Datasheet
Prevention
allergen filter
ANTI BACTERIAL
FILTER
SUPER QUIET
Silent air
22 dB
Inverter models are powerful and efficient and are always there when you need them. Furthermore, with the
Anti Bacterial Filter, you can always enjoy the best quality air, without viruses, moulds and bacteria.
WALL MOUNTED RE TYPE
STANDARD INVERTER
SUPER QUIET: For RE9 and RE12
A class
energy saving
Kit KIT-RE9-PKE KIT-RE12-PKE KIT-RE15-PKE
Indoor CS-RE9PKE CS-RE12PKE CS-RE15PKE
Outdoor CU-RE9PKE CU-RE12PKE CU-RE15PKE
Cooling capacity Nominal (Min - Max) kW 2.50 (0.90-3.00) 3.50 (0.90-3.90) 4.20 (1.00-4.60)
Nominal (Min - Max) kCal/h 2,150 (770-2,580) 3,010 (770-3,350) 3,610 (860-3960)
EER
1)
Nominal (Min - Max) Energy Saving
3.57 (4.74-3.00)
A
3.47 (5.29-3.25)
A
3.33 (4.76-2.78)
B
SEER Nominal Energy Saving
5.6
A+
5.6
A+
5.6
A+
Pdesign (cooling)
2.5 3.5 4.2
Power input Cooling Nominal (Min - Max) kW 0.70 (0.19-1.00) 1.01 (0.17-1.2) 1.26 (0.21-1.65)
Annual Energy Consumption (Cooling)
2)
kWh 156 219 263
Heating capacity Nominal (Min - Max) kW 3.30 (0.90-4.10) 4.25 (0.90-5.10) 5.00 (0.90-6.80)
Nominal (Min - Max) kCal/h 2,840 (770-3,530) 3,660 (770-4,390) 4,300 (770-5850)
Heating capacity at -7°C Nominal kW 3.00 3.70 4.93
COP
1)
Nominal (Min - Max) Energy Saving
4.02 (5.29-3.57)
A
3.79 (6.00-3.49)
A
3.61 (4.28-2.98)
A
SCOP Nominal Energy Saving
3.4
A
3.4
A
3.4
A
Pdesign at -10 °C kW
2.5 3.2 3.6
Power input Heating Nominal (Min - Max) kW 0.82 (0.17-1.15) 1.12 (0.15-1.46) 1.385(0.21-2.280)
Annual Energy Consumption (Heating)
2)
kWh 1029 1318 1482
Indoor Unit
Power source V 230 230 230
Recommended Fuse A
Recommended power cable section mm²
Connection (indoor/outdoor) mm² 4 x 1.5 4 x 1.5 4 x 1.5
Current (Nominal) Cooling / Heating A 3.3 / 3.8 4.7 / 5.2 6.0 / 6.3
Max. current A 6.3 8.4 10.5
Air Volume Cooling / Heating m³/h 750 / 666 750 / 750 822 / 870
Moisture removal volume l/h 1.4 2 2.4
Sound pressure Level
3)
Cooling (Hi / Lo / S-Lo) dB(A) 42 / 27 / 22 42 / 30 / 22 44 / 31 / 29
Heating (Hi / Lo / S-Lo) dB(A) 42 / 27 / 25 42 / 33 / 25 46 / 34 / 28
Sound power Level Cooling (Hi) dB 58 58 60
Heating (Hi) dB 58 58 62
Dimensions H x W x D mm 290 x 848 x 213 290 x 848 x 213 290 x 848 x 213
Net weight Kg 8 8 8
Air purifier filter Antiallergic filter Antiallergic filter Antiallergic filter
Outdoor Unit
Air Volume Cooling / Heating m³/h 1,902 / 1,842 1,956 / 1,896 1,956 / 1,956
Sound pressure Level
3)
Cooling (Hi) dB(A) 47 48 49
Heating (Hi) dB(A) 48 50 51
Sound power Level Cooling (Hi) dB 63 64 65
Heating (Hi) dB 64 66 67
Dimensions
4)
H x W x D mm 540 x 780 x 289 540 x 780 x 289 540 x 780 x 289
Net weight Kg 23 26 27
Piping connections Liquid / Gas pipe inch (mm) 1/4 (6.35) / 3/8 (9.52) 1/4 (6.35) / 3/8 (9.52) 1/4 (6.35) / 1/2 (12.70)
Refrigerant Loading R410A Kg 0.77 0.86 0.92
Elevation difference (in/out)
5)
Max m 10 10 10
Piping length Min / Max m 3-15 3-15 3-15
Piping length without
refrigerant increase
Max m 7 7 7
Additional gas g/m 20 20 20
Operating range Cooling Min / Max °C 16 / 43 16 / 43 16 / 43
Heating Min / Max °C -10/ +24 -10/ +24 -10/ +24
Rating Conditions: Cooling Indoor 27 °C DB / 19 °C WB. Cooling Outdoor 35 °C DB / 24 °C WB. Heating Indoor 20 °C DB. Cooling Outdoor 7 °C DB / 6 °C WB. (DB: Dry Bulb; WB: Wet Bulb)
This model is not suitable to use in heating mode below -5 °C with continuous operation (24 h operation).
Connectivity restriction: JKE units are not compatible with PKE units.
1) EER and COP classification is at 230 V in accordance with EU directive 2002/31/EC. 2) The annual consumption is calculated by multiplying the input power at 230 V by an avarage of 500 hours per year in cooling mode. 3) The Sound pressure level of the units shows
the value measured of a position 1 meter in front of the main body and 0,8 m below the unit. The sound pressure is measured in accordance with Eurovent 6/C/006-97 specification. 4) Add 70 mm for piping port. 5) When installing the outdoor unit at a higher position
than the indoor unit.
Specifications subject to change without notice.