Datasheet

SUPER QUIET
Silent air
22 dB
Inverter models are powerful and efficient and are always there when you need them.
WALL MOUNTED RE-3 TYPE
STANDARD INVERTER
SUPER QUIET: For RE9 and RE12
A class
energy saving
Kit KIT-RE9-PKE-3 KIT-RE12-PKE-3 KIT-RE15-PKE-3 KIT-RE18-PKE-3 KIT-RE24-PKE-3
Indoor CS-RE9PKE-3 CS-RE12PKE-3 CS-RE15PKE-3 CS-RE18PKE-3 CS-RE24PKE-3
Outdoor CU-RE9PKE-3 CU-RE12PKE-3 CU-RE15PKE-3 CU-RE18PKE-3 CU-RE24PKE-3
Cooling capacity Nominal (Min - Max) kW 2.50 (0.90-3.00) 3.50 (0.90-3.90) 4.20 (1.00-4.60) 5.00 (0.98-6.00) 6.80 (0.98-8.10)
Nominal (Min - Max) kCal/h 2,150 (770-2,580) 3,010 (770-3,350) 3,610 (860-3960) 4,300 (840-5,160) 5,850 (840-6,970)
EER
1)
Nominal (Min - Max) Energy Saving
3.57 (4.74-3.00)
A
3.47 (5.29-3.25)
A
3.33 (4.76-2.78)
B
3.40 (3.50-2.96)
A
3.24 (2.58-3.03)
A
SEER Nominal Energy Saving
5.6
A+
5.6
A+
5.6
A+
6.7
A++
5.9
A+
Pdesign (cooling)
2.5 3.5 4.2 5.0 6.8
Power input Cooling Nominal (Min - Max) kW 0.70 (0.19-1.00) 1.01 (0.17-1.2) 1.26 (0.21-1.65) 1.47 (0.28-2.03) 2.10 (0.38-2.67)
Annual Energy Consumption (Cooling)
2)
kWh 156 219 263 261 403
Heating capacity Nominal (Min - Max) kW 3.30 (0.90-4.10) 4.25 (0.90-5.10) 5.00 (0.90-6.80) 5.80 (0.98-8.00) 8.60 (0.98-9.90)
Nominal (Min - Max) kCal/h 2,840 (770-3,530) 3,660 (770-4,390) 4,300 (770-5850) 4,990 (840-6,880) 7,400 (840-8,510)
Heating capacity at -7°C Nominal kW 3.00 3.70 4.93 4.98 6.13
COP
1)
Nominal (Min - Max) Energy Saving
4.02 (5.29-3.57)
A
3.79 (6.00-3.49)
A
3.61 (4.28-2.98)
A
3.77 (2.88-3.08)
A
3.28 (2.18-3.14)
C
SCOP Nominal Energy Saving
3.4
A
3.4
A
3.4
A
4.1
A+
3.4
A
Pdesign at -10 °C kW
2.5 3.2 3.6 4.4 5.5
Power input Heating Nominal (Min - Max) kW 0.82 (0.17-1.15) 1.12 (0.15-1.46) 1.385(0.21-2.280) 1.54 (0.34-2.60) 2.62 (0.45-3.15)
Annual Energy Consumption (Heating)
2)
kWh 1029 1318 1482 1502 2265
Indoor Unit
Power source V 230 230 230 230 230
Recommended Fuse A
Recommended power cable section mm²
Connection (indoor/outdoor) mm² 4 x 1.5 4 x 1.5 4 x 1.5 4 x 2.5 4 x 2.5
Current (Nominal) Cooling / Heating A 3.3 / 3.8 4.7 / 5.2 6.0 / 6.3 6.6 / 6.9 9.6 / 11.8
Max. current A 6.3 8.4 10.5 11.4 13.9
Air Volume Cooling / Heating m³/h 750 / 666 750 / 750 822 / 870 978 / 1,074 1,104 / 1,164
Moisture removal volume l/h 1.4 2 2.4 2.8 3.9
Sound pressure Level
3)
Cooling (Hi / Lo / S-Lo) dB(A) 42 / 27 / 22 42 / 30 / 22 44 / 31 / 29 44 / 37 47 / 38
Heating (Hi / Lo / S-Lo) dB(A) 42 / 27 / 25 42 / 33 / 25 46 / 34 / 28 44 / 37 47 / 38
Sound power Level Cooling (Hi) dB 58 58 60 60 63
Heating (Hi) dB 58 58 62 60 63
Dimensions H x W x D mm 290 x 848 x 213 290 x 848 x 213 290 x 848 x 213 290 x 1,070 x 240 290 x 1,070 x 240
Net weight Kg 8 8 8 12 12
Air purifier filter
Outdoor Unit
Air Volume Cooling / Heating m³/h 1,902 / 1,842 1,956 / 1,896 1,956 / 1,956 2,352 / 2,274 3,012 / 3,012
Sound pressure Level
3)
Cooling (Hi) dB(A) 47 48 49 47 52
Heating (Hi) dB(A) 48 50 51 47 52
Sound power Level Cooling (Hi) dB 63 64 65 61 66
Heating (Hi) dB 64 66 67 61 66
Dimensions
4)
H x W x D mm 540 x 780 x 289 540 x 780 x 289 540 x 780 x 289 695 x 875 x 320 795 x 875 x 320
Net weight Kg 23 26 27 46 67
Piping connections Liquid / Gas pipe inch (mm) 1/4 (6.35) / 3/8 (9.52) 1/4 (6.35) / 3/8 (9.52) 1/4 (6.35) / 1/2 (12.70) 1/4 (6.35) / 1/2 (12.70) 1/4 (6.35) / 5/8 (15.88)
Refrigerant Loading R410A Kg 0.77 0.86 0.92 1.22 1.8
Elevation difference (in/out)
5)
Max m 10 10 10 15 20
Piping length Min / Max m 3-15 3-15 3-15 3-20 3-30
Piping length without
refrigerant increase
Maxm7777.510
Additional gas g/m 20 20 20 20 30
Operating range Cooling Min / Max °C -10 / +43 -10 / +43 -10 / +43 -10 / +43 -10 / +43
Heating Min / Max °C -15 / +24 -15 / +24 -15 / +24 -15 / +24 -15 / +24
Rating Conditions: Cooling Indoor 27 °C DB / 19 °C WB. Cooling Outdoor 35 °C DB / 24 °C WB. Heating Indoor 20 °C DB. Cooling Outdoor 7 °C DB / 6 °C WB. (DB: Dry Bulb; WB: Wet Bulb)
This model is not suitable to use in heating mode below -5 °C with continuous operation (24 h operation).
1) EER and COP classification is at 230 V in accordance with EU directive 2002/31/EC. 2) The annual consumption is calculated by multiplying the input power at 230 V by an avarage of 500 hours per year in cooling mode. 3) The Sound pressure level of the units shows
the value measured of a position 1 meter in front of the main body and 0,8 m below the unit. The sound pressure is measured in accordance with Eurovent 6/C/006-97 specification. 4) Add 70 mm for piping port. 5) When installing the outdoor unit at a higher position
than the indoor unit.
Specifications subject to change without notice.
40