - 4.08)
D
8 - 2.60)
60
60
/
712
(
E12
)
712 (E1
/
1.8
(
E12
)
/ 1 8 (E12)
0
x 255
/
9
0 x 255 / 9
4E7
7
P
1
5
P
E
2
(
1
.
0
(1
(
5
(
0
.
(
3
.
0
(2
(
5
(
0
.
.5
/
8
E7
E
7
)
7
)
x
8
e
-
0
4
9
6
3
x
8
6
.
3
IFI
A
A
0
)
PR
R
ELIMINA
AR
Y
RY D
R
D
Y
Y
R
A
A
N
N
I
M
M
ATA
TA
A
A
TA
T
A
A
L
L
E
R
P
4 - 2.47)
0 - 10.60)
580 - 9,120
09 - 4.09)
D
9 - 2.59)
5
0
50
/
786
(
E15
)786 (E1
/
2.3
(
E15
)/ 2 3 (E15)
28
(
E15
)28 (E15)
0
x 255
/
9
0 x 255 / 9
4E7
7P
1
2
4
E
2
(
2
.
0
(2
(
5
(
0
.
(
3
.
0
(2
(
5
(
0
.
5
.
5
/
9
E
7
E
7
)
x
8
oe
-
0
4
9
6
2
x
9
6
.
3
WIFI
A
A
)
PR
R
ELIMINA
AR
Y
RY D
R
D
Y
Y
R
A
A
N
N
I
M
M
ATA
TA
A
A
TA
T
A
A
L
L
E
R
P
9 - 2.88)
0 - 10.50)
920 - 9,030
76 - 3.30)
D
9 - 3.18)
3
0
30
/ 750
(
E12
)/ 750 (E1
/
1.6
(
E12
)/ 1 6 (E12)
0
x 255
/
9
0 x 255 / 9
4E7
7P
15
4
E
2
(
2
0
(2
(5
(
0
(
3
0
(3
(5
(
0
5
.
5
/
9
(
E
7
E
7
)
E
7
)
x
8
oe
-
0
4
9
6
2
x
9
6
.
3
WIF
A
A
)
PR
R
ELIMINA
AR
Y
RY D
R
D
Y
Y
R
A
A
N
N
I
M
M
ATA
TA
A
A
TA
T
A
A
L
L
E
R
P
49 - 2.87)
80 - 10.50)
270 - 9,030
31 - 3.34)
D
64 - 3.14)
20
20
/ 786
(
E15
)
/ 786 (E1
/
2.3
(
E15
)
/ 2 3 (E15)
28
(
E15
)
28 (E15)
0
x 255
/
9
0 x 255 / 9
58