Datasheet
Silver Kit KIT-2XE99-PKE KIT-2XE712-PKE KIT-2XE912-PKE KIT-2XE1212-PKE
Silver Kit with Smartphone Control KIT-2XE99-PKE-WIFI KIT-2XE712-PKE-WIFI KIT-2XE912-PKE-WIFI KIT-2XE1212-PKE-WIFI
Indoor CS-XE9PKEW (x2) CS-XE7PKEW + CS-XE12PKEW CS-XE9PKEW + CS-XE12PKEW CS-XE12PKEW (x2)
White Kit KIT-2E99-PKE KIT-2E712-PKE KIT-2E912-PKE KIT-2E1212-PKE
White Kit with Smartphone Control KIT-2E99-PKE-WIFI KIT-2E712-PKE-WIFI KIT-2E912-PKE-WIFI KIT-2E1212-PKE-WIFI
Indoor CS-E9PKEW (x2) CS-E7PKEW + CS-E12PKEW CS-E9PKEW + CS-E12PKEW CS-E12PKEW (x2)
Outdoor CU-2E18PBE CU-2E18PBE CU-2E18PBE CU-2E18PBE
Cooling capacity Nominal (Min - Max) kW 4.80 (1.50 - 5.20) 5.20 (1.50 - 5.40) 5.00 (1.50 - 5.30) 5.20 (1.50 - 5.40)
Nominal (Min - Max) kCal/h 4,130 (1,290 - 4,470) 4,472 (1,290 - 4,644) 4,300 (1,290 - 4,560) 4,470 (1,290 - 4,640)
EER
1)
Nominal (Min - Max) Energy Saving
3.66 (6.00 - 3.42)
A
3.42 (6.00 - 3.42) A 3.36 (6.00 - 3.44) A
3.42 (6.00 - 3.42)
A
SEER Nominal Energy Saving 6.50
Pdesign (cooling)
5.20
Power input Cooling Nominal (Min - Max) kW 1.31 (0.25 - 1.52) 1.49 (0.25 - 1.54) 1.49 (0.25 - 1.54) 1.52 (0.25 - 1.58)
Annual Energy Consumption (Cooling)
2)
kWh 280
Heating capacity Nominal (Min - Max) kW 5.60 (1.10 - 7.20) 5.60 (1.10 - 7.20) 5.60 (1.10 - 7.20) 5.60 (1.10 - 7.20)
Nominal (Min - Max) kCal/h 4,820 (950 - 6,190) 4,820 (950 - 6,190) 4,820 (950 - 6,190) 4,820 (950 - 6,190)
COP
1)
Nominal (Min - Max) Energy Saving
4.48 (5.24 - 4.14)
A
4.63 (4.24 - 5.24) A 4.55 (5.24 - 4.19) A
4.63 (5.24 - 4.24)
A
SCOP Nominal Energy Saving
4.00
A+
Pdesign at -10 °C kW
3.80
Power input Heating Nominal (Min - Max) kW 1.25 (0.21 - 1.74) 1.30 (0.24 - 1.70) 1.23 (0.21 - 1.72) 1.21 (0.21 - 1.70)
Annual Energy Consumption (Heating)
2)
kWh 1400
Indoor unit
Power source V 230 230 230 230
Recommended Fuse A
Recommended power cable section mm²
Connection mm² 4 x 1.5 4 x 1.5 4 x 1.5 4 x 1.5
Current Cooling / Heating Nominal A 6.10 / 5.55 6.95 / 5.45 6.95 / 5.45 7.10 / 5.35
Air Volume Cooling m³/h 714 714 (E9) / 762 (E12) 606 (E9) / 654 (E12) 654
Moisture removal volume l/h 1.5 / 1.5 1.5 (E9) / 1.8 (E12) 1.4 (E9) / 1.6 (E12) 1.6 / 1.6
Sound pressure Level
3)
Cooling & Heating (S-Lo) dB(A) 23 23 23 23
Sound power Level Cooling & Heating (S-Lo) dB 56 56 56 56
Dimensions H x W x D mm 295 x 870 x 255 295 x 870 x 255 295 x 870 x 255 295 x 870 x 255
Net weight Kg 9 9 9 9
Air purifier filter Nanoe-G Nanoe-G Nanoe-G Nanoe-G
Outdoor unit
Air Volume Cooling / Heating m³/h 2214 / 2466 2214 / 2466 2214 / 2466 2214 / 2466
Sound pressure Level
3)
Cooling / Heating (Hi) dB(A) 49 / 51 49 / 51 49 / 51 49 / 51
Sound power Level Cooling / Heating (Hi) dB 64 / 66 64 / 66 64 / 66 64 / 66
Dimensions
4)
H x W x D mm 619 x 824 x 229 619 x 824 x 229 619 x 824 x 229 619 x 824 x 229
Net weight Kg 39 39 39 39
Piping connections Liquid pipe / Gas pipe inch (mm) 1/4 (6.35) / 3/8 (9.52) 1/4 (6.35) / 3/8 (9.52) 1/4 (6.35) / 3/8 (9.52) 1/4 (6.35) / 3/8 (9.52)
Refrigerent Loading R410A Kg 1.40 1.40 1.40 1.40
Elevation difference (in/out)
5)
Max m 10 10 10 10
Piping length (total) Min / Max m 30 30 30 30
Piping length (one unit) Min / Max m 3-20 3-20 3-20 3-20
Piping length without
refrigerant increase
Max m 20 20 20 20
Additional gas g/m 15 15 15 15
Operating range Cooling Min / Max °C -10 / 46 -10 / 46 -10 / 46 -10 / 46
Heating Min / Max °C -15 / 24 -15 / 24 -15 / 24 -15 / 24
Etherea with enhanced Econavi sensor and new Nanoe-G air-purifying system: outstanding
efficiency, comfort and healthy air combined with state-of-the-art design
Econavi features a Human Activity sensor and a new Sunlight Detection technology to adjust output ideally
thereby giving you the best comfort at anytime whilst saving energy. Furthermore, the Nanoe-G revolutionary
air-purifying system utilises nano technology fine particles to remove and deactivate 99% of both airborne and
adhesive micro-organisms like bacteria, viruses and mould. Etherea is more efficient than ever with 64% less
consumption for the non Inverter model on heat pump mode, and can reach 71% total savings when used with
Econavi.
Using a Multi Split 2x1 Inverter+ system with the outdoor unit CU-2E18PBE instead of 2 individual mono split
Inverter+ systems, you reduce consumption and thus save more! Up to 16%! Furthermore, using a Multi Split
system, you save space on the outdoor unit, making it easier to install in small spaces.
ETHEREA MULTI SPLIT 2x1
INVERTER+
INTERNET CONTROL READY: Optional.
A class
energy saving
Easy
control
by BMS
CONNECTIVITY
5 year
compressor
warranty
Up to 38%
energy savings
(cooling)
Air purifier
99%
removal
bacteria · virus · mold
Down to
-15 ºC in
heating mode
OUTDOOR
TEMPERATURE
Improved
comfort
AUTOCOMFORT
Internet
Control
Ready
INTERNET CONTROL
OPTIONAL
Rating Conditions: Cooling Indoor 27 °C DB / 19 °C WB. Cooling Outdoor 35 °C DB / 24 °C WB. Heating Indoor 20 °C DB. Cooling Outdoor 7 °C DB / 6 °C WB. (DB: Dry Bulb; WB: Wet Bulb)
This model is not suitable to use in heating mode below -5 °C with continuous operation (24 h operation).
Connectivity restriction: CS-E/XE_PKE units are only compatible with CU-2E15PBE, CU-2E18PBE, CU-3E18PBE, CU-4E27PBE and CU-4E27PBE outdoor units. No other outdoor unit can be connected.
1) EER and COP classification is at 230 V in accordance with EU directive 2002/31/EC. 2) The annual consumption is calculated by multiplying the input power at 230 V by an avarage of 500 hours per year in cooling mode. 3) The Sound pressure level of the units shows
the value measured of a position 1 meter in front of the main body and 0,8 m below the unit. The sound pressure is measured in accordance with Eurovent 6/C/006-97 specification. 4) Add 70 mm for piping port. 5) When installing the outdoor unit at a higher position
than the indoor unit.
Specifications subject to change without notice.
Awarded with the prestigious
IF Design Award 2013
E9P
2
E
1
(1
0
(
(6
(
0
(
1
0
(
(5
(
0
.
5
/
5
1.
x
8
oe-
4
/
51
66
x
8
6.
3
A
A
)
PRELIMINAR
ELIMINARY
TA
DA
Y DATA
A
TA
T
A
A
D
Y
R
R
A
A
N
N
I
M
M
L
L
E
R
P
Y
25 - 1.52)
0 - 7.20)
50 - 6,190)
24 - 4.14)
A
55
55
0
x
255
0 x 255
4
6
6
466
4 x 229
4 x 229
-
E
-2
0
0
3
0
0
3
6
4
9
6
0
8
2
0
5
5
2
3
0
x
1
.
9
5
/
6
(
4
(E
5
x
n
o
1
4
/
5
/
6
9
x
4
(6
40
20
E1
0)
A
A
)
5
2
)
PRELIM
E
M
M
L
L
E
R
P
I
I
NAR
RY
DA
Y DA
A
D
Y
R
R
A
A
N
N
Y
A
A
TA
TA
A
TA
T
0.25 - 1.54)
.10 - 7.20)
(950 - 6,190
5.24 - 4.19)
5
.45
5.45
9)
/ 654
(
E1
9) / 654 (E1
9)
/ 1.6
(
E12
9) / 1.6 (E12
8
7
0
x
255
870 x 255
-G
-G
2466
2466
6
6
824 x 229
824 x 229
S
-
E
U
-
2
2
0
4
7
4
2
5
2
6
0
8
2
6
3
21
30
x
1
1
0
54
6
/
3
6
95
a
n
o
2
1
4
9
/
4
/
19
9
/
4
(
4
0
0
0
-20
0
)
4
0
)
)
.
5
2
PRELIMINAR
ELIMINARY
Y
Y
R
R
A
A
N
N
I
M
M
L
L
E
R
P
Y
DA
DA
A
D
A
A
T
T
TA
TA
A
TA
0.25 - 1.58)
1.10 - 7.20)
(950 - 6,19
(5.24 - 4.24
5
5
/
5.3
5
/ 5.35
1
.
6
1.6
8
7
0
x
255
870 x 255
e
-
G
e-G
/
246
6
/ 2466
1
1
6
6
824 x 229
824 x 229
54










